You are here

Göz içi basınç ölçümünde hata kaynakları

The reasons of false measurement in intraocular pressure

Journal Name:

Publication Year:

Author NameUniversity of Author
Abstract (2. Language): 
false measurement of intra ocular pressure is one of the important problem of beginning appropriate diagnosis and treatment. This review we discussed the effect of false measurement in intra ocular pressure.
Abstract (Original Language): 
Göz içi basınç ölçümünde karşılaşılan hatalar uygun tanı ve tedavinin yapılmasını zorlaştıran önemli problemlerden biridir. Biz bu derlememizde göz içi basıncını etkileyen başlıca faktörleri tartıştık.
32-35

REFERENCES

References: 

1. Martin XD. Normal intraocular pressure in man. Ophthalmologica 1992;205:57-63
2. Fran Smith MA. Clinical examination ofGlaucoma. In: YanoffM, Dueker J (eds). Ophthalmology. London, Mosby 1999;12:4.1-4.3.
3. Brandt J. Congenital Glaucoma. In: YanoffM. Dueker J (eds). Ophthalmology. London, Mosby 1999; 12: 10.2-10.3.
4. Jaafar MS, Kazi GA.Effect oforal chloral hydrate sedation on the intraocular pressure measurement.J PediatrOphthalmol Strabismus 1993;30:284-287.Chatterjee A, Shah S,
5. Bessant DA, Naroo SA, Doyle SJ. Reduction in İntraocular Pressure after Excimer Laser Photorefractive Keratectomy. Correlation with pretreatment Myopia.
GİB DEĞERİ
Hatalı olarak yüksek Hatalı olarak düşük
+
Hata aralığı +
0.2-0.7
mmHg/1
0 mikrometre
+
1
mmHg / 3 diyoptri
1mmHg / 3 diyoptri 1mmHg / 4 diyoptri
1mmHg/4 diyoptri
+/- +/-
+
+
-/? -/?
++ ++
Ophthalmology 1997;104: 355-359.
6. Schipper I, Senn P, Niesen U. Do we measure the right intraocular pressure after photorefractive keratectomy.J CataractRefract Surg 1997;23:539-594.
7. Shah GB, Sharma S, Mehta AA, Goyal RK. Oculohypotensive effect ofangiotensin-converting enzyme inhibitors in acute and chronic models of glaucoma. J Cardiovasc Pharmacol. 2000 Aug;36(2):169-75.
8. Costagliola C, Mastropasqua L, Capone D, Verolino M, Ciancaglini M, Pisanti N. Effect of fluoxetine on intraocular pressure in the rabbit. Exp Eye Res. 2000 May;70(5):551-5.
9. Brath PC, MacGregor DA, Ford JG, Prielipp RC. Dopamine and intraocular pressure in critically ill patients. Anesthesiology. 2000 Dec;93(6):1398-400.
10. Fragen RJ, Hauch T. The effect ofmidazolam maleate and diazepam on intraocular pressure in adults. Arzneimittelforschung. 1981;31(12a):2273-5.
11. Brody S, Erb C, Veit R, Rau H. Intraocular pressure changes: the influence ofpsychological stress and the Valsalvamaneuver. Biol Psychol. 1999 Oct;51(1):43-
57.
12. dos Santos MG, Makk S, Berghold A, Eckhardt M, Haas A. Intraocular pressure difference in Goldmann applanation tonometry versus Perkins hand-held applanation tonometry in overweight patients. Ophthalmology. 1998 Dec;105(12):2260-3.
13. Qureshi IA. Does physical fitness influence intraocular pressure? J Pak Med Assoc. 1997 Mar;47(3):81-4.
14. Christophe C, Marc-Antoine C, Anne Pavy LT, Catherine M, Claude G, Philippe D. Changes in Intraocular Pressure during Prolonged (7-Day) Head-DownTiltBedrest. JournalofGlaucoma. 12(3):204-208,June2003.
15. Qureshi IA. Intraocular pressure and pregnancy: a
S.D.Ü. Tıp fak.
Derg
. 2006:13(3)/ 32-35
Tığ, Göz içi basınç ölçümünde hata kaynakları
35
comparison between normal and ocular hypertensive subjects. Arch MedRes. 1997 Autumn;28(3):397-400.
16. Dan L. Eisenberg, Brian G. Sherman, Craig A. McKeown and Joel S. Schuman Tonometry in adults and children : A manometric evaluation of pneumatonometry, applanation, and TonoPen in vitro and in vivo.Ophthalmology, Volume 105, Issue 7, 1 July 1998,Pages1173-1181
17. Marc M. Whitacre and Richard Stein Sources oferror with use ofGoldmann-type tonometersESurvey of Ophthalmology, Volume 38, Issue 1, July-August 1993, Pages 1-30