Analyzing and Modeling the Lightning Transient Effects of 400 KV Single Circuit Transmission Lines

Journal Name:

Publication Year:

Abstract (2. Language): 
Nowadays over voltages caused by lightning in transmission line located in mountainous regions are very important in power system transient studies. This study aims to present and investigate modeling 400 KV single circuit transmission lines. Hence this study, the performed analysis for assessing single phase ignition and back flash over, three common models of the tower in transient studies including Multistory, simplified Multistory and simplified wide line models have been used. The paper illustrates the benefit of ATP / EMTP to finding the best type of line against the lightning. The paper has proven that for negative polarity of current wave, range of overvoltage caused by lightning is the lowest for the Multistory model, Moreover the paper considering the same negative polarity, range of voltages from arms to earth is the lowest for Multistory model. Also results of this study show that Multistory is better and more acceptable than the other two models for the studied line.
FULL TEXT (PDF): 
61-67

REFERENCES

References: 

[1] S.E. Naghib, S. Najafi, S.A. Sajadi, “Sub transmission system tower model for lightning surge over voltage analysis” In: PSC of 21th Power System Conference, pp. 1856-1863.
[2] Ito, T. Ueda, T. Watanabe, H. Funabashi, T. Ametani, “A. Lightning flashovers on 77-kV systems: observed voltage bias effects and analysis” IEEE Transactions on Power Delivery, Vol. 18, pp. 545-550, April 2003.
[3] M. Ishii, T. Kawamura, T. Kouno, O. Eiichi, K. Shiokawa, K. Murotani, T. Higuchi, “Multistory transmission tower model for lightning surge analysis” IEEE Transactions on Power Delivery, Vol. 6, pp. 1327–1335, Jul 1991.
[4] N. Nagaoka, “A development of frequency dependent tower model” IEE Transactions on Japan, Vol. B-111, pp. 51–56, Jul 1991.
[5] T. Hara, O. Yamamoto, M. Hayashi, T. Nagai, “Modelling of a transmission tower for lightning-surge analysis” IEE Proc.-Cener. Transm. Distrib., Vol. 143, pp. 283-289, Ma y 1996.
[6] J.W. Woo, J.S. Kwak, H.J. Ju, H.H. Lee, J.D. Moon, “The analysis results of lightning over voltages by EMTP for lightning protection design of 500 kV substation” In: IPST International Conference on Power Systems
Transients, June 2005, pp. 1-5.
[7] T. Ueda, M. Yoda, I. Miyachi, “Characteristics of lightning surges observed at 77 kV substations” Electrical Engineering in Japan, Vol. 124, pp. 40-48, August 1998.
[8] T. Ueda, S. Neo, T. Funabashi, T. Hagiwara, H. Watanabe, “Flashover model for arcing horns and transmission line arresters” In: IPST’95 International Conference on Power System Transients, September 1995, pp. 328–333.
[9] P.C.A. Mota, M.L.R. Chaves, J.R. Camacho, “ Power line tower lightning surge impedance computation, a comparison of analytical and finite element methods” In: ICREPQ’12 International Conference on Renewable Energies and Power Quality, March 2012, pp. 1-6.
[10] K.L. Cummins, E.P. Krider, M.D. Malone, “The US national lightning detection networkTM and applications of cloud-to-ground lightning data by electric power utilities” IEEE Transactions on Electromagnetic Compatibility, Vol. 40, pp. 465-480, Nov 1998.

Thank you for copying data from http://www.arastirmax.com