Buradasınız

PULSE-DTMF ARAMA TABANLI BİNA GÜVENLİK SİSTEMİ TASARIMI VE UYGULAMASI

DESIGN AND IMPLEMENTATION OF BUILDING SECURITY SYSTEM BASED ON PULSE-DTMF

Journal Name:

Publication Year:

Keywords (Original Language):

Abstract (2. Language): 
In this study, a control unit has been designed and implemented using Pulse and DTMF calling methods together. The developed control set has been used to declare alarm status and taking measures in a building security system. The designed system is based on an Atmel microprocessor which is programmed in Assembly language. The control unit determines calling method and performs the calling operation using a calling circuit. The alarm status is announced the registered numbers in system by means of sending messages according to the alarm type.
Abstract (Original Language): 
Bu çalışmada, Pulse ve DTMF arama metotlarının birlikte kullanılmasına yönelik bir kontrol seti tasarlanmış ve uygulaması gerçekleştirilmiştir. Geliştirilen kontrol seti bir bina güvenlik sisteminde alarm durumunun bildirilmesi ve önlemlerin alınması için kullanılmıştır. Tasarımda, assembly dilinde programlanan bir Atmel mikroişlemci kullanılmıştır. Kontrol ünitesi arama yöntemini belirler ve tasarlanan devre ile arama işlemi gerçekleştirilir. Sistemde kayıtlı numaralara, alarm tipine uygun mesajlar gönderilerek alarm durumu bildirilir.
423
428

REFERENCES

References: 

Cerberus, 1996.
"Genera
l Fire Detection System Planning", Novak Koruma Hizmetleri, İstanbul.
Davidsson, P., Magnus, B. 2000. "A Mülti-agent System for Controlling Intelligent Buildings" In Proceedings of 4th International Conference on Multi-Agent System, USA, 377-378.
Dexter, A. L., Trewhella, D. W. 1990. Building Control Systems: Fuzzy Rule-based Control and Performance Assesment, Building Services Eng. Res. and Technology, 11 (4), 115-124.
Göktas,
H.
, Daldal, N. 2005. A Cellular Phone
Based Home/Office Controller & Alarm System, G.U. Journal of Science.
Gürdal, O. 2000. Algılayıcılar ve Dönüştürücüler, Nobel Yayınevi, Ankara.
Lee, C. F., Xu, Y. P. 2001. "Theoretical study on a New Multi-Sensor Systems" Sensor for Industry
Conference, USA, 187-191.
Lee, K.S., Lee, S., Oh, K.T. and Baek, S. M. 2002.
Network Configuration Technique for Home
Appliances", Proceedings of ICCE 2002, vol. 1, 180-181.
Pfister, G. 1991. Trends Toward the Optimum Danger Dedection System, Security Technology, Proceedings 25 th Annual 1991, IEEE International Carnahan Conference, pp. 253-260.
Sharples, S., Vic, C., Graham, C. 1999. A multi-agent architecture for intelligent building sensing and control, Sensor Review, 19 (2), 135-140.
Zeljko, J. A. 2000. "Minimization of The Optical Smoke Detector False Alarm Probability By Optimizing Its Frequency Charasteristic" IEEE Transactions On Instrumentation and Measurement, 37-42 February 2000, Vol. 1, 49.

Thank you for copying data from http://www.arastirmax.com