Determination of Noise Level During Hazelnut Harvesting with The Pneumatic
Hazelnut Harvester
Journal Name:
- International Journal of Agriculture and Wildlife Science
Key Words:
Keywords (Original Language):
Author Name | University of Author | Faculty of Author |
---|---|---|
Abstract (2. Language):
In this study, during hazelnut harvesting with the pneumatic hazelnut
harvester noise level values were determined, and its noise map have been
prepared. It was determined that in addition to machine and machine to work
within three meters (respectively; 105.70, 96.70, 93.80 and 91.70 dB(A)) noise level
was over the limit values of the national and international standards, and the
possible measures to be taken were discussed. Since the noise levels were
obtained after three meters away from the machine were lower than the value
being allawed by national and international standards, it was determined that
there was no need to make a noise control study.
Bookmark/Search this post with
Abstract (Original Language):
Bu çalışmada fındık hasadı sırasında pnömatik fındık toplama makinasının
oluşturduğu gürültü düzeyi değerleri tespit edilmiş ve çalışma alanındaki gürültü
haritası hazırlanmıştır. Gürültü ölçümü yapılan pnömatik fındık toplama
makinasının yanında ve makinaya üç metre mesafe içerisinde çalışmak (sırasıyla;
105.7, 96.7, 93.8 ve 91.7 dB(A)) ulusal ve uluslararası standartlarda verilen gürültü
sınır değerlerinin üzerinde olduğu belirlenmiş ve alınabilecek önlemler tartışılmıştır.
Makinadan üç metre uzaklaştıktan sonra elde edilen gürültü düzeyleri, ulusal ve
uluslararası standartlarda izin verilen değerin altında olduğundan, herhangi bir
gürültü kontrolü çalışmasına gerek olmadığı tespit edilmiştir.