OPTIMIZATION OF HEAT EXCHANGER
CLEANING CYCLE ON A SHIP
Journal Name:
- Journal of Naval Sciences And Engineering
Keywords (Original Language):
Author Name | University of Author |
---|---|
Abstract (2. Language):
Fouling of heat exchangers causes the thermal-hydrolic performance of
heat-transfer equipment to decrease with time. When the thermal hydrolic
performance decreases to a minimum acceptable level, the heat exchanger
has to be cleaned. The decision regarding periodic cleaning of the heat
exchangers is generally based on thermoeconomic performance of the
process. In this paper, coolant and seawater temperatures through seawater
cooled shell and tube during 2500 operating hours have been measured
and total fouling resistances have been founded. The dimensionless cost
model and variation with the dimensionless time is examined by considering
the various cost elements for the seawater cooled shell and tube heat
exchanger.
Bookmark/Search this post with
Abstract (Original Language):
Isı değiştiricilerde birikinti, ısıl hidrolik performansının zamanla
azalmasına neden olmaktadır. Isıl hidrolik performans minumum bir kabul
edilebilir seviyeye geldiğinde ısı değiştiricinin temizliğini n yapılması zorunludur. Isı değiştiricinin periyodik temizlik kararı için, genellikle
prosesin termoekonomik performansı esas alınmaktadır. Bu çalışmada,
2500 işletme saati süresince deniz suyu soğutmalı gövde borulu ısı
değiştiricide dolaşan soğutma suyu ve deniz suyu akışkanlarının sıcaklıkları
ölçülmüş ve toplam birikinti dirençleri bulunmuştur. Bir gemi ana
makinesinin deniz suyu soğutmalı ısı değiştiricisi için çeşitli maliyet
elemanları değerlendirilerek boyutsuz maliyet modeli ve boyutsuz zaman ile
değişimi incelenmiştir.
- 1