You are here

POLlMERÎZASYON FARKLILIĞI GÖSTEREN AKRİLİKLERİN BOYUTSAL STABİLİTE AÇISINDAN KARŞILAŞTIRILMASI

THE COMPARISON OF THE DIMENSIONAL STABILITY OF ACRYLICS SHOWING POLYMERIZATION DIFFERENCES

Journal Name:

Publication Year:

Abstract (2. Language): 
The purpose of this investigation is to compare dimensional stability of acrylic resins polymerized by conventional system, injection moulding technique and microwave energy, Lineer measuremen t method was used for dimensional stability test. For th\s purpose a metal master model, simulating the shape of an edentulous upper arch was prepared. After 24 hours and 28 days, the measurements were made fabricated on these models. The statistically significant difference amoung all groups after 24-hours, lost its importance for the conventional and injection specimens immersed in water for 28 days. When all the results are considered as a whole, it can be concluded that acrylic' resin poJymerization technique using microwave energy has the advantages of processing simplicity is time consuming, economic and can be accepted as an alternative to the conventional methods.
Abstract (Original Language): 
Araştırmada, konvansiyon e] yöntem, enjeksiyonla kalıplama tekniği ve mikrodalga enerjisi île polimerize o]an akrilik rezinlerin boyutsal stabilite açısından incelenerek karşılaştırmalarının yapılması amaçlanmıştır. Boyutsal stabilite testlerinde lineer ölçüm yöntemi kullanılmıgtır. Bunun için üst çene modeline benzeyen, ancak basamaklı bir yapı gösteren metal master model hazırlanmıştır. Alç] modeller ve bunlar üzerinde hazırlanan kaide plaklarında 24 saat ve 28 gün sonra ölçümler alınmıştır. İstatistiksel olarak ilk 24 saat sonunda tüm gruplar arasında görtiîen anlamlı farklılık 28 günlük su emilimi sonunda konvansiyonel ve enjeksiyon »işlemleri arasındaki önemini yitirmiştir. Bulgularımız bir bütün olarak clc alındığında, mikrodalga enerjisi ile polimerize edilen akrilik rezinin zaman ve işlem kolaylığının yanı sıra ekonomik açıdan avantajlı bir materyal olduğu ve konvansiyonel yönteme karşı bir alternatif alarak kabul ediîebiicceği düşünülmektedir.
21-25

REFERENCES

References: 

1. Anderson
GC
» Schulte JKt Arnold TG. Dimensional stability of injection and conventional processing of denture base acrylic resin. J Prosthet Dent 1988; 60; 394-8.
2. Baemmert RJ, Language BR, Barco MT, Billy EL The effects of denture teeth on the dimensional accuracy of acrylic resin denture bases. Int J Prosthod 1990; 3; 528-37.
3. Breeding LC, Dixon DL, Lund PS, Dimensional changes of processed denture based after relining with three resins. J Prosthet Dent 1991; 66: 650-6.
4. Craig RG, Peyton FA. Restorative Dental Materials. 5th ed.CV Mosby Comp, St Louis, 1975; 397.
5. De Clerck JP. Microwave polymerization of arcyiic resins usw iri dcfiîâî prostheses. J Prosthet Dent 1987; 57(5): 650-8.
' 6. Dukes BS, Fields H, Olson JW, Scheetz JP. A laboratory study of changes in vertical dimension using a compression molding and a pour resin technique, J Prosthet Dent 1985; 53: 667-9.
7. Garfunkel E. Evaluation of dimensional changes in complete dentures processed by injection-pressing and the pack-and-press technique. J Prosthet Dent 1983; 50: 757-61.
8. Goodkind RJ, Schulte RC. Dimensional accuracy of pour acrylic resin and conventional processing of cold-curing acrylic resin bases. J Prosthet Dent 1970; 24: 662-8.
9. Huggett R, Brooks SC,. Bates JF. The effect of different curing cycles on the dimensional accuracy of acrylic resin denture base materials. Quint Dent Tech 1984; 8; 81-5.
10. Huggett R, Zissis A, Harrison Av Dennis A. Dimensional accuracy and stability of acrylic resin denture bases. J Prosthet Dent 1992; 68: 634-40.
11.
Kalıpçıla
r B, Karaağaç!toğlu L, Hasanreisoğlu U, DenEi N. Protezlerde kullanılan farklı iki kaide materyalinin boyutzal stabilite açısından değerlendirilmesi. G Ü Diş Hek Fak Derg 1989; VE: [71-87.
12. Mac Gregor AG, Graham J, Stafford GDf Huggett R. Recent experiences with denture polymers. J Dent 1984; 12: 146-57.
13. Mowery WE, Dickson G, Swemy WT. Dimensional stability of denture base resins. J Am Dent Assoc 1958; 57: 345-53.
14. Nishii M- Studies on the curing of denture base resins with microwave irradiation: With particular reference to heat-curing resing. J Osaka Dent Univ 1968; 2; 23-40.
24
Atatürk Üniv.Diş Hck.Fak.Derg. Cilt:6 Sayr.2 Sayfa: 21-25,1996
KESKİN, KARAAĞAÇLJOĞLU
15. Phillips RW, Swaitz MJ, Norman RD. Materials for the practicing dentist, CV Mosby Comp, St Louis, 1969.
16. Polyzois GL, Karkazis HC, Zissis AJ, Demetriou PP. Dimensional stability of dentures processed in boilable acrylic resins: A comparative study. J Prosthet Dent 1987; 57; 639-47.
17. Salim S, Sadamori S, Hamada T, The dimensional accuracy of rectangular acrylic resin specimens cured by three denture base processing methods. J Prosthet Dent 1992; 67: 879-81,
18. Sanders JL, Levin Bv Reitz PV. Comparison of the adaptation of acrylic resin cured by microwave energy and conventional water bath. Quint Tnt 1995; 22: 181 -6.
19. Shlosberg SR, Goodacre CJ, Munoz CA, Moore KB, Schnell RJ. Microwave energy polymerization of poly (methyl methacrylate) denture base resin. Int J Prosthod 1989; 2:453 S.
20. Takamata T, Arakawa H,. Inoue Y, Sugitou S, Kunta K,Kurasawa I. Hashimoto K. Dimensional accuracy of acrylic resin denture bases. Literature Rewiew-MatsEimotoShigaku 1989; 15: 555-62.
21. Takamata T. Setcos JC, Phillips RW, Boone ME. Adaptation of acrylic resin dentures as influenced by activation mode of polymerization. J Am Dent Assoc 1989; 119: 271-6.
22. Takamata T, Setcos JC, Phillips RW, Boone ME. Adaptation of acrylic resin dentures as influenced by the activation mode of polymerization J Am Dent Assoc 1989; 119: 271-6.
23. Wallace PW, Graser Gn, Myers ML, Proskin HM. Dimensional accuracy of denture resin cured by microwave energy. J Prosthet Dent 1991; 66: 403-7.

Thank you for copying data from http://www.arastirmax.com