You are here

KOK KANALI ÇALIŞMA UZUNLUĞUNUN TESPİTİNDE ÜÇ KLİNİK METODUN DOĞRULUĞUNUN DEĞERLENDİRİLMESİ

EVALUATION OF THE ACCURARY OF THREE CLINICAL METHOD IN DETERMINATION OF THE WORKING LENGTH OF ROOT CANAL

Journal Name:

Publication Year:

Abstract (2. Language): 
The accurate determination of root canal length and identifying the point of apical termination in the success of endodontic theraphy is of indisputable importance. It is widely accepted that root canal preparation and filling should be terminated at the cemento-dentinal junction, which has been defined as the most apical site of the dental pulp. In this study, the efficiacy of the three clinical method used (Electronic apex locator Neosono-D , Digitale Tactile Senses and Radiographic measurements) for location physilogical foramen of teeth were investigated. Three different methods were used before extraction to determine working length in 34 single rooted of 25 patients. The results were then compared with postextraction working length measurements. The determinations were made after eliminating the canal contents and drying the interior. The values gained for three method were compared the actual values using the t tests for paired samples. The results showed that only Digitale Tactile Senses method had the statistically significant difference at the 95 % confidence level with(p<0, 05).
Abstract (Original Language): 
Kök kanal uzunluğunun doğru olarak tesbit edilmesi ve apikal sınır noktasının tayin edilmesi, endodontik tedavinin başarısında şüphesiz önemlidir. Kök kanal preparasyon ve dolgusunun, dental pulpanın en apikal yeri olarak bilinen dentino-semantal birleşimde sonlandırılması gerektiği yaygın olarak kabul edilir. Bu çalışmada, dişlerin fizyolojik forameninin lokali-zasyonu için kullanılan üç klinik metodun (Elektronik apeks lokatör Neosono-D, Digitale Tactile Senses ve Ra-dyografik ölçüm metodu) etkinliği incelendi. Üç farklı met-od 25 hastanın 34 tek köklü dişlerinde çalışma uzunluğunu çekim öncesi tesbit etmek için kullanıldı. Sonuçlar, çekim sonrası çalışma uzunluğu ölçümleriyle karşılaştırıldı. Tespit işlemleri kanal muhteviyatı ve kanal içi rutubet elimine edildikten sonra yapıldı. Üç metodla elde edilen değerler, eşleştirilmiş t testi kulllanılarak gerçek değerlerle karşılaştırıldı. Sonuçlar, sadece digital tactile senses metodunun %95 seviyede (p<0, 05)istatistiki olarak önemli olduğunu gösterdi.
42-47

REFERENCES

References: 

1. Basting
G
. Konservatif diş hekimliği ; kök kanalı anatomisi ve tedavisi. TD Qintessenz 1986; 11:977-981.
2. Berman LH, Fleischman SB. Evaluation of the accurary of the Neosono-D Electronic apex locator. J of End 1984(4);10:164-67.
3. Burch JG, Hulen S. The relationship of the apical foramen to the anatomic apex of the tooth root. Oral Surg 1972;34(2):262-66.
4. Czervv RJ, Fulkerson MS, Donnelly JC, Walmann JO. In Vitro Evaluation of the accurary of several electronic apex locators. J of End 1995,21(11):572-75.
5. Dalat
D
, Zıraman F. Kök kanal uzunluğunun teshirinde yeni bir yöntem. A. Üni Diş Hek. Fak Derg 1987;14(2):187-190.
6. Frank AL, Torabinejad M. An invivo evaluation of endex electronic apex locator. J of End 1993; 19(4): 177¬82.
7.
Gençoğl
u N, Günday M. Kök kanal uzunluğunun tayininde Neosono-D ve Formatron IV adlı iki apex lo-katörün doğruluğunun incelenmesi. Selçuk Üni. DişHek. Fak. Dergl993;3(l):l-3.
8. Hembrough JH, Weine FS, Pisano JV, Eskoz N. Accurary of an electronic apex locator; A Clinical evaluation in maxillary molars. J of End 1993;19(5):242-5.
9. Inoue N, Skinner H. A Simple and accurate way of measuring root canal length. J of End 1985; 11(10):421 -24.
10.
Karagöz-Küçüka
y I, Küçükay S. Endo analyzeifJ in klinik açıdan etkinliği ve güvenilirliği. Diş Hekimliğinde Klinik 1993;1:5-10.
11. Kaufman AY, Szajkis S, Niv N. The efficiency and reliability of the Dentometer for detecting root canal length. Oral Surg 1989;67(5):573-7.
12. Kobayashi C, Suda H. New electronic canal measuring device based on the ratio method. J of End 1994;20(3):111-114.
13. Kobayashi C. Advantages an disadvantages of electronic canal measurement. Oral Surg 1995 ;79(2):227-231.
46
Atatürk Üniv.Diş Hek.Fak.Derg.
Cilt:9, Sayırl, Sayfa:42-47,1999
AYDEMİR, SEVEN, YILMAZ
14. Larheim TA, Eggen S. Determination of tooth length with a standardized paralelling technique and calibrated radiographic measuring film. Oral Surg 1979;48 (4):374-378.
15. Lehr WN, Marsh RA,. A radiographic study of the point of endodontic egress. Oral Surg 1973;35(1):105-110.
16. Mayeda DL, Simon JHS, Aimar DF, Finley K. In Vivo measurement accurary in vital and necrotic canals with the endex apex locator. J of End 1993;19(11):545-8.
17. Olson AK, Goerig AC, Cavatio RE, Luciano J. The ability of the radiography to determine the location of the apical foramen. Int End J 1991 ;24:28-35.
18. O'Neill LJ, Captain DC. A Clinical avaluation of electronic root canal measurement. Oral Surg 1974;38 (3):469-72.
19. Seidberg BH, Alibrandi BV, Fine H, Logue B. Clinical investigation of measuring working lengths of root canals with an electronic device and with digital-tactile sense. JADA 1975;90:379-82.
20. Stabholz A, Rotstein I, Torabinejad M. Effect of preflaring on tactile detection of the apical constriction. J of End 1995;21(2):92-95.
21. Ushiyama J. Reliability and safety of the voltage gradient method of root canal measurement. J of End 1984;10(ll):532-6.
22. Vande Voorde HE, Moline 111, Bjorndahl AM. Estimating endodontic'working lengthD with parelelling radiographs. Oral Surg 1969;27(l):106-9.