EXPERIMENTALLY AND ANALYTICAL INVESTIGATION OF AXIALLY LOADED TIED COLUMNS WITH AND WITHOUT STEEL FIBERS
Journal Name:
- Dokuz Eylül Üniversitesi Mühendislik Fakültesi Fen ve Mühendislik Dergisi
Keywords (Original Language):
Author Name | University of Author | Faculty of Author |
---|---|---|
Abstract (2. Language):
In this study, the behaviour of axially loaded columns with and without steel fibers was
investigated experimentally and analytically. In the experimental part, 18 rectangular
reinforced concrete columns were tested under the axial load. Load carrying capacity and
axial load-strain relationships of the specimens were obtained. In the analytical part,
mathematical models (Saatcioglu and Ravzi, Sheikh and Uzumeri, Modified Kent and Park)
which were derived for axially loaded column were investigated. In addition, the analytical
solution which uses these mathematical models was carried out. Experimental and analytical
results were compared and obtained results were discussed.
Bookmark/Search this post with
Abstract (Original Language):
Bu çalışmada, eksenel yük altındaki çelik lifli/fiberli ve lifsiz/fibersiz etriyeli betonarme
kolonların davranışı, hem deneysel hem de analitik olarak incelenmiştir. Deneysel bölümde
18 adet dikdörtgen kesitli etriyeli betonarme kolon eksenel yük altında test edilmiştir. Deney
numunelerinin taşıma güçleri ile eksenel yük-boyuna birim kısalma ilişkisi elde edilmiştir.
Analitik çalışmada ise, malzeme için geliştirilmiş olan matematiksel modellerden Saatcioğlu
ve Ravzi, Sheikh ve Üzümeri ile Geliştirilmiş Kent ve Park Modelleri ayrıntılı bir şekilde ele
alınmış, hesap esasları verilmiştir. Ayrıca, söz konusu bu matematiksel modeller kullanılarak
deney numunelerinin analitik çözümü yapılmıştır. Elde edilen deneysel ve analitik sonuçlar
karşılaştırılarak irdelenmiştir.
FULL TEXT (PDF):
- 1
65-85