You are here

Manyetik Rezonans Görüntüleme Ünitesindeki Pediyatrik Olgularda Anestezi Deneyimlerimiz

Our Anesthetic Experience in Pediatric Cases Underwent Magnetic Resonance Imaging

Journal Name:

Publication Year:

Abstract (2. Language): 
Due to the recent improvements in technologic and pharmacologic fields, invasive and non-invasive diagnostic and/or therapeutic approaches are increasingly used outside the operative rooms. The anesthetists should be incorporated and share the responsibility in order to increase the success rates and patient safety, on performing these procedures. In this study, we aimed to present the used anesthetic techniques and the resultant complications, during October 2002-December 2006 in MR scanning unit for the pediatric cases by our clinic. 1458 pediatric cases were included in the study. We experienced cardiac arrest in three and minor complications such as bradycardia (45), desaturation (98), and prolonged sedation (22) in 168 of these cases. The anesthetists must be more careful when working outside the operating room. In addition, we believe that the anesthetists should be more active in regulating the physical and technical infrastructure, for patients who will receive anesthesia outside the operating room in order to maintain the safety of the patient and the medical personnel.
Abstract (Original Language): 
Günümüzde, teknolojik ve farmakolojik gelişmeler sayesinde, hastalara tanı ve tedavi amacıyla ameliyathane dışı ortamlarda invaziv ve invaziv olmayan girişimler artarak uygulanmaya başlanmıştır. Bu girişimlerde başarı oranının artırılması ve hasta güvenliğinin sağlanması için anestezistlere görev düşmektedir. Bu çalışmada Ekim 2002-Aralık 2006 tarihleri arasında manyetik rezonans görüntüleme ünitesinde kliniğimizce pediyatrik olgulara uygulanan anestezi tekniklerini ve ortaya çıkan komplikasyonları sunmayı amaçladık. Çalışmaya 1458 pediyatrik olgu dahil edildi. Bu olgulardan üçünde kardiyak arrest sonucu eksitus, 168 olguda ise minör komplikasyonlar ile karşılaşıldı bunlar; bradikardi, (45) desatürasyon (98) ve uzamış sedasyon (22) şeklindeydi. Anestezistler ameliyathane dışı ortamlarda görev yaparken komplikasyonlardan kaçınılması için normalden daha dikkatli olmak zorundadır. Ayrıca anestezi verilecek ameliyathane dışı ortamlarda hasta ve personel güvenliğini sağlamak için gereken fiziki ve teknik altyapının düzenlenmesinde anestezistlerin aktif görev almaları gerektiği kanısındayız.
239-243

REFERENCES

References: 

1. Türk Anesteziyoloji ve Reanimasyon Derneği (TARD) Anestezi Uygulama
Klavuzları. Ameliyathane Dışı Anestezi Uygulamaları 2005; Kasım
2. http://www.asahq.org/publicationsAndServices/standards/14.pdf,
3. Morgan GE, Mikhail MS, Murray MJ. Klinik Anesteziyoloji 4.baskı. Ankara
2008: 925.
4. Malviya S, Voepel-Lewis T, Eldevik OP, Rockwell DT, Wong JH, Tait AR.
Sedation and general anaesthesia in children ndergoing MRI and CT; adverse
events and outcomes. Br. J Anaesth 2000; 84: 743-8.
5. Gooden CK. Anesthesia for magnetic resonance imaging. Current Opinion in
Anaesthesiology 2004; 17: 339-42
6. Malviya S, Voepel-Lewis T, Tait AR. Adverse events and risk factors
associated with the sedation of children by non-anesthesiologist. Anesth Analg
1997; 85: 1207-13.
7. Voepel LT, Malviya S, Prochaska G, Tait RA. Sedation failures in children
undergoing MRI and CT: is temperament a factor? Paed Anaesth 2000; 10: 319-
23.
8. Cengiz M, Baysal Z, Ganidagli S. Oral sedation with midazolam and
diphenhydramine compared with midazolam alone in children undergoing
magneticresonance imaging. Paediatr Anaesth. 2006; 16:621-6.
9. Wilson C. Who should perform pediatric endoscopic sedstion? Pediatr
Gastroenterol Nutr. 1994: 18; 114
10. Koroglu A, Teksan H, Sagir O, Yucel A, Toprak HI, Ersoy OM. A
comparison of the sedative, hemodynamic, and respiratory effects of
dexmedetomidine and propofol in children undergoing magnetic resonance
imaging. Anesth Analg. 2006 Jul;103(1):63-7
11. Aypar Ü, Pamuk AG. Girişimsel radyoloji ve anestezik yaklaşım. Anestezi
Dergisi 2007; 15: 149-160.

Thank you for copying data from http://www.arastirmax.com