DÜZENSİZ BATIN VE PELVİS SAHALARINA KOBALT-60 İLE RADYOTERAPİ UYGULAMALARINDA KORUMA BLOKLARININ DOZ PARAMETRELERİNE ETKİSİ

The Effects of Shielding Blocks On Dose Parameters During Cobalt-60 Irradiation Of The Irregular Abdomen And Pelvis Fields

Journal Name:

Publication Year:

Abstract (2. Language): 
Shielding blocks for protection of vital organs within a radiation field give rise to changes in dose distribution of open field due to decreased scattered radiation from the shielded areas. Several methods have been used to calculated depth dose values for irregular fields. However, vaiidity of such methods should be verified before routine use in ciinic. In this study, measured percentage depth doses for selected irregular abdomen and pelvis fields have been compared with percentage depth dose for fields obtained using equivalent squares (negative field) and [4x(A/P)] techniques. Dose rates for blocked and unblocked fields have been measured. Also, dose profles for open fields at 0.5 cm and blocked fields for three depths -0.5, 5 and 10 cm depth - have been obtained and the effect of blocking on dose profle for open field has been investigated. Yazışma Adresi Y. Doç . Dr. Murat BAŞ Yüzüncü Yıl Üniversitesi Tıp Fakültesi, Radyasyon Onkolojisi AD 65200-VAN Tel : 432 216 2329 Faks: 432 216 7519 E-Mail: muratbas@ixir.com When measured percentage DD for the selected fields were compared with percentage DD for equivalent squares technique,the percentage difference were found 1.38 % and 1.47 % since the block edge was close to central axis. When measured percentage DDs were compared with percentage DD for [4x(A/P)] technique, the percentage difference were found 1.08 % and 1.21 % for the abdomen and pelvis fields respectively. But both techniques were convenient for percentage DD except points at block edge. When out-put values for selected blocked fields were compared with those of open fields, if blocked fields were less than 25 %, out-put of open fields could be used for irregular fields. The dose under the block for selected field was about 10 % of dose at d max.
Abstract (Original Language): 
Radyoterapide kritik organların korunması amacıyla radyasyon alanı içine konulan bloklar, korunmuş saha kısımlarından radyasyon saçllmasını azaltarak, açık alanın doz dağıhmlarının değişmesine neden olurlar. Düzensiz alanların derin doz % değerlerinin bulunmasına ilişkin çeşitti metodlar geiiştirlmiştir. Ancak, rutinde kullanllan bu metodların ölçümlerle geçeriiiiğinin incelenmesi gerekiidir. Bu çahşmada çeşitti düzensiz alanların ölçülen derin doz % değerleri, kare eşdeğeri (KE-negatif alan) ve [4x(A/P)] yöntemiyle bulunan alanların E derin doz değerler lle karşllaştırllmış, bloklu ve açık alan doz verimler ölçülmüştür. Ayrıca üç deriniikte (0.5, 5 ve 10 cm deriniikler için) açık ve bloklu alanların doz profllerr çizdirilmiş ve bloklamanın açık alan doz profiine olan etkisi incelenmiştir. Seçllen batın ve pelvis düzensiz alanlarında yapllan DD % ölçümleri lle negatif alan (KE) yöntemiyle bulunan alanların DD % değerler arasında %1.38 ve %1.47 oranında fark ortaya çıkmıştır. Ölçülen D D % değerleri lle [4x (A/P)] yöntemiyle bulunan alanların DD % değerler %1.08 ve %1.21 olarak saptanmıştır. Her iki hesaplama yöntemi de blok kenarındaki noktalar hariç DD % değerleri için uygun ölçüm metodu olarak kabui edllmiştir. Ancak, her kiiniğin kendi hesaplama yöntemini kendi koşullarında beiirmesi uygun olacaktır. Seçllen bloklu alanlar lle açık alanların doz verimleri mukayese edlldiğinde bloklamanın % 25den az olduğu vakalarda açık alan (koiimatör) doz veriminin kullanllablleceği görülmüştür. Bu çahşmada kullanllan alanlarda blok altındaki dozlar, tüm alanlar için dmax'ın % 10'u civarındadır.
301-307

REFERENCES

References: 

1. IAEA Absorbe dose determination in photon and electron beam. An International code of Practice Technical Reports Series No: 277, Vienna (1987).
2. Agarwall SK, Wakley J, Scheele RV, Normansell A A method of dosimetry for irregularly shaped fields, Int Radiat Oncol Biol Phys 1977;2: 199-203.
3. Aral IM, Cail D, Nissel M, Spira J Dosimetry of irregular fields in cobalt 60 therapy, Acta Radiol Ther Phys Biol 1970;9: 24-32.
4. Anderson R, D'angio GJ, Khan FM Dosimetry of irregularly shaped radiation therapy fields, Radiol 1969;92: 1092-1100.
5. Khan FM Dosimetry of irregularly shaped fields in Levitt and Tapley's Technological Basis of Radiation Therapy: Practical Clinical Applications S.M.Levitt; F. M. Khan; R. A. Potish. Lea > Febiger. 1992;73-79.
6. Johns HE, Cunningham JR Equivalent squares and circles for rectangular and irregular fields in the Physics of Radiology 4.Edition Charles C: Thomas, Sprinfield îllionois, chapter 1983;10:356 -358.
7. Clarkson JR A note on depth doses in fields of irregular shape, Brit.J.Radiol. 1941;14:265-268.
8. Wrede D, Tai D, Edwards F, Coffey C, Schroader K An intercomparison between two methods of obtaining percentage depth doses for irregular
shaped fields and comparison of each method with experimental data for Co-60 and 10 MV X-rays, Brit.J. Radiol. 1979;52 (1,2): 398-404.
9. Brown LH, Swensson GK, Bjarngard BE Day's integration of scatter dose with an analytical expression, Med Phys 1981;8(2): 184-189.
10. Khan FM Computer dosimetry of partially blocked fields in cobalt teletherapy, Radiol 1970;97:405-411.
11. Page V, Gardner A, Karzmark CJ Physical and dozimetric aspects of the radiotherapy of malignant lymphomas, Radiol 1970;96:619-626.
12. Davis JB, Reiner B Depth dose under narrow sheilding blocks: a comparison of measure and calculated dose, Radiother Oncol 1995;34:
19- 7.
13. ICRU 23 Measurement of absorbed dose in a phantom irradiated by a single beam of X or gamma rays, (1973).
14. Shahabi S Irregularly Shaped Fields. Blackbum's Introduction to Clinical Radiation Therapy Physics, Medical Physics Wisconsin 1989;12: 141¬15 .
15. Bukovitz AG Computer calculation of dose for irregularly shaped field for Co-60 and 6 MV photons, Radiol 1974;113:181-185.
16. Fontenla DP, Kutcher GJ, Losasso TJ: Simulating blocks in treatment plaiming calculations, Int Radiat Onco Biol Phys 1989;16: 867-873.
17. Bilge H.,
Teki
n M., Hamidkhou N.: Co-60 ile yapılan çalışmalarda düzensiz (bloklanmış) radyasyon alanlarının merkezi eksenlerinde % derin doz tayinleri, Türk Onkoloji Dergisi 1995;10: 35-38.
18. Tatcher M., Bjarngard B. E.: Equivalent squares of irregular photon fields, Med Phys 1993;20(4): 1229-1232

Thank you for copying data from http://www.arastirmax.com