Partial Discharge Localization in Stator Winding of Generators using Multi-Conductor Transmission Line Model

Journal Name:

Publication Year:

Abstract (2. Language): 
Partial discharges (PDs) are a major source of insulation failure in power generators. Techniques for locating a PD source are of major importance in both the maintenance and repair of a generator. In this paper a wide band MTL model of generator winding employed to best simulate propagation of partial discharge signals in generators and precisely locate the source of partial discharge in the winding. The MTL model is briefly reviewed and the related equations of the model are reformulated to easily simulate application of a PD signal at any location along the winding. Using Matlab software is developed to calculate the windings resonance frequencies and the magnitudes of over voltages occurring between different coils along the winding. Comparing these results with the experimental results, accuracy of this model and the related simulation is verified. Propagation of PD signal in a high voltage generator (6kv/250kw) is simulated using the Multi-Conductor transmission line (MTL) model with frequency dependent parameters.
FULL TEXT (PDF): 
51-55

REFERENCES

References: 

[1] The Study of PD Propagation Phenomenon in Power Network,IEEE TRANSACTIONS ON POWER DELIVERY, VOL. 21, NO. 3, JULY 2006, Qin Shaozhen and S. Birlasekaran, Senior Member, IEEE.
[2] A. MazhabJafari, A. Akbari, “Partial discharge localization in transformer windings using multi-conductor transmission line model”, Electric Power Systems Research, Vol. 78, Issue 6, June 2008, pp. 1028-1037.
[3] S. M. H. Hosseini, M. Ghaffarian, M. Vakilian, G. B. Gharehpetian, F.Forouzbakhsh,”partial dischage location in transformer through
application of MTL model”R. E. James, B. T. Phung, Q. Su, ‘Applicationof Digital Filtering Techniques to the Determination of Partial Discharge Location inTransformers’, IEEE Trans. Electrical Insulation,Vol. 24, No.4, August, 1989.
[4] Yafei Zhou, A. I. Gardiner, G. A. Mathieson,Y. Qin, ‘New Methods of Partial DischargeMeasurement for the Assessment and Monitoringof Insulation in Large Machines’, p111-114.
[5] Z.D. Wang, P.A. Crossley, K. J. Cornick, ‘ASimulation Model for Propagation of PartialDischarge Pulse in Transformer’, p151-155,1998.
[6] Xuzhu Dong, Deheng Zhu, Changchang Wang,Kexiong Tan, Yilu Liu, ‘Simulation ofTransformer PD Pulse Propagation and Monitoringfor 500kV Subsation’, IEEE Trans. On Dielectricand Electrical Insulation, Vol.6, No.6, Dec. 1999,p803-813.
[7] Z.D. Wang, P. A. Crossley, K. J. Cornick,‘Partial Discharge Location in Power TransformersUsing the Spectra of the Terminal CurrentSignals’, High Voltage Engineering Symposium,IEE, p5.58.s10-5.61.s10, Aug., 1999.
[8] P. Werle, A. Akobari, H. Borsi, E.Gockenbach, ‘Partial Discharge Localisation onPower Transformers Using Neural NetworksCombined with Sectional Winding TransferFunctions as Knowledge Base’, p579-582.
[9] R.H. Middleton, G.C. Goodwin, DigitalControl and Estimation, Prentice Hall, EnglewoodCliffs, N.J., 1990.
[10] T. Back, D.B. Fogel, Z.MichalewiczEvolutionary Computation 1: Basic Algorithm andOperators, Institute of Physics Publishing, Bristoland Philadelphia, 1984.
[11] James S. Walsh, Graham C. Goodwin,Frequency Localising Basis Functions for Wide bandIdentification, 2003.
[12] Lawrence P.Huelsman, Basic ElectricalTheory.
[13] Francisco de Leon, Adam Semlyen, CompleteTransformer Model for ElectromagneticTransients, IEEE Transactions on Power Delivery,Vol.9, No.1, Jan.1994, p231-237.
[14] G.B.Gharehpetian, H.Mohseni, K.Moller, Hybrid Modelling of Inhomogeneous Transformer Windings for Very Fast Transient Over-voltage Studies, IEEE Trans. On Power Delivery, Vol.13, No.1, January 1998, p157-163.

Thank you for copying data from http://www.arastirmax.com