You are here

Effect of Thread Design of Orthodontics Mini Implants on Their Stability - A Pilot Study

Journal Name:

Publication Year:

Abstract (2. Language): 
Objectives- This FEM study was conducted in order to investigate the effect of thread design of an orthodontic mini-implant on primary stability and strain pattern and magnitude in the surrounding bone structure during orthodontic loading. Materials and Methods- The mini-implants by six different manufacturers such as Aarhus Mini-Implant (American Orthodontics), AbsoAnchor (Dentos), Dual-Top (Jeil Medical), LOMAS (Mondeal), IMTEC Mini Ortho Implant (IMTEC), tomas (Dentaurum) were placed in porcine jaw bone segments and they were subjected to micro CT scan. FE model was constructed using program system MSC. Marc/Mentat. The load of 400 grams was gradually applied. In each case we determined the deflection of the implant head as well as the distribution of strain in the cortical and cancellous bone. To investigate the effect on stability, the resulting force/deflection ratios were calculated. One way ANOVA test was used to analyze the correlation between resulting bone strain and thread depth and thread edge. The resulting strain was ranging from 324 for to 2000 (Aarhus 9.6X2 and Abs anchor 10.5x1.4, respectively). No statistically difference was found for all the mini implants in relation to thread edge (P>0.05). However statistically difference was found between the thread depth (p<0.05) where the mini implants with deeper thread showed more strain than that with less depth. Even the strain for all the implants was within the physiological limits, mini implants with deeper thread showed more bone strain than the with less depth. No statistic difference was found between the mini implant with sharp and blunt edges.
24
28

REFERENCES

References: 

[1] Chen F, Terada K, Hanada K, Saito I. Anchorage effects of a palatal osseointegrated implant with different fixation: A Finite Element Study. Angle Orthod 2005;75:593–601.
[2] Thresher RW, Saito GE. The stress analysis of human teeth. J Biomech 1973;6:443-449.
[3] Borchers L, Reichart P. Three dimensional-dimensional stress distribution around a dental implant at a different stages of interface development. J Dent Res 1983;62:155-159.
[4] Clelland NL, Ismail YH, Zaki HS, Pipko D. Three dimensional finite element stress analysis in and around the screw-vent implant. Int J Max Implant 1991;6:391-398.
[5] Geng JP, Tan KBC, Liu GR. Application of finite element analysis in implant dentistry; a review of literature. J Prosth Dent 2001;85:585-598.
[6] Tanne K, Sakuda M, Burstone CJ. Three-dimensional finite element analysis for stress in the periodontal tissue by orthodontic forces. Am J Orthod Dentofacial Orthop 1987;92:499–505.
[7] McGuinness JNP, Wilson AN, Jones ML, Middleton J. A stress analysis of the periodontal ligament under various orthodontic loadings. Eur J Orthod 1991;13:231–242.
[8] Rahimi A, Keilig L, Bendels G, Klein R, Buzug TM, Abdelgader I, Abboud M, Bourauel C. 3D Reconstruction of dental specimens from 2D histological images and μCT-scan. Comp Meth Biomech Biomed Eng 2005;8:167-176.
[9] Jones ML, Hickman J, Middelton J, Konex J, Volp C. A Validated finite element method study of orthodontic tooth movement in the human subject. J Orthod 2001;28: 29-38.
[10] Isidor F. Influence of forces on peri-implant bone. Clin Oral Implants Res 2006;17:8–18.
[11] Frost HM. A 2003 update of bone physiology and Wolff‘s Law for clinicians. Angle Orthod 2004;74:3–15.
[12] Frost HM. Wolff’s law and bone’s structural adaptations to mechanical usage an overview for clinicians. Angle Orthod 1994;64:175-88
International Journal of Science and Engineering Investigations, Volume 5, Issue 50, March 2016 28
www.IJSEI.com Paper ID: 55016-05
ISSN: 2251-8843
[13] Stahl E, Keilig L, Abdelgader I, Jäger A, Bourauel C. Numerical analyses of biomechanical behavior of various orthodontic anchorage implants. J Orofac Orthop 2009;70:115-27.
[14] Gracco A, Cirignaco A, Cozzani M, Boccaccio M, Pappalettere C, Vitale G. Numerical/experimental analysis of the stress field around miniscrews for orthodontic anchorage. Eur J Orthod 2009;31:12–20.
[15] Dalstra M, Cattaneo PM, Melsen B. Load transfer of miniscrews for orthodontic anchorage. Orthodontics 2004;1:53-62.
[16] Motoyoshi M, Inaba M, Ono A, Ueno S, Shimizu N. The effect of cortical bone thickness on the stability of orthodontic mini-implants and on the stress distribution in surrounding bone. Int J Oral Maxillofac Surg 2009:38:13-8.
[17] Motoyoshi M, Inaba M, Ueno S, Shimizu N. Mechanical anisotropy of orthodontic mini-implants. Int J Oral Maxillofac Surg 2009:38:972-7.
[18] Fongsamootr T , Seehawong N , Buranastidporn B. Three-dimensional finite element analysis of the effect of miniscrew implant length on
stress distribution in the miniscrew and cortical bone. Journal of Biomechanics 2006;39:S565.
[19] Geramy A, Morgano SM. Finite elements analysis of three designs of implant-supported molar crown. J Pros Dent 2004;92:434-40.
[20] Chun, H.J., Cheong, S.Y., Han, J.H., Heo, S.J., Chung, J.P., Rhyu, I.C., Choi, Y.C., Baik, H.K., Ku, Y. & Kim, M.H. (2002) Evaluation of design parameters of osseointegrated dental implants using finite element analysis. Journal of Oral Rehabilitation 29: 565–574.
[21] Motoyoshi M, Yano S, Tsuruoka T, Shimizu N. Biomechanical effect of abutment on stability of orthodontic mini-implant. A finite element analysis. Clin Oral Implants Res 2005;16:480-5.
[22] Lin CL, Yu JH, Liu HL, Lin CH, Lin YS. Evaluation of contributions of orthodontic mini-screw design factors based on FE analysis and the Taguchi method. J Biomech. 2010; 43: 2174-81.

Thank you for copying data from http://www.arastirmax.com