HATALI RESTORASYON PLANLAMASINA BAĞLI BALL ATAŞMAN VİDA KIRIĞI VAKASI

Ball Attachment Screw Fracture Case Due to False Restoration Planning

Journal Name:

Publication Year:

Abstract (2. Language): 
Screw fracture is one of the mechanical complications that occur in implant restorations. This is a situation that generally arises after screw loosening depending on metal fatigue. There are plenty of factors that lead to screw loosening. As for this case, a series of complications that come along due to an inaccurate implant placement on the opposing jaw causes screw fracture of a ball attachment. After the fractured screw specimen was extracted with endodontic files, an ultrasonic cavitron and a probe for common examination without detriment to the screw hole, a new ball attachment was applied to the implant. Because of financial insufficiencies and an ongoing cervical discal hernia treatment, patient didn't want to have additional implants in her maxilla and new prostheses. Also she didn't want to replace ball attachments with locator attachments which used in cases that show limited vertical height. For this reasons existed prostheses was made available for usage then delivered to the patient. Screw loosening is a more recognized complication then screw fracture. A loose screw that is not retightened would be fractured. Adequate treatment planning, well arranged of abutment screw loosening and fracture. occlusal contacts and screw tightening with correct torque value will minimize the incidence.
Abstract (Original Language): 
Vida kırığı implant restorasyonlarında görülen mekanik komplikasyonlardan biridir. Çoğunlukla vida gevşemesini takiben metal yorgunluğuna bağlı olarak ortaya çıkan bir durumdur. Vida gevşemesine neden olabilecek pek çok faktör bulunmaktadır. Bu vakada ise karşıt çenede hatalı şekilde konumlanmış bir implantın neden olduğu bir dizi komplikasyon sonucunda ball ataşman vidası kırılmıştır. Kırık vida parçası kanal eğeleri, ultrasonik kavitron ve bir muayene sondu yardımıyla vida yuvasına zarar vermeden çıkarılmış, yeni bir ball ataşman implanta bağlanmıştır. Hasta maddi durumunun yetersiz olması ve boyun fıtığı tedavisi görüyor olması sebebiyle üst çeneye ilave implantlar yapılmasını, ball ataşmanların - dikey boyutun sınırlı olduğu vakalarda kullanılan - locator tutucularla değiştirilmesini ve yeni protezlerin yapımını reddetmiştir. Bu sebeplerle mevcut protezler kullanılabilir hale getirilip hastaya teslim edilmiştir. Vida gevşemesi, vida kırığından daha sık meydana gelen bir komplikasyondur. Gevşeyen vida sıkılmadığı takdirde kırılabilir. Uygun tedavi planlaması, iyi düzenlenmiş oklüzal temaslar ve vidanın doğru tork kuvvetiyle sıkılması, vida gevşemesi ve kırığının görülme sıklığını azaltacaktır.
53
58

REFERENCES

References: 

1. Kreissl ME, Gerds T, Muche R Hey¬decke G, Strub JR. Technical complications of implant-supported fixed partial dentures in partially edentulous cases after an average observation period of 5 years. Clin Oral Impl Res, 2007; 18: 720-26.
2. Pjetursson BE, Tan K, Long NP, Bragger U, Egger M, Zurahlen M. A systematic review of the survival and complication rates of fixed partial dentures (FPDs) after an observation period of at least 5 years—I. Implant-supported FPDs. Clin Oral Implants Res, 2004; 15: 667-76.
3. Jung RE, Pjetursson BE, Glauser R, Zembic A, Zwahlen M, Lang NP. A systematic review of the 5-year survival and complication rates of implant-supported single crowns. Clin Oral Impl Res, 2008; 19: 119-30.
4. Schwarz MS. Mechanical complications of dental implants. Clin Oral Impl Res, 2000; 11 (Suppl.): 156-58.
5. McGlumphy EA, Mendel DA, Hol-loway JA. Implant screw mechanics. Dent Clin N Am, 1998; 42: 71-89.
6. Winkler S, Ring K, Ring JD, Babe-rick KG. Implant screw mechanics and the settling effect: Overview. J Oral Implantol,
2003; 29(5): 242-45.
7. Mericske-Stern RD, Taylor TD, Bel-ser U. Management of the edentulous pati¬ent. Clin Oral Impl Res, 2000; 11 (Suppl.): 108-25.
8. Jivraj S, Chee W, Corrado P. Tre¬atment planning of the edentulous maxilla.
British Dental Journal, 2006; 201: 261-79.
9. Schneider AL, Kurtzman GM. Restoration of divergent free-standing implants in the maxilla. J Oral Implantol, 2002; 28:
113-16.
10. Nguyen CT, Masri R, Driscoll CF,
58
Hatalı Restorasyon Planlamasına Bağlı Ball Ataşman Vida Kırığı Vakası
Romberg E. The effect of denture cleansing solutions on the retention of pink Locator attachments: An in vitro study. J Prosthodont, 2010; 19(3): 226-30.
11.
Goodacr
e CJ, Bernal G, Rungcha-rassaeng K, Kan JYK. Clinical complications with implants and implant prostheses. J Prosthet Dent, 2003; 90: 121-32.
12.
Luterbache
r S, Fourmousis I, Lang NP, Bragger U. Fractured prosthetic abutments in osseointegrated implants: A technical complication to cope with. Clin Oral Impl Res, 2000; 11: 163-70.
13. Nergiz İ,
Schmag
e P, Shahin R. Removal of a fractured implant abutment screw: A clinical report. J Prosthet Dent, 2004; 91: 513-17.
14.
Misc
h CE, çev. Kutay Ö. Dental implant protezler. İstanbul: Nobel Tıp Ki-tabevleri, 2009, s. 206-27.
15.
Garbe
r DA, Belser UC. Restoration-driven implant placement with restoration-generated site development. Compend Contin Educ Dent, 1995; 16(8): 796, 798¬802, 804.

Thank you for copying data from http://www.arastirmax.com