POWER SYSTEM SERIES HARMONIC RESONANCE ASSESSMENT BASED ON IMPROVED MODAL ANALYSIS

Journal Name:

Publication Year:

Abstract (2. Language): 
Harmonic resonances in the grid network, both the parallel resonance and the series resonance, have been given more and more attention in modern power system operation and study. The modal analysis approach that based on the node impedance matrix has shown a promising way for the parallel resonance assessment in recent years. With regard to the series resonance, a novel approach, combining the modal analysis and the dummy branch method, is proposed in this paper to compute the series resonance frequency and the corresponding branch information. It is found here that the loop impedance matrix should be used in assessing the series resonance problem rather than the node impedance matrix that we used in assessing the parallel resonance. It is also illuminated that since the network topology changes constantly when analyzing the series resonance phenomenon, the dummy branch method should be embedded into this approach. The tests results and practical application show the correctness and effectiveness of this method. The results of this paper can serve as a parallel approach which can provide more sufficient information of harmonic resonance than the conventional widely used frequency scan analysis do, and this can also be used for the checkout of resonance frequency of filters.
423-430

REFERENCES

References: 

[1] J. Arrillaga, C. N. Watson, Power System
Harmonics, John Wiley & Sons Ltd, New
York, 2003.
[2] CEA Technology Inc., “Impact of
Harmonics on Utility Equipment: A Survey
and Review of Published Work”, Tech.
rep., Rep. No: T024700-5117, 2003.
[3] IEEE Harmonics Model and Simulation
Task Force, “Modeling and Simulation of
the Propagation of Harmonics in Electric
Power Networks: Part I”, IEEE Trans. on
Power Delivery, Vol: 11, no: 1, pp. 452-
465, Jan. 1996.
[4] B. C. Smith, J. Arrillaga, A. R. Wood, et
al., “A review of Iterative Harmonic
Analysis for AC-DC Power Systems”,
IEEE Trans. Power Delivery, Vol: 13, No:
1, pp. 180-185, 1998.
[5] W. Xu, Z. Huang, Y. Cui, et al.,
“Harmonic Resonance Mode Analysis”,
IEEE Trans. on Power Delivery, Vol: 20,
No: 2, pp. 1182-1190, Apr. 2005
[6] Z. Huang, Y. Cui, W. Xu, “Application of
Modal Sensitivity for Power System
Harmonic Resonance Analysis”, IEEE
Trans. on Power Systems, Vol: 22, No: 1,
pp. 222-231, Feb. 2007.
[7] A. G. Adly, M. F. Christopher, C. P. Jay
and et al., “Harmonics and Transient
Overvoltages Due to Capacitor Switching”,
IEEE Trans. on Industry Applications, Vol:
29, No: 6, pp. 1184-1188, Nov, 1993.
[8] R. Bellman, Introduction to Matrix
Analysis, 2nd Edition. McGraw-Hill Inc,
New York, 1970.
[9] M. Ai, Z. Cao, Y. Zhang, et al., “Research
on the Amplified Harmonic Current in the
Capacitor Circuit of Guihua Transformer
Substation”, Water Resources and Power,
Vol: 16, No: 4, pp. 67-71, 1998 (in
Chinese) .
HUI ZHOU, is a Ph.D. candidate in Huazhong University of Science and Techlonogy, Wuhan, China. His
research interests include power system harmonic analysis, power system planning, analysis and control, and
power market.

Thank you for copying data from http://www.arastirmax.com