You are here

Design and System Development of a New On-line Recycled Water Clean-up Technology

Journal Name:

Publication Year:

Abstract (2. Language): 
Based on the stir and separation, a new method is put forward to clean the deposit in sedimentation pool. Using the similarity theory in the design of experiment rig simulated a sedimentation tank clean-up system. The rationality of developing the industrial recycled water clean-up system was verified by theoretical analysis and numerical simulation (CFD) and the method to test “3D” research problems in the laboratory PIV flow field. In order to ensure the accuracy of the verification, the numerical simulation and PIV experimental model were designed at the ratio of 1:1. Results indicate that the mixture coefficient of muzzle is about 0.7;in different pressure conditions. The fluid boundary which spouted from combing tube can be regarded as a line and it has same angle with the combing tube. Experiment data also indicate that water speed is below 0.1 m/s on top of muzzle 1m zone. Axial velocity of fluid spouted from muzzle is measured and empirical formula is put forward. The best distance is 200mm between muzzles which determined by experiment, which ensures the level of clear water at the upper layer of the sedimentation tank, meeting the demand for industrial water.
FULL TEXT (PDF): 
1-6

REFERENCES

References: 

[1] Chunlei ZHANG, Mingjing CHEN, Peiwei LI, et al. Clean-up of the Industrial Recycled Water System without Machine Halt [J]. Henan Electric Power, 2001, 25(2): 18-19
[2] Qiong FENG, Qiuhong ZHANG, Pingping FENG, et al. Evaluation and Treatment Scheme of Industrial Recycled Water Operation [J]. Rubber and Plastic Technology and Equipment, 2009, 35(8): 45-50.
[3] Fujun WANG. Application of CFD to turbulent flow analysis and performance prediction hydraulic.Mechanical [J]. Journal of China Agricultural University, 2005, 10(4): 75-80.
[4] Rennian LI, Qiuhong WANG, Jianfemg SHEN, et al. Numerical Simulation of Solid/liquid Two-phase Flow in the Screw Centrifugal Pump [J]. Fluid Machinery, 2008, 12(36): 24-27.
[5] Qiuhong WANG. Within the screw centrifugal pump solid-liquid two-phase flow field of the CFD simulation [D]. Lan Zhou: Lanzhou University of Technology, 2005.
[6] Nabavi M. Invited Review Article: Unsteady and pulsating pressure and temperature: A review of experimental techniques [J]. Review of Scientific Instruments. 2010, 81(0311013).
[7] Nabavi M, Siddiqui K. A critical review on advanced velocity measurement techniques in pulsating flows [J]. Measurement Science&Technology. 2010, 21(0420024).
[8] Heitz D, Memin E, Schnorr C. Variational fluid flow measurements from image sequences: synopsis and perspectives [J]. Experiments In Fluids. 2010, 48(3): 369-393.
[9] Wereley S T, Meinhart C D. Recent Advances in Micro-Particle Image Velocimetry [J]. Annual Review Of Fluid Mechanics. 2010, 42: 557-576.
[10] Hongwu TANG, Limo TANG, Hong CHEN, et, al. Fluid Measurement Technology and Application [M]. Beijing: Science Press, 2009.