You are here

Lif ve çimento türünün sifcon özeliklerine etkisi

Effect of fiber and cement type on sifcon properties

Journal Name:

Publication Year:

DOI: 
10.5505/pajes.2015.94547
Abstract (2. Language): 
Slurry infiltrated fiber concrete (SIFCON) with advanced engineering properties which appear as open source product development of coming years, is used as precast concrete products in places requiring explosion and high temperature resistance. In this study, properties of SIFCON produced with various fiber and binder materials were investigated. In two different length of steel and polypropylene fiber were used in order to investigate the effect of fiber. In the binder phase Portland cement, pozzolanic cement, calcium aluminate cement, and fly ash were used. At the end of the test results that conducted on prismatic specimens, the effect of fiber and binder type determined with discussing the changes in unit weight, ultrasonic pulse velocity, bending strength, compressive strength, water absorption of SIFCON. In generally, it was observed that the binder type is effected the SIFCON properties. Using steel fiber was more proper than the other fiber due to improve the properties of SIFCON. Macro fibers have been more effective to improve the macro properties.
Abstract (Original Language): 
İleri mühendislik özellikleri ile de önümüzdeki yılların gelişmeye açık ürünü olarak karşımıza çıkan çimento bulamacı emdirilmiş lifli beton (SIFCON), patlama ve yüksek sıcaklığa dayanıklılık gerektiren yerlerde, prekast ürünlerde kullanılmaktadır. Bu çalışmada farklı lif ve bağlayıcılarla üretilen SIFCON’nun özelikleri araştırılmıştır. Lifin etkisini araştırmak amacı ile iki farklı boyda çelik ve polipropilen lifler kullanılmıştır. Bağlayıcı fazında ise Portland çimentosu, ,puzolanlı çimento, kalsiyum alüminatlı çimento, uçucu kül kullanılmıştır. Üretilen prizmatik numuneler üzerinde yapılan deneyler sonucu bağlayıcı ve lif türünün etkisi, birim ağırlık, ultrases geçiş hızı, eğilme dayanımı, basınç dayanımı, su emme değişimler irdelenerek belirlenmiştir. Genel olarak bağlayıcı türünün SIFCON özeliklerini etkilediği görülmüştür. Çelik lif kullanılması özelikleri geliştirdiği için daha uygundur. Makro özelikleri iyileştirmede makro lifler daha etkili olmuştur.
400
404

REFERENCES

References: 

[1] Rao HS, Ghorpade VG, Ramana NV, Gnaneswar K. “Response of SIFCON two-way slabs under impact loading”. International Journal of Impact Engineering, 37, 452-458, 2010.
[2] Yalçınkaya Ç, Beglarigale A, Yazıcı H, Yiğiter H. "Yüksek sıcaklığın SIFCON'un direncine etkisi". THBB Beton 2013 Hazır Beton Kongresi Bildirileri, İstanbul, Türkiye, 21-23 Şubat 2013.
[3] İpek M, Canbay M, Yılmaz K. “Çelik ve polipropilen liflerin yalın ve kombinasyonlu olarak kullanılmasının SİFCON'un mekanik ve fiziksel özelliklere etkisi”. SAÜ Fen Bilimleri Dergisi, 19(1), 41-52, 2015.
[4] Nanni A. “Properties of aramid-fiber reinforced concrete and SIFCON”. Journal Materials in Civil Engineering, 4(1), 1-15, 1992.
[5] Farnam Y, Moosavi M, Shekarchi M, Babanajad SK, Bagherzadeh A. “Behaviour of slurry infiltrated fibre concrete (SIFCON) under triaxial compression”. Cement and Concrete Research, 40(11), 1571-1581, 2010.
[6] Ipek M, Aksu M, Yılmaz K, Uysal M. “The effect of pre-setting pressure on the flexural strength and fracture toughness of SIFCON during the setting phase”. Construction and Building Materials, 66, 515–521, 2014.
[7] Tuyan M, Yazıcı H. “Pull-Out behavior of single steel fiber from SIFCON matrix”. Construction and Building Materials, 35, 571–577, 2012.
[8] Abdollahi B, Bakhshi M, Mirzaee Z, Shekarchi M, Motavalli M. “SIFCON strengthening of concrete cylinders in comparison with conventional GFRP confinement method”. Construction and Building Materials, 36, 765–778, 2012.
[9] Yazıcı H, Yiğiter H, Aydın S, Baradan B. “Autoclaved SIFCON with high volume class C fly ash binder phase”. Cement and Concrete Research, 36(3), 481-486, 2006.
[10] Yazıcı H, Aydın S, Yiğiter H, Yardımcı M, Alptuna G. “Improvement on SIFCON performance by fiber orientation and high-volume mineral admixtures”. Journal of Materials in Civil Engineering, 22(11), 1093–1101, 2010.
[11] Jain S, Kumar G. “Effect of fiber volume and partial replacement of cement by GGBS on flexural strength of SIFCON”. International Journal of Engineering Research and Technology, 4(6), 268-269, 2015.
[12] Balaguru P, Kendzulak J. “Flexural behavior of slurry infiltrated fiber concrete (SIFCON) made using condensed silica fume”. International Concrete, 91, 1215-1230, 1986.
[13] Yalçınkaya Ç, Beglarigale A, Yazıcı H. “The effect of metakaolin and end type of steel fiber on fiber-SIFCON matrix bond characteristics”. Uşak University Journal of Material Sciences, (3)1, 97-105, 2014.
[14] Korucu H, Gulkan P. “High-Velocity impact of large caliber tungsten projectiles on ordinary Portland and calcium aluminate cement based HPSFRC and SIFCON slabs. Part I: experimental investigations”. Structural Engineering and Mechanics, 40(5), 595-616, 2011.