In this study, it is aimed to the determination of required shear wall ratio for shear wall-frame systems
as regards to local site class. This for 7 and 9 stories reinforced structures are designed in 1st earthquake area,
I=1 building seismic importance factor. Analysis of designed structures is performed according site classes for
local soil profiles defined in DBYBHY-2007 (Specifications for the Buildings to be Constructed in Earthquake
Areas, 2007). Story drifts are determined according to story displacements calculated from the analysis and
compared with interstory drift capacity specified in Turkish earthquake code. Thus, required shear walls ratio are
determined for each local site class as regards building area.
Bookmark/Search this post with
Abstract (Original Language):
Bu çalışmada, zemin sınıfına göre perdeli-çerçeveli sistemler için gerekli perde oranının belirlenmesi
amaçlanmıştır. Bu amaçla 1. deprem bölgesinde, I=1 bina önem kat sayısına sahip, 7 ve 9 katlı betonarme yapılar
tasarlanmıştır. Tasarlanan yapıların analizleri DBYBHY–2007 (Deprem Bölgelerinde Yapılacak Binalar
Hakkındaki Yönetmelik–2007)’de belirtilen zemin sınıflarına göre yapılmıştır. Çözümlerden elde edilen kat yer
değiştirmelerine göre göreli kat ötelemeleri belirlenmiş ve deprem yönetmeliğindeki sınır değer ile karşılaştırılmıştır.
Böylelikle, her bir zemin sınıfı için yapıların alanına göre gerekli perde oranları tespit edilmiştir.