Abstract (2. Language): 
In this study, appropriate empirical formulations have been developed for the high frequency behaviour of subscriber cables manufactured in accordance with Turkish PTT Specifications. Primary parameters found by theoretical calculations for 0.4 mm, 0.5 mm, 0.6 mm and 0.9-mm diameters PD-PDA and PDF type cables with copper conductors have been compared with experimental results and frequency bands where theoretical calculations deviate by less than 2-3% from experimental results have been determined. Finally 0-10 Mhz range has been divided into five frequency sub-bands and band boundaries for eight types of filled and unfilled local telephone cables have beeen obtained.
Abstract (Original Language): 
Bu çalışmada, Türk PTT’sinin “Ses Frekans Dağıtım Kabloları Teknik Şartnamesi”ne göre üretilip şehiriçi telefon şebekesine döşenen kabloların yüksek frekans parametreleri incelenmiş, teorik hesaplamaların pratik ölçmeler ve deney sonuçlarıyla ne derece bağdaştığı araştırılmış ve gerektiğinde formüllere düzeltme faktörü eklenmiştir. Şehiriçi telefon şebekesinde kullanılan 0.4 mm, 0.5 mm, 0.6 mm ve 0.9 mm çapında bakır telli PD-PDA ve PDF tipi kablolarda teorik hesaplamalarla bulunan kablo birincil parametreleri, deney sonuçları ile kıyaslanmış, formüllerin %2 veya %3’den küçük bir hata ile geçerli olduğu frekans bandları tespit edilmiştir. 0-10 MHz frekans bölgesi 5 alt frekans bandına bölünmüş ve telefon şebekesine döşenen 8 tip dolgulu ve dolgusuz kablo için band sınırları belirlenmiştir.
11-26

REFERENCES

References: 

1. Belevitch, V. (1978) Capacitance of Circuts in a Tight Screened Pair or Quad, Philips Journal of Research, 33
(3/4), 139-148.
2. Gürkaynak, E. (1982) Notiz über Rechenformel für die Betriebskapazitat, Siemens - KLN, NKEKB 12, Berlin.
3. Heinz, W. (1978) Unterlagen für WKM Vien über Betriebskapazitatsberechnungen Siemens - KLN, NKE 121,
Berlin.
4. Kaden, H. (1959) Wirbelströme und Schirmung in der Nachrichtentechnik, Springer - Verlag, Berlin, Götingen,
Heidelberg.
5. Megla, G. (1962) Dezimeterwellentechnik, Berliner Union, Stuttgart.
6. Mitchell, D.M. (1988) The Effect of Filling Compound on the Capacitance of Foam - Skin Insulation, Labaratory
Simulation vs. Cable Performance, 37th International Wire & Cable Symp., 627 – 636.
7. Normann, H. (1982) Rechenformel für Betriebskapazitaten, KLN – Siemens, Berlin.
8. Riley, E. ve Acuna, V. (1990) Transmission Systems, ABC of the Telephone, vol. 8, 11-19.
9. Schmidt, H. (1982) Theorie und Technik der Nachrichtenkabel, Dr. Alfred Hüthing, Verlag, Heidelberg.
10. Stadler, E. (1973) Hochfrequenztechnik, Vogel – Vergal.
11. Uzgören, F. (1982) İki İletkenli Transmisyon Hatları, İ.T.Ü.
12. Vieth, B. (1981) Berechnungsunterlage für PE - isolierte Kabel, Siemens, NKEKB 11, Berlin.
13. Yılmaz, G. (1990) Haberleşme Kablolarında Kullanılan Petrojel Dolgu Malzemelerinin Elektriksel Parametrelerinin
Ölçümü ve Değerlendirilmesi, Türk Siemens (TSS Araştırma Sonuçları)
14. Yılmaz, G. (1994) Şehiriçi Haberleşme Kablolarının YF Parametrelerinin İncelenmesi ve 2 Mbit/s’de Kullanılabilirliğinin
Araştırılması, İTÜ Doktora Tezi.