A Comparison Between Ammonia-Water and Water-Lithium Bromide Solutions in Absorption Heat Transformers
Journal Name:
- Uludağ Üniversitesi Mühendislik-Mimarlık Fakültesi Dergisi
Key Words:
Keywords (Original Language):
Author Name | University of Author | Faculty of Author |
---|---|---|
Abstract (2. Language):
This study included an investigation to analyze the Absorption Heat Pump (AHP) and Absorption Heat
Transformer (AHT) using ammonia-water and water-lithium bromide solutions. A fundamental AHP and AHT systems
are described and the operating sequence is explained. Since the AHT systems widely use ammonia-water solution with
ammonia as the refrigerant and water-lithium bromide solution with water as the refrigerant, the comparison of the two
is presented in respect of the coefficient of performance (COP), the flow ratio (FR) and the maximum system pressure.
It is concluded that the AHT system using water-lithium bromide solution provided better performance than the system
using ammonia-water solution.
Bookmark/Search this post with
Abstract (Original Language):
Bu çalışma, amonyak-su ve lityum bromür-su eriyiği kullanan Soğurmalı Isı Pompası (AIP) ve Soğurmalı Isı
Yükseltici (AIY) sistemlerin analizi üzerine bir çalışmayı içermektedir. Temel AIP ve AIY sistemleri izah edilmiş ve
çalışma prensipleri açıklanmıştır. AIY sistemleri, genellikle soğutucu akışkan olarak amonyağın kullanıldığı amonyaksu
eriyiği ve soğutucu akışkan olarak suyun kullanıldığı lityum bromür-su eriyiklerini yaygın olarak kullandıklarından,
bu iki çift ısıtma tesir katsayısı, dolaşım oranı ve maksimum sistem basınçları dikkate alınarak karşılaştırılmıştır. Yapılan
analiz sonucunda, lityum bromür-su eriyiği kullanan AIY sistemin, amonyak-su eriyiği kullanan sisteme göre daha
iyi bir performans gösterdiği sonucuna varılmıştır.