Implant-supported prosthetic restorations have found a wide range of use for the restoration of a single missing tooth to edentulous cases as well recently, implant usage is nn expensive and long-term treatment composed of surgical and prophetic phases. Appropriate biomechanical approaches have great role in success of implant-supporLed prosthetic restorations. Biomechanics in dental implants consist of various factors as the form oi die impiant, diameter, length, structure of the adjacent bone, design of" the superstructure and the material used. With various stress analyses, the force loaded to the implant and adjacent bone structure und the effects of these forces are investigated. Successful results have been obtained in this field by the use of three-dimensional finite element method for stress analyses. The altitude of natural teeth and dental implants against the forces delivered are different Irom each otherdn the same way, the distribution of forces upon the cortical and spongioid bone struelure differs as well. The design and the material used in superstructure cause differences in force di s tri bution. I n thi s arti cle, bioincchaiiical principles in implant-supported prosthetic restorations and appropriate approaches in treatment based upon these principles are discussed.
Abstract (Original Language): 
Implant destekli protetik restorasyonlar, günümüz diş hekimliğinde tek diş eksikliğinden, tam dişsizlik vakalarına kadar oldukça geniş bir uygulama ulam bulmuştur. Implant uygulamaları, cerrahi ve protetik fazı içeren pahalı ve uzun süreli tedavilerdir. Impiant destekli protetik restorasyonların babamında, uygun biyomekanik yaklaşımın hiiviiV rnlıi vurHır Hr-ni-al ittin! nni-lnı-rU :plaııtın şekli, çapı, u/unluğu, çevre kemik dokusunun yapısı, protetik üst yapı dizaynı ve kullanılan materyal gibi pek çok konumu içerir. Çeşitli stres analizleriyle:, implanta ve çevre kemik dokuya iletilen kuvvetler ve bu kuvvetlerin etkisi araştırılmaktadır. Üç boyutlu sonlu elemanlar stres analiz yöntemi ile bu alanda oldukça başarılı sonuçlar elde edilmekLcdir. Doğal dişlerin ve dental implantlarm gelen kuvvetler karşısındaki davranışları birbirinden farklıdır. Aynı şekilde, kortikal ve spongioz kemikteki kuvvet dağılımları farklılık göstermekledir. Protetik üst yapılarda kullanılan materyaller ve üst yapının dizaynı, kuvvet iletiminde değişikliklere yol açmaktadır. Bu makalede, implant destekli protetik restorasyonlarda biyomekanik İlkeler ve bu ilkeler ışığında uygun tedavi yaklaşımları hakkında bilgi verilmiştir.
90-95

REFERENCES

References: 

1- Akça K. Mandibtılcr Kennedy I ve II Vakalarında Uygulanan Implant Destekli Sabit İpoteklerde Kemiğin Farklı Bukko-Lingııal Açılanmasından Kaynaklanan Streslerin Üç Boyutlu Sonlu Elemanlar Stres Analiz Yöntemi İle Araştırılması. Doktora Tezi. Hacettepe Üniversitesi Sağlık Bilimleri Enstitüsü, Ankara, 1998.
2- BaiaiHMite T. et al.
Th
e Experimental Verification of the Efficacy of Finite Element Modeling to Dental Implant Svslems. Journal of Oral Implantology 1 996: 22 (2): 104-110.
3- Bcnzing UR, Gall H, Weber H. Riomeclianieal Aspects of Two Different Implant-Prosthetic Concepts for Edentulous Maxillae. Jnt J Oral Maxtllofac Implants 1995: 10(2): 188-198.
4- Çİftçt Y- İmplant ÜV-cri SabiL Protetik Restorasyonlarda Kullanılan Farklı Kaplama Materyallerinin, Stres Dağılımına Etkisi. Doktora Tezi. Hacettepe Üniversitesi Sağlık Bilimleri Enstitüsü, Ankara, !998.
5- Engelman MJ.
Clinica
l Decision Making and Treatment Planning in Osseointegratton. Quintessence Publishing Co. Inc Chicago. ! 996: 81-161,.
6- Melo C, Matsushita Y, Koyeno K, Hirowatnri H, Suetsugo T. Comparative Stress Analyses os Fixed Free-end Osseoinlegrated Prostheses Using the Finite Element Method. Journal of Oral Implantology 1995: 21 (4): 290-294.
7- OsIcr JF. Biomechanics! [joad Analysis of Canlilevered Implant Systems. Journal of Oral Implantology 1991: 17(1): 40-47.
8- Parel SM. Prosthesis Design and I'realment Planning for the Partiallv Edentulous Implant Patient. Journal of"Oral Implantology 1996: 12(1): 31-33.
9- Rangeit DR., Sullivan RM-, Jcmt TM. Load Factor Control for Implants in the Posterior Partially Edentulous Segment. Int J Oral Maxillofac Implants 1997: 12(3): 360- 370.
10-Uysal M. el al. Kflîcacy of the İnEramobile connector in implant Tooth-Supported Fixed Prostheses: An Experimental Stress Analysis. Int J Prosthodont. 1996: 9(4): 355-361.
Jl-Watzck G- Elldossmus Tmplants: Scientific and Clinical Aspects. Quintessence Publishing Co, Inc Chicago, 1996: 291-315.
32-Weinberg LA. The Biomechanics of Force Distribution İn Tmplant-Suppnrted Prostheses. Int J Oral Maxillofae Implants 1993:8(1): 19-31.