Abstract (2. Language): 
We aimed in this study to determine our normal values of pattern visual evoked potential test. Pattern visual evoked potential test was administered to healthy and 8 to 59-year-old subjects who have full visual acuities in the Electrophysiology Laboratory at the Ophthalmology Department of Gulhane Military Medical Academy. Results were evaluated on the basis of three age groups (8 to 19, 20 to 39 and 40 to 59). Pattern visual evoked potential recordings were obtained by using five different check sizes in order to objectively determine the different levels of visual acuity. All the recordings were made using the recommended standards of International Society for Clinical Electrophysiology of Vision (ISCEV). An emphasis was made that every laboratory should have its normal values in its own laboratory environment.
Abstract (Original Language): 
Çalışmamızda desen görsel uyarılmış yanıt testi değerlendirmelerimiz için normal değerlerin ortaya konması amaçlanmıştır. Gülhane Askeri Tıp Akademisi Göz Hastalıkları Anabilim Dalı Oküler Elektrofizyoloji Laboratuvarında, sağlıklı ve görme keskinliği tam olan, 8 ile 59 yaş aralığındaki hastalara desen görsel uyarılmış yanıt testi uygulanmıştır. Sonuçlar üç yaş grubu halinde (8-19; 20-39; 40-59) değerlendirilmiştir. PVER testi ile değişik düzeylerdeki görme keskinliklerini objektif olarak öngörebilmek üzere beş farklı desende kayıtlar alınmıştır. Tüm kayıtlar, Uluslararası Elektrofizyoloji Cemiyeti'nin (ISCEV) tavsiye ettiği standartlar kullanılarak yapılmıştır. Sonuç olarak, her elektrofizyoloji laboratuvarının kendi normal değerlerini kendi özgün ortamında belirlemesi gerekliliği vurgulanmıştır.
247-250

REFERENCES

References: 

1. Ýlker SS, Sobacý G, Yýldýrým E. Flaþ ERG,
desen ERG, EOG, flaþ VER, desen VER,
desen onset-offset VER'in toplumumuzdaki normal deðerleri. Türk Oftalmoloji
Gazetesi 1992; 22: 193-195.
2. Nakamura A, Akio T, Matsuda E, Wakami
Y. Pattern visual evoked potentials in
malingering. J Neuroophthalmol 2001; 21:
42-45.
3. Hashiba A, Tabuchi A, Matsuda E,
Yamaguchi W. Visual acuity measured by
pattern visual evoked potential. Nippon
Ganka Gakkai Zasshi. 1997; 101: 644-647.
4. Odom JV, Bach M, Barber C, et al. Visual
evoked potentials standard (2004). Doc
Ophthalmol 2004; 108: 115-123.
5. Brigell M, Bach M, Barber C, Kawasaki K,
Kooijman A. Guidelines for calibration of
stimulus and recording parameters used in
clinical electrophysiology of vision.
Calibration Standard Committee of the
International Society for Clinical Electrophysiology of Vision (ISCEV). Doc Ophthalmol 1998; 95: 1-14.
6. Brigell MG. The visual evoked potential.
In: Fishman GA, Birch DG, Holder GE,
Brigell MG (eds). Electrophysiologic
Testing in Disorders of the Retina, Optic
Nevre and Visual Pathway. 2nd ed. San
Fransisco: The Foundation of the American Academy of Ophthalmology, 2001:
237-279.
7. Oken BS, Chiappa KH, Gill E. Normal
temporal variability of the P100. Electroencephalogr Clin Neurophysiol 1987; 68:
153-156.
8. Sokol S, Hansen VC, Moskowitz A,
Greenfield P, Towle VL. Evoked potential
and preferential looking estimates of visual
acuity in pediatric patients. Ophthalmology
1983; 90: 552-562.
9. Sokol S, Moskowitz A, Towle VL. Agerelated changes in the latency of the visual
evoked potential: influence of check size.
Electroencephalogr Clin Neurophysiol
1981; 51: 559-562.
10. Seiple WH, Kupersmith MJ, Nelson JI,
Carr RE. The assessment of evoked potential contrast thresholds using real-time
retrieval. Invest Ophthalmol Vis Sci 1984;
25: 627-631.
11. Akhan G, Çalýþkan S, Karaca H. Saðlýklý
kiþilerde cinsiyetler arasýnda görsel uyarýlmýþ potansiyellerin karþýlaþtýrýlmasý. Ýnönü
Üniversitesi Týp Fakültesi Dergisi 1995; 2:
169-171.
12. Wright KW, Eriksen KJ, Shors TJ, Ary JP.
Recording pattern visual evoked potentials
under chloral hydrate sedation. Arch
Ophthalmol 1986; 104: 718-721.

Thank you for copying data from http://www.arastirmax.com