EXPERIMENTALLY INVESTIGATION OF THE EFFECT OF A SQUARE CROSS-SECTIONAL OBSTACLE LOCATED IN A CHANNEL ON HEAT TRANSFER
Journal Name:
- Sigma Mühendislik ve Fen Bilimleri Dergisi
Key Words:
Keywords (Original Language):
Author Name | University of Author | Faculty of Author |
---|---|---|
Abstract (2. Language):
In the present study, the effects of a square cross-sectional obstacle, located before the heated zone of a
rectangular channel normal to the flow direction and parallel to the heated surface, on heat transfer and
friction characteristics are investigated, experimentally. The experiments were conducted for Re number in
the range of 3.103
<Re<15.103
. It was seen that, the size and location of the obstacle, which can be changed
vertically and horizontally, affect heat transfer. Optimum parameters that cause maximum heat transfer
enhancement were determined. 142 % heat transfer enhancement was obtained with the obstacle for optimum
conditions while increase in friction factor was 200 %.
Bookmark/Search this post with
Abstract (Original Language):
Bu çalışmada, dikdörtgen kesitli bir kanalın içerisinde –ısıtma bölgesi önüne- akışa dik ve kanal tabanına
paralel olarak yerleştirilen kare kesitli bir engelin ısı transferi ve sürtünme kayıp karakteristikleri üzerindeki
etkileri deneysel olarak incelenmiştir. Reynolds sayısının 3.103
<Re<15.103 aralığında incelendiği çalışmada,
yatay ve düşey doğrultuda konumu değiştirilen engelin konumunun ve boyutlarının ısı transferi üzerinde etkili
olduğu ve maksimum ısı transferinin elde edildiği optimum parametreler tespit edilmiştir. Kanal içerisine
yerleştirilen engelin-optimum konum ve boyutta- ısı transferinde %142 gibi bir iyileşme sağladığı ancak,
sürtünme kayıplarında %200 oranında bir artışın olduğu belirlenmiştir.
FULL TEXT (PDF):
- 3
65-73