Comparing the Primary Stability of Three Different Orthodontic Mini-Implants with Various Dimensions on Artificial Bone

Journal Name:

Publication Year:

Abstract (2. Language): 
Background/Purpose: The Development of mini-implant as a mean of maximum anchorage achieved outspread scope for enhancing better orthodontic outcomes, and their success is highly influenced by their primary stability. The aims of this study were the evaluation and comparison the primary stability of three various companies with different shapes and dimensions and to evaluate the effect of the dimensions of the miniscrew on the primary stability. Methods: The study sample of this study consisted of sixty orthodontic mini-implants (self-drilling) from three various manufactures (KJ Meditech, Hubit, and Dentos), each sort of these mini-implants was presented in two different lengths, 8 mm and 10 mm, and two different diameters, 1.4 mm and 1.6 mm. All the orthodontic mini-implants were inserted into simulated artificial bone of anterior region of the maxilla manually. Insertion torque (IT), and the pullout strength values were recorded and compared using ANOVA and Tukey honestly significant difference tests. Results: The results showed that the mean values of the pullout strength of KJ Meditech mini-implants were greater than those of Hubit and Dentos mini-implants respectively, and there was highly significant difference among these various manufactures. Furthermore, the mean values of pull out test were higher for mini-implants with dimensions 1.6 mm × 10 mm, and then followed by 1.6 mm × 8 mm, 1.4 mm × 10 mm, and 1.4 mm × 8 mm. Conclusion: The primary stability was greater in KJ Meditech mini-implants than Hubit and Dentos mini-implants respectively. Moreover, the length and the diameter had direct relation with the primary stability, and the diameter achieved higher effect on the primary stability than the length.
128
134

REFERENCES

References: 

[1] Papadopoulos, Moschos A., ed. Orthodontic treatment of the Class II noncompliant patient: Current principles
and techniques. Elsevier Health Sciences, 2006.
[2] Roberts-Harry, D., and J. Sandy. “Orthodontics. Part 9: Anchorage control and distal movement.” British Dental
Journal, Vol. 196, No. 5, 2004, pp. 255-63.
[3] Bumann, A., K. Wiemer, and J. Mah. “Tomas-eine praxisgerechte Lösung zur temporären kieferorthopädischen
Verankerung.” Kieferorthop, Vol. 20, No. 3, 2006, pp. 223-32.
[4] Papadopoulos, Moschos A., and Fadi Tarawneh. “The use of miniscrew implants for temporary skeletal anchorage
in orthodontics: A comprehensive review.” Oral Surgery, Oral Medicine, Oral Pathology, Oral Radiology, and
Endodontology, Vol. 103, No. 5, 2007, pp. e6-e15.
[5] Nienkemper, Manuel, et al. “Measurement of mini-implant stability using resonance frequency analysis.” The
Angle Orthodontist, Vol. 83, No. 2, 2012, pp. 230-38.
[6] Son, Seil, et al. “Comparative study of the primary stability of self-drilling and self-tapping orthodontic
miniscrews.” American Journal of Orthodontics and Dentofacial Orthopedics, Vol. 145, No. 4, 2014, pp. 480-85.
[7] Hung, Emily, et al. “Effects of pilot hole size and bone density on miniscrew implants’ stability.” Clinical Implant
Dentistry and Related Research, Vol. 14, No. 3, 2012, pp. 454-60.
[8] Kim, Jung Suk, et al. “Comparison of success rates of orthodontic mini-screws by the insertion method.” The
Korean Journal of Orthodontics, Vol. 42, No. 5, 2012, pp. 242-48.
[9] Cousley, Richard. “Mini-implants in orthodontics. Innovative anchorage concepts (2008).” 2009, pp. 215-16.
[10] Kim, Jong-Wan, Sug-Joon Ahn, and Young-Il Chang. “Histomorphometric and mechanical analyses of the drillfree
screw as orthodontic anchorage.” American Journal of Orthodontics and Dentofacial Orthopedics, Vol. 128,
No. 2, 2005, pp. 190-94.
[11] Friberg, B., et al. “Evaluation of bone density using cutting resistance measurements and microradiography. An
in vitro study in pig ribs.” Clinical Oral Implants Research, Vol. 6, No. 3, 1995, pp. 164-71.
Mohammed, et al. Int J Med Res Health Sci 2018, 7(1): 128-134
133
[12] Kido, Hirofumi, et al. “Implant diameter and bone density: Effect on initial stability and pull-out resistance.” The
Journal of Oral Implantology, Vol. 23, No. 4, 1997, pp. 163-69.
[13] Cheng, Shih-Jung, et al. “A prospective study of the risk factors associated with failure of mini-implants used for
orthodontic anchorage.” International Journal of Oral & Maxillofacial Implants, Vol. 19, No. 1, 2004.
[14] Huja, S.S., et al. “Biomechanical and histomorphometric analyses of monocortical screws at placement and 6
weeks postinsertion.” Journal of Oral Implantology, Vol. 32, No. 3, 2006, pp. 110-16.
[15] Sakoh, Jun, et al. “Primary stability of a conical implant and a hybrid, cylindric screw-type implant in
vitro.” International Journal of Oral & Maxillofacial Implants, Vol. 21, No. 4, 2006.
[16] Tseng, Yu-Chuan, et al. “Effect of anchor length on the pullout strength of palatal mini implants.” Implant
Dentistry, Vol. 26, No. 4, 2017, pp. 553-58.
[17] Lim, Seon-A., Jung-Yul Cha, and Chung-Ju Hwang. “Insertion torque of orthodontic miniscrews according to
changes in shape, diameter and length.” The Angle Orthodontist, Vol. 78, No. 2, 2008, pp. 234-40.
[18] Holm, Lindsy, et al. “An in vitro study of factors affecting the primary stability of orthodontic mini-implants.” The
Angle Orthodontist, Vol. 82, No. 6, 2012, pp. 1022-28.
[19] Hosein, Yara K., et al. “A comparison of the mechanical measures used for assessing orthodontic mini-implant
stability.” Implant Dentistry, Vol. 26, No. 2, 2017, pp. 225-31.
[20] Devlin, H., K. Horner, and D. Ledgerton. “A comparison of maxillary and mandibular bone mineral densities.” The
Journal of Prosthetic Dentistry, Vol. 79, No. 3, 1998, pp. 323-27.
[21] Misch, Carl E. Contemporary Implant Dentistry-E-Book. Elsevier Health Sciences, 2007.
[22] Miyajima, Kuniaki, et al. “Three-dimensional finite element models and animal studies of the use of mini-screws
for orthodontic anchorage.” Craniofacial Growth Series, Vol. 42, 2005, p. 269.
[23] Tabassum, Afsheen, et al. “Influence of surgical technique and surface roughness on the primary stability
of an implant in artificial bone with different cortical thickness: A laboratory study.” Clinical Oral Implants
Research, Vol. 21, No. 2, 2010, pp. 213-20.
[24] Mattos, Cláudia Trindade, Antônio Carlos de Oliveira Ruellas, and Carlos Nelson Elias. “Is it possible to re-use
mini-implants for orthodontic anchorage? Results of an in vitro study.” Materials Research, Vol. 13, No. 4, 2010,
pp. 521-25.
[25] Pithon, Matheus Melo, Daniel Santos Fonseca Figueiredo, and Dauro Douglas Oliveira. “Mechanical evaluation
of orthodontic mini-implants of different lengths.” Journal of Oral and Maxillofacial Surgery, Vol. 71, No. 3,
2013, pp. 479-86.
[26] Marquezan, Mariana, et al. “Does cortical thickness influence the primary stability of miniscrews? A systematic
review and meta-analysis.” The Angle Orthodontist, Vol. 84, No. 6, 2014, pp. 1093-1103.
[27] Florvaag, Britta, et al. “Biomechanical properties of orthodontic miniscrews. An in-vitro study.” Journal of
Orofacial Orthopedics/Fortschritte der Kieferorthopädie, Vol. 71, No. 1, 2010, pp. 53-67.
[28] Nienkemper, Manuel, et al. “Orthodontic mini-implant stability at different insertion depths.” Journal of
Orofacial Orthopedics/Fortschritte der Kieferorthopädie, Vol. 77, No. 4, 2016, pp. 296-303.
[29] Pithon, Matheus Melo, Matilde Gonçalves Nojima, and Lincoln Issamu Nojima. “Primary stability of orthodontic
mini-implants inserted into maxilla and mandible of swine.” Oral surgery, Oral Medicine, Oral Pathology and
Oral Radiology, Vol. 113, No. 6, 2012, pp. 748-54.
[30] Migliorati, Marco, et al. “Orthodontic miniscrews: An experimental campaign on primary stability and bone
properties.” European Journal of Orthodontics, Vol. 37, No. 5, 2014, pp. 531-38.
[31] Oliscovicz, Nathalia Ferraz, et al. “Analysis of primary stability of dental implants inserted in different substrates
using the pullout test and insertion torque.” International Journal of Dentistry, Vol. 2013, 2013.
[32] Lee, Jong Suk. Applications of Orthodontic Mini Implants. Quintessence Publishing Company, 2007.
[33] Roberts, W. E. “Bone dynamics of osseointegration, ankylosis, and tooth movement.” Journal (Indiana Dental
Association), Vol. 78, No. 3, 1999, pp. 24-32.
Mohammed, et al. Int J Med Res Health Sci 2018, 7(1): 128-134
134
[34] Cha, Jung-Yul, et al. “Miniscrew stability evaluated with computerized tomography scanning.” American
Journal of Orthodontics and Dentofacial Orthopedics, Vol. 137, No. 1, 2010, pp. 73-79.
[35] Huja, Sarandeep S., et al. “Pull-out strength of monocortical screws placed in the maxillae and mandibles of
dogs.” American Journal of Orthodontics and Dentofacial Orthopedics, Vol. 127, No. 3, 2005, pp. 307-13.
[36] Ono, A., M. Motoyoshi, and N. Shimizu. “Cortical bone thickness in the buccal posterior region for orthodontic
mini-implants.” International Journal of Oral and Maxillofacial Surgery, Vol. 37, No. 4, 2008, pp. 334-40.
[37] Momin, M.A., T. Kurabayashi, and T. Yosue. “Quantitative and morphological evaluation of cancellous and
cortical bone of the mandible by CT.” OMICS Journal of Radiology, Vol. 3, No. 155, 2013, p. 2.
[38] Laursen, Morten G., Birte Melsen, and Paolo M. Cattaneo. “An evaluation of insertion sites for mini-implants: a
micro-CT study of human autopsy material.” The Angle Orthodontist, Vol. 83, No. 2, 2012, pp. 222-29.
[39] Chang, Jenny Zwei-Chieng, et al. “Effects of thread depth, taper shape, and taper length on the mechanical
properties of mini-implants.” American Journal of Orthodontics and Dentofacial Orthopedics, Vol. 141, No. 3,
2012, pp. 279-88.
[40] Shah, Ankit H., et al. “Effects of screw and host factors on insertion torque and pullout strength.” The Angle
Orthodontist, Vol. 82, No. 4, 2011, pp. 603-10.
[41] Hitchon, Patrick W., et al. “Factors affecting the pullout strength of self-drilling and self-tapping anterior cervical
screws.” Spine, Vol. 28, No. 1, 2003, pp. 9-13.
[42] Park, Hyo-Sang, Seong-Hwa Jeong, and Oh-Won Kwon. “Factors affecting the clinical success of screw implants
used as orthodontic anchorage.” American Journal of Orthodontics and Dentofacial Orthopedics, Vol. 130, No.
1, 2006, pp. 18-25.
[43] Wu, Tzu-Ying, Shou-Hsin Kuang, and Cheng-Hsien Wu. “Factors associated with the stability of mini-implants
for orthodontic anchorage: A study of 414 samples in Taiwan.” Journal of Oral and Maxillofacial Surgery, Vol.
67, No. 8, 2009, pp. 1595-99.
[44] Holmgren, Eric P., et al. “Evaluating parameters of osseointegrated dental implants using finite element
analysis-a two-dimensional comparative study examining the effects of implant diameter, implant shape, and
load direction.” Journal of Oral Implantology, Vol. 24, No. 2, 1998, pp. 80-88.
[45] Miyawaki, Shouichi, et al. “Factors associated with the stability of titanium screws placed in the posterior region
for orthodontic anchorage.” American Journal of Orthodontics and Dentofacial Orthopedics, Vol. 124, No. 4,
2003, pp. 373-78.
[46] Walter, André, et al. “Design characteristics, primary stability and risk of fracture of orthodontic mini-implants:
Pilot scan electron microscope and mechanical studies.” Medicina Oral, Patologia Oral Y Cirugia Bucal, Vol.
18, No. 5, 2013, p. e804.
[47] Tseng, Yu-Chuan, et al. “Evaluation of mechanical strengths of three types of mini-implants in artificial
bones.” The Kaohsiung Journal of Medical Sciences, Vol. 33, No. 2, 2017, pp. 96-101.
[48] Kuroda, Shingo, et al. “Clinical use of miniscrew implants as orthodontic anchorage: success rates and
postoperative discomfort.” American Journal of Orthodontics and Dentofacial Orthopedics, Vol. 131, No. 1,
2007, pp. 9-15.
[49] Hong, Christine, et al. “Stability comparison between commercially available mini-implants and a novel design:
part 1.” The Angle orthodontist, Vol. 81, No. 4, 2011, pp. 692-99.
[50] Yu, Jian-Hong, et al. “Mechanical effects of micro-thread orthodontic mini-screw design on artificial cortical
bone.” Journal of Medical and Biological Engineering, Vol. 34, No. 1, 2014, pp. 49-55.
[51] Wang, Chau-Hsiang, et al. “Mechanical strength of orthodontic infrazygomatic mini-implants.” Odontology, Vol.
99, No. 1, 2011, pp. 98-100.
[52] Assunção, Viviane A., et al. “Insertion torque and pull-out strength of orthodontic mini-implants comparing
manual and motor insertion methods.” Journal of Craniofacial Surgery, Vol. 26, No. 3, 2015, pp. 993-96.

Thank you for copying data from http://www.arastirmax.com