In this article we reviewed the role of end-tidal CO2 monitoring the critical care setting as a reliable predictor of tracheal intubation and outcome of patients in emergency setting. End-tidal CO2 concentration level is reported to serve as a discriminating factor between survivors and non-survivors in case of cardiopulmonary collapse. Patients with certain levels of end-tidal CO2 concentration had significantly lower rates of survival and return of spontaneous circulation. Published data also suggest that initial ETC2 concentration level can be an important predictor of successful endotracheal intubation in life-saving procedures. More prevalent utilization of capnograph will be a useful adjunct in both detecting endotracheal intubation and also guiding bedside monitoring of cardiopulmonary resuscitation.
Abstract (Original Language): 
Bu çalışmada end-tidal karbon dioksit monitörizasyonunun kritik bakım koşullarındaki yerini, kullanımını ve acil koşullarda trakeal entübasyonu ve klinik gidişi öngörmedeki güvenirliliği gözden geçirilmiştir. Kardiyopulmoner kollaps koşullannda end-tidal karbon dioksit konsantrasyonu düzeyinin sağkalan ve kaybedilen olguların ayırt edilmesinde rol oynayabileceğini gösteren literatür bilgileri bulunmaktadır. Belirli end-tital karbondioksit konsantrasyonu düzeylerinin sağkalımı ve spontan dolaşımın geri dönüşünü öngörebileceği bildirilmiştir. Bununla birlikte birçok yayında da endotrakeal entübasyondan sonra ölçülen ilk end-tidal karbondioksit düzeyinin acil koşullarda doğru ve yanlış entübasyonu birbirinden ayırabildiği gösterilmiştir. Kapnografinin kritik bakım koşullarında daha yaygın kullanımı, endotrakeal entübasyonunun doğrulanmasında ve kardiyopulmoner resusitasyonun yatakbaşı izleminde yardımcı olacaktır.
207-213

REFERENCES

References: 

1. Anton WR, Gordon RW, Jordan TM et al. A disposable end-tidal CO2 detector to verify endotracheal intubation. Ann Emerg Med 1991; 20: 271-275.
2. Sanders AB. Capnometry in emergency medicine. Ann Emerg Med 1989; 18: 1287-1290.
3. Sayah AJ, Peacock WF, Overton DT. End-tidal CO2 measurement in the detection of esophageal intubation during cardiac arrest: Ann Emerg Med 1990; 19: 857-860.
4. American College of Emergency Physicians. Expired carbon dioxide monitoring. Ann Emerg Med 1995; 25: 441.
5. DeBehnke DJ, Swart GL. Cardiac Arrest. Emerg Med Clin North Am 1996; 14: 57-83.
6. Miller RD. Anesthesia: 4th ed: New York; Churchill Livingstone, 1994; 1267-1274.
7. Morgan GE, Mikhail MS. Clinical Anesthesiology. 1st ed. Appleton & Lange, 1992; 90-92.
8. A Comprehensive Study Guide. 2nd ed. FACEP, McGraw-Hill, 1992; 10-12.
9. Sanders AB, Atlas M. Expired CO2 as an index of coronary perfusion pressure: Am J Emerg Med 1985; 3: 147.
10. Sanders AB, Ewy GA, Bragg S, et al. Expired FCO2 as a prognostic indicator of successful resuscitation from cardiac arrest. Ann Emerg Med 1985; 14: 948-952.
11. Weil MH, Bisera J, Trevino RR et al. Cardiac output and end-tidal carbon dioxide. Crit Care Med 1985; 13: 907.
12. Sanders AB, Kern KB, Otto CW et al. End-tidal carbon dioxide monitoring during cardiopulmonary resuscitation. A prognostic indicator for survival. JAMA 1989; 262: 1347-1351.
13. Anderson DE, Dhokalia A, Parsons DJ et al: High end tidal CO2 association with blood pressure response to sodium loading in older adults. J Hypertens 1996; 14: 1073-1079.
14. Lenz G, Heipertz W, Epple E. Capnometry for continuous postoperative monitoring of nonintubated, spontaneously breathing patients. J Clin Monit 1991; 7: 245-248.
15. Kalenda Z. The capnogram as a guide to the efficacy of cardiac massage. Resuscitation 1978; 6: 259-263.
16. Barton CW, Wang ES. Correlation of end-tidal CO2 measurements to arterial PaC2 in nonintubated patients. Ann Emerg Med 1994; 23: 560-563.
17. Trillö G, von Planta M, Kette F. ETCO2 monitoring during low flow states: clinical aims and limits. Resuscitation 1994; 27: 1-8.
18. Gudipat CV, Weil MH, Bisera J, et al. Expired carbon dioxide: A noninvasive monitor of cardiopulmonary resuscitation. Circulation 1988; 77: 234.
19. Wayne MA, Levine RL, Miller CC. Use of end-tidal carbon dioxide to predict outcome in prehospital cardiac arrest. Ann Emerg Med 1995; 25: 762-767.
20. O'Flaherty. Capnography: principles and practice. 1st ed. London. BMJ Publishing Group, 1994; 83-87.
21. Samallhout B, Kalenda Z. An atlas of capnography. 1st ed. Amsterdam. Kerchebosch-Zeist, 1981; 122-127.
22. Domsky M, Wilson RF, Heins J. Intraoperative end-tidal carbon dioxide values and derived calculations correlated with outcome: prognosis and capnograhy. Crit Care Med 1995; 23: 1497-1503.
23. Hoffman RA, Krieger BP, Kramer MR, et al. End-tidal carbon dioxide in critically ill patients during changes in mechanical ventilation. Am Rev Respir Dis 1989; 140: 1265-1268.
24. Reid CW, Martineau RJ, Miller DR et al. A comparison of transcutanecus end-tidal and arterial measurements of carbon dioxide during general anaesthesia. Can J Anaesth 1992; 39: 31-36.
25. Santos LJ, Varon J, Pic-Aluas L et al. Practical uses of end-tidal carbon dioxide monitoring in the emergency department. J Emerg Med 1994; 12: 633-644.
26. Sum Ping ST, Mehta MP, Symreng T. Accuracy of the FEF CO2 detector in the assessment of endotracheal tube placement. Anesth Analg 1992; 74: 415-419.
27. Thrush DN, Mentis SW, Downs JB. Weaning with end-tidal CO2 and pulse oximetry. J Clin Anesth 1991; 3: 456-460.
28. Wilson RF, Tyburski JG, Kubinec SM. Intraoperative end-tidal carbon dioxide levels and derived calculations correlated with outcome in trauma patients. J Trauma 1996; 41: 606-611.
29. Kayhan (Esener) Z. İzlem, Ölçüm ve Kayıt Yöntemleri. Klinik Anestezi, 2. Baskı, Ankara. Logos Yayıncılık. 1997; 41-43.
30. Gravenstein JS, Paulus DA, Hayes TJ. Capnography in clinical practice. 1st ed. Boston. Butterworths. 1989; 126-130.
31. Garnett AR, Ornato JP, Gorizalez ER, et al. End-tidal carbon dioxide monitoring during cardiopulmonary resuscitation. JAMA 1987; 257: 512-515.
32. Falk JL, Rackow EC, Weil MH. End-tidal carbon dioxide concentration during cardiopulmonary resuscitation: N Engl J Med 1988; 318: 607.
33. Egleston CV, Ben Aslam H, Lambert MA. Capnography for monitoring nonintubated spontaneously breathing patients in an emergency room setting. J Acid Emerg Med 1997; 14: 222-224.
34. Wright SW. Conscious sedation in the emergezıcy department: the value of capnography and pulse oximertry. Ann Emerg Med 1992; 21: 551-555.
35. Dash HH, Bithal PK, Joshi S, et al. Airway pressure monitoring as an aid in the diagnosis of air embolism. J Neurosurg Anesthesiol 1993; 5: 159-163.
36. Kerr ME, Zempsky J, Sereika 5, et al. Relationship between arterial carbon dioxide and end-tidal carbon dioxide in mechanically ventilated adults with severe head trauma: Crit Care Med 1996; 24: 785-790.
37. Chopin C, Fesard P, Mangalaboyi J, et al. Use of capnography in diagnosis of pulmonary embolism during acute respiratory failure of chronic obstructive pulmonary disease. Crit Care Med 1990; 18: 353-357.
38. Murray AIP, Modell JH, Gallagher RJ, et al. Titration of PEEP by the arterial minus end-tidal carbon dioxide gradient. Chest 1984; 85: 100.
39. Blanch L, Fermandez R, Saura P, et al. Relationship between expired capnogram and respiratory system resistance in critically ill patients during total ventilatory support. Chest 1994; 105: 219-223.
40. Sanders KC, Clum WB, Nguyen SS, et al. End-tidal carbon dioxide detection in emergency intubation in four groups of patients. J Emerg Med 1994; 12: 771-777.
41. Hayden SR, Sciammarella J, Viccellio P, et al. Colorimetric end-tidal CO2 detector for verification of endotracheal tube placement in out-of-hospital cardiac arrest. Acad Emerg Med 1995; 2: 499-502.
42. Ko FY, Hsieh KS, Yu CK. Detection of airway CO2 partial pressure to avoid esophageal intubation. Acta Paediatr Sin 1993; 34: 91-97.
43. Ornato JP, Shipley JB, Racht EM, et al. Multicenter study of a portable, handsize, colorimetric end-tidal carbon dioxide detection device. Ann Emerg Med 1992; 21: 518-523.
44. White RD, Asplin BR. Out-of-hospital quantitative monitoring of end-tidal carbon dioxide pressure during CPR. Ann Emerg Med 1994; 23: 25-30.
45. Kern KB, Sanders AB, Voorhees WD, et al. Changes in expired end-tidal carbon dioxide during cardiopulmonary resuscitation in dogs: A prognostic guide for resuscitation efforts. J Am Coll Cardiol 1989; 13: 1184-1189.
46. Varon AJ, Morrina J, Civetta JM. Clinical utility of a colorimetric end-tidal CO2 detector in cardiopulmonary resuscitation and emergency intubation. J Clin Monit 1991; 7: 289-293.
47. Levine RL, Wayne MA, Miller CC. End-tidal carbon dioxide and outcome of out-of-hospital cardiac arrest. N Engl J Med 1997; 337: 301-306.
48. Steedman DJ, Robertson CE. Measurement of end-tidal carbon dioxide concentration during cardiopulmonary resuscitation. Arch Emerg Med 1990; 7:129-134.
49. Karcıoğlu Ö. Acil Serviste Kardiyopulmoner Resusitasyon Uygulanan Hastalarda End-Tidal CO2 Monitörizasyonunun Rolü (Uzmanlık Tezi). Dokuz Eylül Üniversitesi İlk ve Acil Yardım ABD. İzmir, 1998; 42-46.