Buradasınız

H2O-LiBr VE NH3-H2O ERİYİĞİ KULLANAN TEK KADEMELİ SOĞURMALI SOĞUTMA SİSTEMLERİNİN KARŞILAŞTIRILMASI

A COMPARISON BETWEEN H2O-LiBr AND NH3-H2O SOLUTIONS IN SINGLE STAGE ABSORPTION REFRIGERATION SYSTEM

Journal Name:

Publication Year:

Abstract (2. Language): 
In recent years, research has been devoted to improvement of the performance of NH3-H2O and H2O-LiBr absorption refrigeration systems. In this study, thermodynamic analysis of NH3-H2O and H2O-LiBr single stage absorption refrigeration systems are carried out. Detailed thermodynamic properties of solutions are presented and system performances are compared at various generator, condenser, evaporator and absorber temperatures. As a result, it is seen that performance of both systems increase with increasing heater and evaporator temperatures, but decrease with increasing condenser and absorber temperatures. It is observed that generally the performance of H2O-LiBr absorption refrigeration system is better than that of the NH3-H2O system.
Abstract (Original Language): 
Son yıllarda, NH3-H2O ve H2O-LiBr eriyiği kullanan soğurmalı soğutma sistemlerinin performansının iyileştirilmesi için çalışmalar yoğunlaşmıştır. Bu çalışmada, NH3-H2O ve H2O-LiBr eriyiği kullanan tek kademeli soğurmalı soğutma sistemlerinin termodinamik analizi yapılmıştır. Eriyiklere ait termodinamik özellikler verilerek sistemlerin performansı, farklı ısıtıcı, yoğuşturucu, buharlaştırıcı ve soğurucu sıcaklıklarında karşılaştırılmıştır. Her iki sistemin de performansı ısıtıcı ve buharlaştırıcı sıcaklıklarının artışıyla artmakta ancak yoğuşturucu ve soğurucu sıcaklıklarının artışıyla azalmaktadır. Genel olarak H2O-LiBr eriyiği kullanan sistemin performansı NH3-H2O eriyiği kullanan sisteme göre daha iyi olmaktadır.
73-87

REFERENCES

References: 

Chuang C.C., Ishida M. (1990): “Comparison of Three Types of Absorption Heat Pumps
Based on Energy Utilization Diagrams”, ASHRAE Transactions, 96 (2), pp. 275-281.
Horuz İ. (1990): “Absorpsiyonlu Soğutma Sistemlerinden Amonyak-Su Çifti İle Lityum
Bromür-Su Çiftinin Mukayesesi”, Yüksek Lisans Tezi, Bursa, 147s.
Keçeciler A., Acar İ.H., Doğan A. (2000): “Thermodynamic Analysis of The Absorption
Refrigeration System with Geothermal Energy: An Experimental Study”, Energy
Conversion and Management, Vol. 41, p.37-48.
Mostafavi M., Agnew B. (1996): “The İmpact of Ambient Temparature on Lithium Bromide-
Water Absorption Machine Performance”, Applied Thermal Engineering, Vol. 16, No. 6,
p.515-522.
Saravanan R., Maiya M. P. (1998): “Thermodynamic Comparison Of Water Based Working
Fluid Combinations For A Vapour Absorption Refrigeration System”, Applied Thermal
Engineering, Vol. 18, No. 7, p.553-568.
Seara J.F., Vazquez, M. (2001): “Study and Control Optimal the Generation Temperature in
NH3-H2O Absorption Refrigeration Systems”, Applied Thermal Engineering, Vol. 21,
p.343-357.
Seewald J.S., Blanco H.P. (1994): “A Simple Model for Calculating the Performance of a
Lithium Bromide-water Coil Absorber”, ASHRAE Transactions, p.318-328.
Sun D.W. (1998): “Comparison of the Performance of NH3-H2O, NH3-LiNO3 and NH3-
NaSCN Absorption Refrigeration Systems”, Energy Conversion, Vol.39, No.5/6, p.357-
368.