Evaluation Methods of Limiting Switching Overvoltage during Line Energization

Journal Name:

Publication Year:

Abstract (2. Language): 
The transmission line faces overvoltage problem in the case of energization. There are some methods to have acceptable level of voltage. In this paper, some of the methods to solve the problem are explained and combinations of several of them are presented. A traditional way to limiting switching overvoltage is using the circuit breakers equipped with pre-insertion resistors. It has some advantage same as good effect and disadvantage same costly and complex. One of the other methods is using the surge arrester at the lines. Description of the traditional method and the other ways are presented. At the end the comparison of these methods by using the PSCAD software shows the effect of different methods.
FULL TEXT (PDF): 
62-67

REFERENCES

References: 

[1] I. Sadeghkhani, A. Ketabi, and R. Feuillet, “Estimation of Temporary Overvoltages during Power System Restoration using Artificial Neural Network,” in Proc. 15th International Conference on Intelligent System Applications to Power Systems, Curitiba, Brazil (2009).
[2] J.A. Martinez, R. Natarjan, E. Camm, "Comparison of statistical switching results using gaussian, uniform and systematic switching
approaches," in Proc. 2000 IEEE Power Engineering Society Summer Meeting, vol. 2, pp. 884-889.
[3] IEC standard 71-1 Insulation ’’Co-ordination part1: Definition, principles and rules’’, 7th edition, (1993).
[4] International Standard IEC 60071.2, “Insulation Co-ordinations Part 2: Application Guide,” International Electrotechnical Commission (IEC), (1996).
[5] A.C. Legate, J.H. Brunke, J.J. Ray, E.J. Yasuda, Elimination of closing resistors on EHV circuit breakers, IEEE Transactions on Power Apparatus and Systems 3 (1988) 223–231.
[6] J.R. Ribeiro, M.E. McCallum, An application of metal oxide surge arresters in the elimination of need for closing resistors in EHV breakers, IEEE Transactions on Power Delivery 4 (1989) 282–291.
[7] IEEE working group switching surges. ’’Switching surges: part IV- contrel and reduction on AC transmission lines’’ IEEE Tran on power apparatus & systems. Vol pas 101. NO. 8 August 1982. pp, 2694-2702.
[8] Bikford J. P. ’’ Energisation of Transmission Lines from Inductive Sources’’, Proc, IEE, Vol 120, NO. 8, August (1973), pp 883-890.
[9] Volker Hinrichsen.’’ Metal-Oxide Surge Arresters in High-Voltage Transmission and Distribution Systems Effective and reliable devices increasing system availability and reducing maintenance costs’’, Siemens PTD, Berlin/Germany.
[10] L. Stenstrom, M. Mobedjina, Limitation of switching overvoltages by use of transmission line surge arresters, in: CIGRE, vol. 33, (1998).

Thank you for copying data from http://www.arastirmax.com