Cyclic voltammetry (CV) and square wave voltammetry (SWV) were used for characterizing and determining Vitamin C concentration in some selected beverages and fresh edible vegetables. The oxidation peak for Vitamin C occurred at 400 mV (vs Ag /AgCl) for both CV and SWV both at glassy carbon working electrode. The influence of the operational parameters for the analytical signal was investigated. The effect of pH was also studied for both methods where pH2 and pH3 were selected as working pH for CV and SWV, respectively. Calibration graphs were set that showed a linear dependence between the peak current and Vitamin C concentration within the range of 0.008 – 0.08 mM. The Vitamin C content determined ranged between 5.26 mg/100 mL juice for Lactuca sativa and 28.3 mg/100 mL for Capsicum annum juices and 7.62 mg/100ml for lettuce and 31.1 mg/100 ml for green pepper juices obtained by squeezing fruit. The effect of temperature on vitamin C content of some selected vegetables was determined to ascertain the effect of heat on the vitamin C contents of these vegetables. The amount of Vitamin C in these vegetables was degraded when the temperature was increased from 25 - 65 0C.
39
49

REFERENCES

References: 

[1] Ahmed, R.; Qureshi, S.A.; Nisa, V.U. 2005. Studies about the
determintation of ascorbic acid by differential pulse voltammetry, Jour.
Chem. Soc. Pak., 27(2) , 168-173.
[2] Azeez, L.A.; Osunsanmi, M.; Majolagbe, A.T. 2010. Assessment of
Tubers and Corms as Nutritional Sources of Vitamin C by Cyclic
Voltammetry, Int. J. Pharma. & Bio. Archives, 1(3), 321 – 325; ISSN
0976 – 3333
[3] Azeez, L. A.; Uthman, O.; Majolagbe, K.T. 2010. Statistical Evaluation
of Titrimetric Method Using N- Bromosuccinimide (Nbs) and Cyclic
Voltammetry for the Assessment of Ascorbic Acid Level in Vegetables
and Tuber Products, Int. J. of Pharm. & Bio. Archives, 1(1), 44 – 50.
[4] Behpour M.; Golestaneh, M. Electrochemical determination of ascorbic
acid at the surface of a graphite electrode modified with a multi-walled
carbon nanotubes/tetradecyltrimethylammonium bromide. J. Appl.
Electrochem. 2010, 40, 841-847.
[5] Diet Nutrition and the Prevention of Chronic Diseases.1990. Report of a
WHO Study Group; Geneva, World Health Organization, (WHO
Technical Report Series, No. 797).
[6] Dogan, B.; Ozgen, U.; Ozkan, S.A.; Coskun, M. 2006. Anodic
voltammetric behavior of ascorbic acid and its selective determination in
pharmaceutical dosage forms and some Rosa species of Turkey. J. Anal.
Chem. 61, 1113-1120.
[7] Esch, J.R.; Friend, J. R.; Kariuki, J. K. 2010. Determination of the
Vitamin C Content of Conventionally and Organically Grown Fruits by
Cyclic Voltammetry, Int. J. Electrochem. Sci. 5, 1464 – 1474;
www.electrochemsci.org
[8] Fei, J.; Wu, K.; Yi, L.; Li, J.; Bull. 2005. Low Potential Amperometric
Determination of Ascorbic Acid at a Single-Wall Carbon Nanotubes-
Dihexadecyl Hydrogen Phosphate Composite Film Modified Electrode,
Bull, Korean Chem. Soc., 26(9), 1403.
[9] Gazdik, Z.; Zitka, O.; Petrlova, J.; Adam, V.; Zehnalek, J.; Horna,
A.;Reznicek, V.; Beklova, M.; Kizek. 2008. Determination of Vitamin C
(Ascorbic Acid) Using High Performance Liquid Chromatography
Coupled with Electrochemical Detection ,Sensors R. Sens. 8, 7097-
7112; DOI: 10.3390/s8117097; ISSN 1424-8220;
http://www.mdpi.com/journal/sensors
[10] Goyal, R. N.; Dhawan. 2006. Further Investigations into the Oxidation
Chemistry of Adenosine - Effect of Applied Potential on the Products,
Formation, A. Int. J. Electrochem. Sci., 1, 304-316.
[11] Kalanur, S. S.; Seetharamappa, J.; Katrahalli, U.; Kandagal, P. B. 2008.
Electrochemical Studies of Buzepide Methiodide and their Analytical
Applications, Int. J. Electrochem. Sci., 3, 711 – 720.
[12] Levent A.; Yardim Y.; Senturk Z. 2009. Voltammetric behavior of
nicotine at pencil graphite electrode and its enhancement determination
in the presence of anionic surfactant, Electrochimica Acta, 55, 190–195.
[13] Matei, N. and Magearu, V. 2004. Determination of Vitamin C from
Some Natural Product Preserved under Different Storage Conditions, III,
65-68
[14] Nezamzadeh, A.; Amini, M.K. 2007. Faghihian, H. Square-wave
voltametric determination of ascorbic acid based on its electrocatalytic
oxidation at zeolite-modified carbon-paste electrodes. Int. J.
Electrochem. Sci., 2, 583-594.
[15] Ogunlesi, M.; Okiei W.; Azeez, L.; Obakachi V.; Osunsanmi M.;
Nkenchor G. 2010. Vitamin C Contents of Tropical Vegetables and
Foods Determined by Voltammetric and Titrimetric Methods and Their
Relevance to the Medicinal Uses of the Plants, Int. J. Electrochem. Sci.,
5, 105 – 115.
[16] Okiei, W.; Ogunlesi, M.; Azeez, L.; Obakachi, V.; Osunsanmi, M.;
Nkenchor, G. 2009. The Voltammetric and Titrimetric Determination of
Ascorbic Acid Levels in Tropical Fruit Samples, Int. J. Electrochem.
Sci., 4, 276 – 287.
[17] Parham, H.; Esfahani, B. A. 2008. Determination of Furazolidone in
Urine by Square-Wave Voltammetric Method, J. Iran. Chem. Soc., 5(3),
453-457.
[18] Peeters, K. 2006-2007. Tetrasulphonated Phthalocyanine Thin Films
Deposited on Gold Electrodes: a study using voltammetry and
synchrotron micro X-ray fluorescence, Thesis for the degree of Dr. in
Science, Chemistry, University Gent.
[19] Pisoschi, A. M.; Danet, A. F.; Kalinowski, S. 2008. Ascorbic Acid
Determination in Commercial Fruit Juice Samples by Cyclic
International Journal of Science and Engineering Investigations, Volume 3, Issue 26, March 2014 49
www.IJSEI.com Paper ISSN: 2251-8843 ID: 32614-08
Voltammetry, J. of Automated Methods and Management in Chemistry, 8, 350-460. DOI:10.1155/2008/937651; Article ID 937651. [20] Pisoschi, AM; Pop, A; Negulescu, GP; Pisoschi, A. 2011, Feb 1. Determination of ascorbic acid content of some fruit juices and wine by voltammetry performed at pt and carbon paste electrodes. Molecules, 16(2):1349-65. DOI: 10.3390/molecules16021349. [21] Polydera, A.C; St, N.G. and P.S. 2003. Comparative shelf life study and vitamin C loss kinetics in pasteurized and high pressure processed reconstituted orange juice; Journal of Food Eng., 60, 21-23.
[22] Protti, P. 2001. Introduction to Modern Voltammetric and Polarographic Analisys Techniques, 4th Ed., AMEL. [23] Raoof, J. B.; Ojani, R.; Beitollahi, H.; Hossienzadeh, R. 2006. Electrocatalytic Determination of Ascorbic Acid at the Surface of 2, 7-Bis (ferrocenyl ethyl)fluoren-9-one Modified Carbon Paste Electrode, DOI: 10.1002/elan.200503516; www.electroanalysis.wiley-vch.de; Electroana., 18(12), 1193 – 1201. [24] Raoof, J. B.; Ojani R.; Karimi-Maleh, H. 2007. Electrocatalytic Determination of Sulfite at the Surface of a New Ferrocene Derivative-Modified Carbon Paste Electrode, Int. J. Electrochem. Sci., 2, 257 – 269.
[25] Razmi, H. and Harasi, M. 2008. Voltammetric Behavior and Amperometric Determination of Ascorbic Acid at Cadmium
Pentacyanonitrosylferrate Film Modified GC Electrode, Int. J. Electrochem. Sci., 3, 82 – 95.
[26] Shimada, Y. and Ko, S. 2006. Quantitative Determination of Ascorbic Acid in Vegetables by High-Performance Liquid Chromatography; Chugokugakuen J., 5, 13-16. [27] Sun, W.; Jiao, K.; Bull. 2005. Application of Ascorbic Acid 2-Phosphate as A New Voltammetric Substrate for Alkaline Phosphate Determination in Human Serum; ISSN 1011-3924; Chem. Soc. Ethiop., 19(2), 163-173.
[28] Williams, C. 1995. Healthy eating: clarifying advice about fruit and vegetables. British Medical J., 310, 1453–1455. [29] Xavier, J. L. N.; Ortega, E.; Ferreira, J. Z.; Bernardes, A. M.; Pérez-Herranz, V. 2011. An electrochemical Study of Phenol Oxidation in Acidic Medium, Int. J. Electrochem. Sci., 6, 622 – 636. [30] Yilmaz, S.; Sadikoglu, M.; Saglikoglu, G.; Yagmur, S.; Askin, G. 2008. Determination of Ascorbic Acid in Tablet Dosage Forms and Some Fruit Juices by DPV; Int. J. Electrochem. Sci. 3, 1534 – 1542; www.electrochemsci.org [31] Zhao1, Y. ; Bai, J.; Wang, L.; Huang, P.; Wang, H.; Liying, Z. 2006. Simultaneous Electrochemical Determination of Uric Acid and Ascorbic Acid Using L-Cysteine Self-Assembled Gold Electrode; Int. J. Electrochem. Sci., 1, 363-371.

Thank you for copying data from http://www.arastirmax.com