TRİSTÖR VE TRİYAK HARMONİKLERİNİN 3 BOYUTLU GÖSTERİMİ VE TOPLAM HARMONİK BOZUNUMA EĞRİ UYDURMA

SHOWING THE THYRISTOR AND TRIAC HARMONICS IN 3D SPACE AND CURVE FITTING TO THD

Journal Name:

Publication Year:

Keywords (Original Language):

Author NameUniversity of AuthorFaculty of Author
Abstract (2. Language): 
The switching equipment, like thyristors and triacs, are widely used power electronics. Also, they have non¬linear load characteristics and produce effective harmonics. In order to compensate harmonic currents of non¬linear loads, THD value and the amplitude of harmonics produced from loads at the working conditions should be known. Also, this process is only possible with harmonic analysis. Harmonic analysis is expensive process because of demanding special equipment. In this study, by expressing harmonics, produced thyristor and triac with different load and firing angle, in 3D space, a new viewing point to show harmonic analysis was presented; with curve fitting to the THD values at the each firing angle, polynomials were obtained; by doing so, THD values will be directly found without harmonic analysis.
Abstract (Original Language): 
Tristör ve triyak gibi anahtarlama elemanları güç elektroniğinde geniş olarak kullanılmaktadır. Bu elemanlar lineer olmayan yük karakteristiğine sahip olup etkin harmonik üretirler. Lineer olmayan bir alıcıya harmonik kompanzasyonu yapmak için, çalışma şartlarında yükün üretebileceği tüm harmonik genliklerinin ve toplam harmonik bozunum (THD-Total Harmonic Deflection) (THD) değerinin bilinmesi gereklidir. Bu da ancak harmonik analizi ile mümkündür. Harmonik analizi özel düzenekler isteyen pahalı bir işlemdir. Bu çalışmada, tristör ve triyakın çeşitli yük ve tetikleme açılarında üretmiş olduğu harmonikler 3 boyutlu uzayda ifade edilip, harmonik analiz sonuçlarının görüntülenmesine yeni bir bakış açısı getirilmiştir; her bir tetikleme açısındaki THD değerlerine eğri uydurularak polinomlar elde edilmiş, bu sayede harmonik analizi yapılmaksızın THD değerlerinin direkt olarak bulunması sağlanmıştır.
415
421

REFERENCES

References: 

Anonymous, 1993. IEEE Standard 519- "IEEE Recommended Practices and Requirements for Harmonic Control in Electric Power Systems", IEEE, New York.
Arrilaga, J., Bradley, D. A. and Bodger, P. S. 1985. Power Systems Harmonics. John Wiley and Sons, Inc.
Atmaca, E. 1995. Harmoniklerin Elektrik Donanımı Üzerindeki Etkileri. 3e Dergisi, 19, 311-318.
0
0
3
3
Mühendislik Bilimleri Dergisi 2004 10 (3) 415-421
420
Journal
of Engineering Sciences 2004 1 0 (3) 415-421
Tristör ve TriyakHarmoniklerinin Üç Boyutlu Gösterimi ve Toplam HarmonikBozunuma Eğri Uydurma, A. Altıntaş
Ay, S. 1999. Alçak Gerilim Tesislerinde Harmoniklerin İncelenmesi. Kaynak Elektrik Dergisi, 129, İstanbul,
Biran, A., Breiner, M. 1995. MATLAB for Engineers. Addison-Wesley Publishing Company.
Chicharo, J., Wang, H. 1994. Power System Harmonic Signal Estimation and Retrieval for Active Power Filter Applications. IEEE Trans. on
Power, 9 (6), 580-586.
Cooley, J. W., Tukey, J. W. 1965. An Algorithm
for the Machine Computation of Complex Fourier Series. Mathematical Computations, 19, 297-301.
Howard, A. 1991. Data Acquisition Techniques Using Personal Computers. Academic Press, Inc., 184-191.
Ingle, V. K., Proakis, J. G. 2000. Digital Signal Processing Using Matlab. Bookware Companion Series, 116-172.
Rashid, M. H. 2002. Power Electronics Handbook. Academic Press, Inc., New York, 559-615, 820-829.

Thank you for copying data from http://www.arastirmax.com