Buradasınız

Foramen Ovale'nin 2. ve 3. Trimestr İnsan Fetuslannda Morfolojik ve Morfometrik Olarak İncelenmesi

Morphological And Morphometrical Investigation of Foramen Ovale in the Second and Third Trimester Human Fetuses

Journal Name:

Publication Year:

Keywords (Original Language):

Abstract (2. Language): 
In this study we aimed to investigate the morphologic and morphometric evaluation of foramen ovale during fetal period and the results were compared regarding age and sex. For this purpose, the hearts of 66 fetuses (34 Female, 32 Male) in 2 and 3rd trimester were removed from fetuses collection of anatomy department and dissected to expose interatrial septum and foramen ovale. The morphological observation of foramen ovale were recorded and photographed. The vertical and sagittal lengths (mm) of the foramen ovale were measured by the caliper. The obtained data were evaluated statistically for the developmental period according to the age and sex by linear regression and correlation analysis. The septum primum of 6.06 % offetuses were observed in close relationship with the septum secundum allowing to blood flow. In one (LSI %) fetus there was two part of the foramen ovale, one of them was in front of the septum primum and second was behind of it. In one case (1.51 %), the septum primum was in the right part of the interatrial septum. In one case (1.51 %) the septum primum was observed as having two membrane, one of them was in the right of the interatrial septum and the other was in the left. There was no statistical differences in comparison of the sex. In the statistical analysis according to trimester age, the vertical length of the foramen ovale in third trimester was found to have significantly (p<0.05) moderate correlation (r^0.46). The data obtained from the present study can be useful in better understanding of the differentiation of the foramen ovale during the developmental period, making proper comment on the images obtained from foramen ovale of the fetuses using new imaging techniques and the determination of congenital defects.
Abstract (Original Language): 
Bu çalışmada fötal hayat boyunca foramen ovale 'nin hem morfolojik hem de morfometrik olarak değerlendirilmesi ve sonuçların yaş ve cinsiyete göre karşılaştırılması amaçlandı. Bu amaçla Anatomi anabilim dalı kolleksiyonumuzda bulunan 66 (34 dişi, 32 erkek) adet 2. ve 3. trimestr fetusların kalpleri klasik diseksiyon metodu ile çıkarılarak, septum interatrial ve foramen ovale görünür hale getirildi. Foramen ovale'nin morfolojik görünümü belirlendi ve fotoğraftandı. Foramen ovale'nin vertikal ve sagittal uzunlukları (mm) kumpas yardımı ile ölçüldü. Elde edilen ölçüm verileri ile yaş ve cinsiyete göre gelişim süreci, linear regresyon ve korelasyon analiz yöntemi ile istatistiksel olarak değerlendirildi. Fetusların % 6.06 'sında septum primum 'un septum secundum üzerine kan akışına izin verecek şekilde üst üste geldiği, % 1.51 'inde septum primumda küçük delikler bulunduğu, % 1.51 'inde septum primum'un önünde ve arkasında 2 adet açıklığın varolduğu, % 1.51 'inde septum primum 'un sağ atrium tarafında yer aldığı, % 1.51 'inde septum primum 'un, septum interatriale 'nin sağında ve solunda olmak üzere iki yapraklı olduğu gözlendi. Cinsiyet karşılaştırılması yapıldığında istatistiksel olarak anlamlı farklılık tespit edilemedi. Trimestr yaşına göre yapılan istatistiksel analizde, foramen ovale vertikal uzunluğunda3. trimestrda istatistiksel açıdan anlamlı (p<0.05) orta derecede (r = 0.46) korelasyon tespit edildi. Çalışmamızdan elde ettiğimiz verilerin foramen ovale 'nin fötal gelişim sürecinde gösterdiği farklılıkların anlaşılmasına ve görüntüleme tekniklerinden elde edilen verilerin yorumlanmasına ve konjenital defektlerin belirlenmesine katkıda bulunacağı kanaatindeyiz.
45-50

REFERENCES

References: 

1-Moore KL, Persaud TVN.
The
Developing Humarı (Clinically Oriented Embryology). 5th e d. Philadelphia: WB Saunders. 1993.
2- Datgleish AE. The development of the septum primum relative to septation in the mouse heart. JMorphol 1976; 149(3):369-82.
3-McDonald SW. James Jeffray: Observations on the heart and on the precularities of the foetus. Clin Anat 1999; 12(1):35-42.
4- Hutchins GM, Moore GW, Jones JF, Miller JT. Postnatal endocardial fibroelastosis of the valve of the foramen ovale. Am J Cardiol 1981;47(l):90-4.
5-Neyzi O, Ertugrul T. Pediatri Cilt 2. Istanbul: Nobel Tıp Kitapevi, 1990. 995-6.
6- Salih M, Demirel LC, Kurtay G. Prenatal diagnosis of ostium secundum atrial septal defect by M-mode fetal echocardiography. Gynecol Obstet Invest 1998;45(1):68-W.
7-Anderson DF, Faber JJ, Morton MJ, Parks CM, Pinson CW, Thornburg KL. Flow through the foramen ovale of the fetal and new-bom lamb. J Physiol (Lond) 1985;365:29-40.
8- Zimmer LP, Dillenburg RF, Dorneltes AP, AndradeA, Zielinsky P. Prenatal restriction of the foramen ovale. Arq Bras Cardiol 1997;68(4):285-8.
9-Momma K, Ito T, Ando M. In situ morphology of the foremen ovale in the fetal and neonatal rat. PediatrRes 1992;32(6):669~72.
10- Sweeney LJ, Rosenquist GC Closed foramen ovale:a potential entrance to left atrium. Cathet Cardiovasc Diagn 1977;3(4):385-389.
11-Arger PH, Moranz J, Mennuti MT, Devenney JE. Premature closure of the foramen ovale as a cause of intrauterine fetal ascites. Rev Interam Radiol 1979;4(2):93-4.
12- Phillipos EZ, Robertson MA, Still DK. The echocardiographic assesment of the human fetal foramen ovale. J Am Soc Echocardiogr I994;7(3):257-63.
13- Chobot V, Hornberger LK, Hagen-Ansert S, Sahn DJ. Prenatal detection of restrictive foramen ovale. J Am Soc Echocardiogr 1990;3(1):15-9.
14- Coulson CC, Küller J A. Nonimmune hydrops fetalis secondary to premature closure of the foramen ovate. Am J Perinatol 1994; 11(6): 439-40.
15-Macdonald AA. Comparative anatomy of the foramen ovale in the Suina. Anat Embryol 1988; 178(1):53-7.
16-Hagen PT, Schotz DG, Edwards WD. Incidence and size of patent foramen ovale during the first 10 decades of life:an autopsy study of 965 normal hearts. Mayo Clin Proc 1984;59(1):17-20.
17-Reig J, Mirapeix R, Jornet A, Petit M. Morphologic characteristics of the fossa ovalis as an anatomic basis for transseptal catheterization. Surg Radiol Anat 1997;19(5): 279-82.
18-Kachalia P, Bowie JD, Adams DB, Carioll BA. In utero sonographic apperance of the atrial
SDÜ Tıp Fakültesi Dergisi 1999; 6 (3):45-50
49
2.
ve 3. Trimestr İnsan Fetuslannda Foramen Ovale/Salbacak, Uysal
septum primum and septum secundum. J Ultrasound Med 1991;10(8):423-6.
19- Wilson AD, Rao PS, Aeschlimann S. Normal fetal foramen flap and transatrial Doppler velocity pattern. J Am Soc Echocardiogr 1990; 3(6): 491-4.
20-Deng J, Gardener JE, Rodeck CH, Lees WR. Fetal echocardiography in three and four dimensions. Ultrasound Med Biol 1996;22(8): 979-86.
50