Buradasınız

ÇEVRE SICAKLIĞININ BİR KOMBİNE ÇEVRİM GÜÇ SANTRALİNİN PERFORMANSINA ETKİSİ

Effect of the Ambient Temperature on the Performance of a Combined Cycle Power Plant

Journal Name:

Publication Year:

Abstract (2. Language): 
In this study, an analysis based on the first and second laws of thermodynamics, considering different environmental temperature, are performed for a natural gas fired combined cycle power plant. The variations of the performance parameters and their magnitudes are studied. The useful power, reversible power and irreversibility are obtained for each component which constitutes the plant, and overall efficiencies of the plant are also calculated. With a rise of 42 oC in the environmental temperature, the overall first and the second law efficiencies of the plant decreases about 4% and 5% , respectively. By the increase of environmental temperature from 0oC to about 42oC, the results indicated that both the reversible work and power out put of the system decrease about 22%, whereas specific fuel consumption increases about 9%.
Abstract (Original Language): 
Bu çalışmada doğal gaz yakıtlı bir kombine çevrim güç santralinin çevre sıcaklığına bağlı olarak performans parametrelerinin değişimi ve değişim miktarları termodinamiğin birinci ve ikinci kanunları kullanılarak analiz edilmiştir. Çalışmada sistemi oluşturan her bir ünitedeki faydalı güç, tersinir güç ve tersinmezlik miktarları tespit edilmiş ve sistemin genel verimleri hesaplanmıştır. Sistemin birinci kanun verimi ve ikinci kanun verimi çevre sıcaklığının 42ºC lik artışında sırasıyla %4 ve %5 oranında azaldığı hesaplanmıştır. Atmosferik hava sıcaklığındaki artışın sistemin genel verimini olumsuz olarak etkilediği sıcaklığın 42ºC artması santral net güç çıkışını %22 oranında azalttığı ve özgül yakıt sarfiyatını %9 oranında arttırdığı görülmüştür.
49-58

REFERENCES

References: 

1. BHARGAVA,R., M.BIANCHI., A.PERETTO. and P.R.SPINA. 2002. A fisibility study of existing gas turbines
for recuperated intercooled and reheat cycle. ASME TURBO EXPO 2002, Amsterdam, June 3-6 2002.
2. BHARGAVA,R. and C.B.MEHER-HOMJI. 2002. Parametric analysis of existing gas turbine with inlet
evaporative and over spray fogging. ASME TURBO EXPO 2002, Amsterdam, June 3-6 2002.
3. ÇENGEL,Y. and M.A.BOLES, 2002. Thermodynamics An Engineering Approach. Mc Graw Hill, 4th Edition,
Boston. 930 s.
4. EL-WAKIL,M.M. 1984. Power plant Technology. Mc Graw Hill, International Edition, New York.861 p.
5. ERDEM,H.H., S.H.SEVİLGEN., A.V.AKKAYA. ve A.DAĞDAŞ. 2003 Gaz türbinli sistemlerde çevre sıcaklığının
performansa etkisi. 14. Ulusal Isı Bilimi ve Tekniği Kongresi. Isparta, ULIBTK’03, 3-5 Eylül 2003.
6. FISCHI,D. and G.MANFRIDA. 1998. Exergy analysis of semi-closed gas turbine combined cycle (SCGT/CC).
Energy Conv. and Management, Vol.39,No.16-18, pp1643-1652.
7. KIM,T.S., H.J.PARK. and S.T.RO 2001. Characteristic of trasient operation of a dual-pressure bottoming system
for combined cycle power plant. Energy, 26: 905-918.
8. KOTAS,T.J. 1995. The exergy method of thermal plant analysis. Krieger. Malabar, Florida.328p.
9. NIXDORF,M., A.PRELIPCEANU and D.HEIN. 2002. Thermo economic analysis of inlet air conditionnig
methods. ASME TURBO EXPO 2002, Amsterdam, June 3-6 2002.
10.ROSEN,M.A. and I.DINCER. 1996. Energy and Eksergy analysis of sectoral energy utilisation an application for
Turkey. The Fist Trabzon International Energy and Environment Symposium, KTU Trabzon, 29-31 July 1996.
11.ÜNVER.Ü., 2004. Doğalgaz çevrim santralinin meteorolojik şartlara bağlı olarak termodinamik analizi. Doktora
Tezi. Bursa.165s.

Thank you for copying data from http://www.arastirmax.com