In this study, computer-aided modeling and analysis of a crowned tooth were made by using the finite element method. The tooth examined was the first central tooth. Prepared tooth and crowned tooth models obtained from Prosthesis Department of Dentistry Faculty- Ege University, were scanned in a 3-dimensional coordinate measuring machine (3D-CMM). In this way, the most suitable tooth geometry was determined. Scanned contours obtained by 3-D CMM were exported into I-DEAS Master Series (Integrated Design, Engineering and Analysis Software). Based on the shape of the prepared tooth, the chamfer model was constructed. The Finite Element Method was used due to the complicated geometry of the tooth. The behaviour of IPS Empress under loading was investigated in this study.
Abstract (Original Language): 
Bu çalışmada sonlu elemanlar yöntemi kullanılarak kron kaplamalı bir dişin bilgisayar destekli modelleme ve analizi yapılmıştır. İncelenen diş birinci keser santral diştir. Ege Üniversitesi Diş Hekimliği Protez Anabilim Dalı’ndan sağlanan kesik ve kaplamalı diş modelleri 3-boyutlu ölçüm cihazında taranmıştır. Bu şekilde, diş geometrisi en uygun şekilde belirlenmiştir. 3-boyutlu koordinat ölçüm cihazından elde edilen konturlar, I-DEAS Master Series (Integrated Design, Engineering and Analysis Software) paket programına aktarılmıştır. Kesik dişin basamak şekline bağlı olarak, geniş açılı (chamfer) diş modeli hazırlanmıştır. Dişin karmaşık bir geometriye sahip olması sebebiyle, Sonlu Elemanlar Yöntemi kullanılmıştır. Kullanımı henüz yaygınlaşmaya b
75-83

REFERENCES

References: 

Balatlıoğlu A. (2000): “In Vitro Olarak Hazırlanan Alt Tam Protez Ve Destek Yapıların Üç
Boyutlu Matematik Modelinin Oluşturulması”, İstanbul, İ.T.Ü Makina Fakültesi
Biyomekanik Sempozyumu, s. 29-43
Farah J.W., Dennison J.B., Powers J.M. (1997): “Effects of Designing on Stress
Distributionof Intracoronal Gold Restorations”, Journal of American Dental Association,
94, 1151.
Hübsch P.F., Middleton J., Knox J. (2000): “A Finite Element Analysis of the Stress at the
Restoration-tooth Interface”, Comparing Inlays and Bulk Fillings, Biomaterials, 21, 1015-
1019.
Hwang W.J., Yang J. (2001): “Fracture Strength of Copy-milled and Conventional In-Ceram
Crowns”, Journal of Oral Rehabilitation, 28, 678-683.
Joshi S., Mukherjee A., Kheur M., Mehta A. (2001): “Mechanical Performance of
Endodontically Treated Teeth”, Finite Elements in Analysis and Design, 37, 587-601.
Nakamura T., Imanishi A., Kashima H., Ohyama T., Ishigaki S. (2001): “Stress Analysis of
Metal–Free Polymer Crowns Using the Three–Dimensional Finite Element Method”, The
International Journal of Prosthodontics, 14, 401-405.
Pekbey Y. (2002): “Değişik Türden Malzeme İle Kaplanmış Dişin Gerilme Zorlanma
Analizi”, Yüksek Lisans Tezi, D.E.Ü. Fen Bilimleri Enstitüsü, Mekanik Anabilim Dalı,
İzmir.
Rudolph D.J., Willes M.G., Sameshima G.T. (2001): “A Finite Element Model of Apical
Force Distribution from Orthodontic Tooth Movement”, Angle Orthodontist, 71, 127-131.

Thank you for copying data from http://www.arastirmax.com