You are here

Sekundum atriyal septal defektli çocuklarda miyokard performans indeksi

Myocardial performance index in children with secundum atrial septal defect.

Journal Name:

Publication Year:

Abstract (2. Language): 
Ouantitatİve assessment of ventricular function in patients with congenital heart disease is often challenging due to distorted ventricular geometry. A myocardial performance index ( MPI} has been reported in adults and children that is a Doppler-derived non-geometric measure of ventricular function. The MPI measures the ratio of İsovolumic time intervals to ventricular ejection time. The effects of altered ventricular preload or afterload on the MPI have yet to be determined. Thİs study was designed to determine the impact of altered preload on left and right ventricular MPI in the clinical setting of atrial septal defect (ASD j. The left and right ventricular MPI were measured in 17 patients with ASD(ages 6 to 148 months, median 24 months j, and24 normal childrenfages 3 to 160 months, median 17monthsj. İn patients with ASD and control groups, the left ventricular MPI was 0.38±0.16 and 0.32±0.09, and the right ven¬tricular MPI was 0.24±0.15 and 0.20+0.08 respectively. No significant change in the left and right ventricular MPI was seen in patients vvith atrial septal defect and control groups. This study documents that the MPI is a çuantitative mea¬sure of ventricular function that is appears to be relatively independent of changes in preload.
Abstract (Original Language): 
Doğuştan kalp hastalığı olan hastalarda ventrikül geometrisi bozulacağı için ventrikül fonksiyonlarını değerlendirmede bazı zorluklar olabilmektedir. Ventrikül fonksiyonlarını değerlendirmede Doppler eko yöntemi ile elde edilen ve ven-trikülün geometrik şekline bağımlı olmayan miyokard performans indeksi erişkin ve çocuklarda araştırılarak kullanılmaya başlanmıştır Miyokard performans indeksi izovolumik zaman aralıklarının ventrikül ejeksiyon zamanına bölünmesi ile elde edilir. Ventriküilerin ön ve art yük değişikliklerinde bu indeksin nasıl etkilendiği araştırılmalıdır. Bu çalışma atriyal septal defektin (ASD) neden olduğu ön yük değişikliklerinde sağ ve sol ventriküler miyokard performans indeksinin nasıl etkilendiğini araştırmak amacı ile planlandı. Yaşları 6 ay ile 148 ay arasında ( ortanca 24 ay) 17 ASD' li ve yaşlan 3 ay ile 160 ay arasında ( ortanca 17 ay j 24 normal çocukta sol ve sağ ventrikül için miyokard performans indeksi ölçüldü. Sol ventrikül için miyokard performans indeksi ASD ve kontrol grubunda sırası ile 0.38±0.16 ve 0.32±0.09 iken sağ ventrikül için miyokard performans İndeksi sırası ile 0.24±0.15 ve 0.20±0.08 bulundu. Gruplar arasında sol ve sağ ventrikül miyokard performans indeksleri yönünden istatiksel açıdan anlamlı bir fark yoktu (p < 0.05 } . Bu çalışma ile ventrikül fonksiyonlarını ölçmeye yarayan miyokard performans İndeksinin ASD' li hastalarda ön yük değişikliklerinden etkilenmediği gösterildi.
109-114

REFERENCES

References: 

1. Bruch C, Schmermund A Marin D, Katz M, Bartel T, Schaar J, Erbel R. Tei index in patients with rnild-tomoderate congestive heart failure. EurHeartJ 2000; 21: 1888-95.
2. Sutton MSJ, Wiegers SE. The Teî index- a role in the diag-nosis of heart faîlure? Eur Heart J 2000; 21:1822-4.
3. Eîdem BW, Tei C, O'leary PW, Cetta F, Seward JB. Nongeometric quantitative assessment of right and left ventricular function: myocardial performance îndex in normal children and patients with Ebstein anomaly. J Am Soc Echocardiogr 1998; 11: 849-56.
4. Eidem BW, O'leary PW, Tei C. Seward JB. Usefulness of the myocardial performance index for assessing right ven¬tricular function in congenital heart disease. Am J Cardiol 2000; 86: 654-8.
5. Williams RV, Ritter S, Tani LY, Pagotto LT, Minich LL Ouantitative assessment of ventricular function in children with single ventricles using the Doppler myocardial per¬formance İndex. Am J Cardiol 2000; 86: 1106-10.
6. Sahn DJ. De Maria A Kisslo J, Weyman A. The committee on m-mode standardisation of the American Society of Echocardİography: results of a survey of echocardio-graphic measurements. Circulation 1978; 58: 1072-83.

7. Dujardin kS, Tei C, Yeo TC, Hodge DO, Rossi A Sevvard JB.
Prognostic value of a doppler index combining systolic and diastolic performance in idiopathic-dilated cardiomy-opathy. Am J Cardiol 1998; 82: 1071-6.
8. Moller JE, Poulsen SH. Egstrup K. Effect of preload alter-nations on a new Doppler echocacrdiographic index of combined systolic and diastolic performance. J Am Soc Echocardiogr 1999; 135: 1065-72.
9. Harjai KJ, Scott L, Vivekananthan K, Nunez E. Edupuganti R. The Tei index: a new prognostic index for patients with symptomatic heart failure. J Am Soc Echocardiogr 2002; 15:864-8.
10. Tei C, Dujardin KS, Hodge DO, Kyle RA, Tajik AJ, Sevvard JB. Doppler index combining systolic and diastolic myocardial performance: dinical value in cardiac amyloi-dosis. J Am Coll Cardiol 1996; 28: 658-64.

11. Yeo TC, Dujardin KS, Tei C, Mahoney MD, Sevvard JB. Value of a doppler-derived index combining systolic and diastolic time intervals in predicting outcome in primary pulmonary hypertension. Am J Cardiol 1998; 81: Jl 57¬61
12.Tei C, Dujardin KS, Hodge DO, Kyle RA McGoon MD. Tajik AJ, Seward JB. Doppler echocardiographic ındex for assessment of global right ventricular function. J Am Soc Echocardiogr 1996; 9: 838-47.
13. Zile fviR, Brutsaert DL. New contepts in diastolic dysfunc-tiön and diastolic heart failure: part 1. Circulation 2002; 105: 1387-93
14.Hahn HS, Hoiî BD. Doppler echocardiographic assess¬ment of diastolic ventricular function: transmitra! and pui-monary venous flow indıces. Prog Ped Cardiol 1999; 10: 95-103.
!5.Abd Ei Rahman MY, Abdul-Khaliq H, Vogel M, Alexi-Mesfelschvill, Gutberlet M, Hetzer R. Lange PE. Value of the new doppler derived myocardial performance index for the Evaluauon of right and left ventricular function fol-lowing repar of ceiralogy of fallot. Pediatr Cardiol 2002; 23: 502-7