You are here

EGE BÖLGESİNDEKİ İLLERDE PENCERELER İÇİN OPTİMUM HAVA TABAKASI KALINLIĞININ ARAŞTIRILMASI

INVESTIGATION OF OPTIMUM AIR GAP THICKNESS FOR WINDOWS IN PROVINCES OF THE AEGEAN REGION

Journal Name:

Publication Year:

Abstract (2. Language): 
In this study the effects of varying the air gap on insulation of window which is air layer between two glass plates in a vertical position starting from 1 mm to 280 mm are researched for eight provinces in the Aegean region. Optimum air gap for windows is enhanced based on the results of this study. With this approach, optimum air gap are calculated as follows: 14 mm for İzmir, 13 mm for Denizli, 12.5 mm for Uşak, 13.4 mm for three provinces (Aydın, Manisa, Muğla) with the same exterior temperature, and 12.2 mm for two provinces (Afyon, Kütahya). This study introduces optimum air gap approach for each province in the Aegean region.
Abstract (Original Language): 
Bu çalışmada Ege Bölgesi’ndeki sekiz (Manisa, İzmir, Kütahya, Uşak, Afyon, Aydın, Denizli, Muğla) il için düşey konumda iki cam plaka arasındaki hava tabakası 1 mm’den başlayıp 280 mm’ye kadar hava boşluğunun penceredeki yalıtıma etkileri araştırılmıştır. Araştırma sonuçlarına göre; Ege Bölgesi’ndeki iller için pencerelerde optimum hava boşluğu yaklaşımı getirilmiştir. Bu yaklaşımla İzmir’de 14 mm, Denizli’de 13 mm, Uşak’ta 12,5 mm ve dış hava sıcaklığı aynı olan üç ilde (Aydın, Manisa, Muğla) 13,4 mm ve iki ilde (Afyon, Kütahya) 12,2 mm olarak optimum hava tabakası kalınlığı hesaplanmıştır. Bu çalışma ile literatüre Ege Bölgesi’ndeki her il için optimum hava tabakası kalınlığı yaklaşımı getirilmiştir.
60
64

REFERENCES

References: 

[1] http://www.haberbilgi.com/bilim/cevre/kuresel_isin
ma03.html, [Date of access: 23.07.2015].
[2] Arısoy A., TTMD Eskişehir Çalıştayı, Şubat 2009.
[3] www. tuik. gov.tr, [Date of access: 23.07.2015].
[4] Ogulata, G., “Sectoral energy consumption in Turkey”, Renewable and Sustainable Energy Reviews, 6, 471–480, 2002.
[5] Kaygusuz K., Kaygusuz A., “Energy and sustainable development. Part II: Environmental impacts of energy use”, Energy Sources, 26, 1071–1082, 2004.
[6] Al-Homoud, M.S., “Performance characteristics and practical applications of common building thermal insulation materials”, Building and Environment, 40, 353–366, 2005.
[7] Ertürk M., Pul H., Keçebaş A., Uygunoğlu T., Daşdemir A., “İl Bazında Çift ve Üç Camlı Pencereler İçin Optimum Hava Tabakası Kalınlığı Analizi”, 12. National Installation Engineering Congress and Exhibition, 8-11 April 2015, İzmir, Turkey, 2953–2965.
[8] www.enerji.gov.tr, [Date of access: 11.07.2015].