[1] Oztekin Y, Tok M, Nalvuran H, Kiyak S, Gover T, Yazicigil Z, Ramanaviciene A, Ramanavicius A. “Electrochemical modification of glassy carbon electrode by poly-4-nitroaniline and its application for determination of copper (II)”. Electrochimica Acta, 56(1), 387-395, 2010.
[2] Oztekin Y, Krikstolaityte V, Ramanaviciene A, Yazicigil Z, Ramanavicius A. “1,10-Phenanthroline derivatives as mediators for glucose oxidase”. Biosensors and Bioelectronics, 26(1),267-270, 2010.
[3] Goyal RN, Oyama M, Gupta VK, Singh SP, Sharma RA. “Sensors for 5-hydroxytryptamine and 5-hydroxyindole acetic acid based on nanomaterial modified electrodes”. Sensors and Actuators B: Chemical, 134(1), 816-821, 2008.
[4] Deinhammer RS, Ho M, Anderegg JW, Porter MD. “Electrochemical oxidation of amine-containing compounds: a route to the surface modification of glassy carbon electrodes”. Langmuir, 10(1), 1306-1313, 1994.
[5] Downard AJ, Tan ESQ, Yu SSC. “Controlled assembly of gold nanoparticles on carbon surfaces”. New Journal of Chemistry, 30(1), 1283-1288, 2006.
Pamukkale Univ Muh Bilim Derg, 23(7), 874-876, 2017
H. Yüksek, M. Alkan, Ş. Bahçeci, O. Akyıldırım, M. Beytür, M. L. Yola
876
[6] Sullivan MG, Schnyder B, Bartsch M, Alliata D, Barbero C, Imhof R, Kotz R. “Electrochemically modified glassy carbon for capacitor electrodes characterization of thick anodic layers by cyclic voltammetry, differential electrochemical mass spectrometry, spectroscopic ellipsometry, X-ray photoelectron spectroscopy, FTIR and AFM”. Journal of the Electrochemical Society, 147(2), 2636-2643, 2000.
[7] Tsierkezos NG, Ritter U. “Application of electrochemical impedance spectroscopy for characterisation of the reduction of benzophenone in acetonitrile solutions” Physics and Chemistry of Liquids, 49(2), 729-742, 2011.
[8] Liao HC, Jiang SJ. “Determination of cadmium, mercury and lead in coal fly ash by slurry sampling electrothermal vaporization inductively coupled plasma mass spectrometry”. Spectrochimica Acta Part B: Atomic Spectroscopy, 54(1), 1233-1242, 1999.
[9] Bortoleto GG, Macarovscha GT, Cadore S. “Determination of cadmium by flame-atomic absorption Spectrometry after preconcentration on silica gel modified with cupferron”. Journal Brazilian Chemical. Society, 15(2), 313-317, 2004.
[10] Mhammedi MAE, Achak M, Hbid M, Bakasse M, Hbid T, Chtaini A. “Electrochemical determination of cadmium(II) at platinum electrode modified with kaolin by square wave voltammetry”. Journal of Hazardous Materials, 170(1), 590-594, 2009.
[11] Liu M, Feng Y, Wang G, Fang B. “Determination of cadmium(II) using glassy carbon electrodes modified with cupferron, ß-naphthol, and multiwalled carbon nanotubes”. Microchimica Acta, 177(1), 221-228, 2012.
[12] Guo J, Luo Y, Ge F, Ding Y, Fei J. “Voltammetric determination of cadmium (II) based on a composite film of a thiol-functionalized mesoporous molecular sieve and an ionic liquid”. Microchimica Acta, 172(1), 387-393, 2010.
[13] Yola ML, Atar N, Qureshi MS, Üstündağ Z, Solak AO. “Electrochemically grafted etodolac film on glassy carbon for Pb(II) determination”. Sensors and Actuators B: Chemical, 171-172(1), 1207-1215, 2012.
[14] Yüksek H, Küçük M, Alkan M, Bahçeci S, Kolayli S, Ocak Z, Ocak U, Sahinbas E, Ocak M. “Synthesis and antioxidant activities of some new 4-(4- hydroxybenzylidenamino)-4,5-dihydro-1H-1,2,4-triazol-5-one derivatives with their acidic properties". Asian Journal of Chemistry, 18(1), 539-550, 2006.
Thank you for copying data from http://www.arastirmax.com