Buradasınız

MAKSİMUM GÜÇ NOKTASI İZLEYİCİLİ FOTOVOLTAİK SİSTEMLERİN OPTİMUM DİZAYN VE ÇALIŞMA KOŞULLARININ ARAŞTIRILMASI

INVESTIGATION OF OPTIMUM DESIGN AND OPERATION CONDITIONS OF PHOTOVOLTAIC SYSTEMS WITH MPPT

Journal Name:

Publication Year:

Abstract (2. Language): 
In this study, optimum design conditions are investigated for a photovoltaic (PV) configuration that uses a maximum power point tracker (MPPT). The configuration is used for providing constant power at the optimum output values of voltage and current. The main objective here is to minimize the number of PV modules to be used for the specified power output. Theoretical analysis consisting of three basic phases is made for constant latitude angle by using monthly average values of meteorological data. In first two phases, respectively, design conditions to maintain maximum values of radiation and utilizability are determined. The optimum values of voltage and current for these design conditions of the PV array with MPPT are then evaluated. The method and constructed diagrams given here makes the selection of optimal PV array configuration relatively easier.
Abstract (Original Language): 
Bu çalışmada, maksimum güç noktası izleyicili (MPPT) PV kombinasyonlarının sabit güç temini için kullanımına yönelik optimum çalışma şartları araştırılmaktadır. Çalışmanın temel amacı; gereksinim duyulan gücü minimum sayıda PV panel kullanarak temin etmektir. Çalışma üç temel aşamadan oluşmakta olup, sunulan analizler aylık ortalama değerler bazında ve sabit enlem açısı şartlarında yapılmıştır. İlk iki aşamada sırasıyla maksimum toplam radyasyon açı faktörünü ve maksimum kullanılabilirliği sağlayan dizayn koşulları tespit edilmiştir. Daha sonra bu dizayn koşullarında MPPT yardımıyla PV panellerden elde edilebilecek maksimum volt ve akım değerleri tespit edilmiştir. Çalışmada sunulan yöntem ve diyagramlar yardımıyla optimum panel konfigürasyonunun kolaylıkla belirlenmesi mümkündür.
FULL TEXT (PDF): 
147 – 158

REFERENCES

References: 

Al-Ibrahim A.M., Beckman W.A., Klein S.A., “Desing Procedure for Selecting an Optimum
Photovoltaic Pumping System in a Solar Domestic Hot Water System”, Solar Energy,
Vol.64, pp. 227-239, 1998.
Al-Karaghoulı, A., Al-Sabounchı., A. M., “A PV Pumping System”, Applied Energy, Vol.65,
pp. 145-151, 2000.
Agha K. R., Sbita M. N., “On the Sizing Parameters for Stand-Alone Solar-Energy
Systems”, Applied Energy, Vol.65, pp. 73-84, 2000.
Al-Shaban S., Mohmoud A., “ Self-Control in Storage Unit of PV Plants”, Applied Energy,
Vol. 65, pp. 85-90, 2000
Beckman W.A., Beckman S. A., Duffic J. A., “A Dising procedure for Solar Heating
Systems”, Solar Energy, 1979;18:113.
Bloos, H., “ Analytical and Exerimental İnvestigation of Photovoltaic Pumping Systems”, Doctor
Thesis, University of Oldenburg, 2000.
Dinçer, B., “Optimum Tilt angle for Solar Collectors Used in Cyprus”, Solar Energy, Vol. 6, pp. 813-819, 1995.
Duffıe, J., Beckman, W.A., Solar Engineering of Thermal Processes, 2nd edn., Wiley
Interscience, 1991.
Fıratoğlu, Z., A., Yeşilata, Bülent, “Fotovoltaik Güç Destekli Dalgıç Pompa Sistemlerinde
Optimum DizaynKoşullarının Araştırılması”, Tesisat Mühendisliği Dergisi, Sayfa:59-66
Nisan-Mart 2001.
Hsieh S.J., Solar Energy Engineering, Prentice-Hall, Inc, Englewood Cliffs, New Jersey,
1986.
Kılıç A., Öztürk A., Güneş Enerjisi, Kipaş Yayıncılık, 1983.
Kou S.A., Kleın A., Beckman W., “ A Method for Estımatıng the Long-Term Performance of
Dırect- Coupled PV Pumpıng Systems”, Solar Enery, Vol. 64, pp.33-40, 1998.
Muntasser, M.A. , Bara, M.F., Quadri , H.A. , EL-Tarabelsi, R., La-azebi, I.F., “Photovoltaic
Marketing İn Developing Countries”, Applied Energy, Vol. 65, pp 67-72, 2000.
Veerachary, M., Yadaıah, N., “Ann Based Peak Power Tracking for Supplied DC Motors”,
Solar Energy, Vo. 69, pp. 343-350, 200l.
Yeşilata, B., Aktacir, M.A., “ Fotovoltaik Güç Sistemli Su Pompalarının Dizayn Esaslarının
Araştırılması”, Mühendis ve Makine, cilt 42, sayı 493, sy 29-34, 2000.
Zaki A. M., Eskander M. N., “ Matching of Photovoltaic Motor-Pump Systems for
Maximum “, Efficiency Operation”, Renewable Energ, Vol. 7, pp. 279-288, 1996.

Thank you for copying data from http://www.arastirmax.com