Buradasınız

BİR ÇİMENTO DÖNER FIRIN SİSTEMİ YÜZEYİNDEN ISI KAYIPLARININ AMPİRİK VE İSTATİSTİKİ MODELLENMESİ

EMPIRICAL AND STATISTICAL MODELING OF HEAT LOSS FROM SURFACE OF A CEMENT ROTARY KILN SYSTEM

Journal Name:

Publication Year:

Abstract (2. Language): 
In branches of industry too much energy consuming such as cement sector, controlled use of energy, only it is possible to know how energy is distributed in the system. In cement production process, a large portion of the heat losses which is due to energy consumption consist of convection and radiation heat losses from the surface of rotary kiln. In this study, empirical equation was derived for heat loss from surface of rotary kiln in a cement factory using empirical equations and statistical modeling techniques by the help of temperatures measured surface of rotary kiln. Measured with thermal cameras and the data necessary for experimental modeling was obtained the factory central control room. Total heat loss of system was calculated using Matlab. Statistical analysis related to results was carried out by Minitab 15.1.1 program. It was concluded that heat losses throughout rotary kiln increased toward the center of the kiln.
Abstract (Original Language): 
Çimento sektörü gibi üretimde çok fazla enerji tüketen sanayi dallarında, enerjinin kontrollü kullanımı, ancak enerjinin sistemde nasıl dağıldığının bilinmesi ile mümkün olur. Çimento üretim prosesinde enerji tüketiminin nedeni olan ısı kayıplarının büyük bölümünü, döner fırın yüzeyinden konveksiyon ve radyasyon ile olan ısı kayıpları oluşturmaktadır. Bu çalışmada, döner fırın yüzeyinden ölçülen sıcaklıklar yardımıyla fırın boyunca ısı kaybı için ampirik denklem ve istatistiki modelleme teknikleri kullanarak ampirik denklem türetilmiştir. Termal ölçüm kameraları ile ölçülen ve deneysel modelleme için gerekli olan veriler, fabrika merkezi kontrol odasından alınmıştır. Sistemin toplam ısı kaybı Matlab programı kullanarak hesaplanmıştır. Sonuçlar ile ilgili istatistiksel analizler Minitab 15.1.1 programı ile gerçekleştirilmiştir. Fırın boyunca ısı kayıplarının özellikle fırın merkezine doğru arttığı sonucuna ulaşılmıştır.
59
66

REFERENCES

References: 

1. Pelletier,L., Winnefeld F. ve Lothenbach,
B.,”The ternary system Portland cement–
calcium sulphoaluminate clinker–anhydrite:
Hydration mechanism and mortar properties”,
Cement & Concrete Composites, Vol 32, 497–
507, 2010.
2. Schneider, M., Romer, M., Tschudin, M. ve
Bolio, H.,”Sustainable cement production—
present and future”, Cement and Concrete
Research, Vol 41, 642–650, 2011.
3. Montgomery, D.C. ve Runger C.R., Applied
Statistics and Probability For Engineers, 4.th,
John Wiley and Sons, USA, 2006.
4. Sonavane, Y., Specht, E.,”Numerical analysis of
the heat transfer in the wall of rotary kiln using
finite element method ANSYS”, Seventh
International Conference on CFD in the
Minerals and Process Industries, CSIRO,
Melbourne, Australia, 9-11 December 2009.
5. Engin,T.”Çimento Fabrikalarındaki döner fırın
sistemlerinin ısıl analizi”, 1.Makina
Mühendisliği Kongresi, İ.T.Ü Makine
Fakültesi, İstanbul, 29-35, 4-6 Haziran1997.
6. Engin,T., Ari,V.,” Energy auditing and recovery
for dry type cement rotary kiln systems:A case
study”, Energy Conversion and Management,
Vol 46, 551–562, 2005.
7. Specht, E., Shi, Y.C., Woche, H., Knabbe, J. ve
Sprinz, U.,”Experimental investigation of solid
bed depth at the discharge end of rotary
kilns”,Powder Technology, Vol 197, 17-24,
2010
8. Stadler, S.K., Poland, J. ve Gallestey E.,” Model
predictive control of a rotary cement
kiln”,Control Engineering Practice, Vol 19, 1–
9, 2011.
9. Caputo, C.A., Pelagagge, M.P. ve Salini
P.,”Performance modeling of radiant heat
recovery exchangers for rotary kilns”, Applied
Thermal Engineering, Vol 31, 2578-2589,
2011.
10. Gryna, M.F., Chua, C.R. ve Defeo A.J., Juran’s
Quality Planning and Analysis for Enterprise
Quality, 5.ed, McGraw-Hill, USA, 2007.
11. Mujumdar, S.K., Ganesh, K.V., Kulkarni, S.B.
ve Ranade V.V., ”Rotary Cement Kiln Simulator
(RoCKS): Integrated modeling of pre-heater,
calciner, kiln and clinker cooler”, Chemical
Engineering Science, Vol 62, 2590 – 2607,
2007.
12. Walpole, E.R, Myers, H.R., Myers, L.S. ve Ye,
K., Probability & Statistics for Engineers &
Scientists,8 ed, Pearson Prentice Hall, Upper
Saddle River,New Jersey, 2007.
13. Hicks, C.R. Deney Düzenlemede İstatistiksel
Yöntemler, Çeviren: Muluk, Z., Toktamış, Ö.,
Kurt, S. ve Karaağaoğlu, E., Gazi Kitabevi,
Ankara, 2009.
14. Lüküslü, D., Modelleme Sürecinde Weibull
Dağılımının Kullanılması, Yüksek Lisans Tezi,
Marmara Üniversitesi, Fen Bilimleri Enstitüsü,
2005.
15. Liu, X.Y. ve E. Specht,” Temperature
distribution within the moving bed of rotary
kilns: Measurement and analysis”, Chemical
Engineering and Processing, Vol 49, 147–150,
2010.
16. Holman, J.P., Heat Transfer, 10th ed, McGraw
Hill Company, NY, 2010.
17. Montgomery,C.D., Statistical Quality Control:
A Modern Introduction, 6Edition, John
Wiley& Sons., USA, 2009.
18. Madhool, N.A., Saidur, R., Hossain, M.S.,
Rahim, N.A.,”A critical review on energy use
and savings in the cement industries”,
Renewable and Sustainable Energy Reviews,
Vol 15, 2042–2060, 2011.

Thank you for copying data from http://www.arastirmax.com