The laser power source is one of the key equipments of the power supply module (PSM), which is crucial to transmit the energy efficiently with high stability and reliability. Therefore, it is important to measure the pulse current quickly with high reliability and accuracy. A novel opto-electronic current transducer (OECT) based on Rogowski coil is demonstrated to measure high-power high-voltage laser source. The CT is placed in the high-voltage side and is used to measure different durations of pulse current with large amplitude for the laser power source. Models with lumped parameters and dynamitic properties of the Rogowski coil with a new type of integrator have been analyzed in detail. The optimizing parameters of the transducer have been introduced. Measurement results of the opto-electronic current measurement instrument are described respectively. The simple sensor geometry gives high accuracy and sensitivity, wide dynamic range, and immunity from slow-variance temperature.
835-841

REFERENCES

References: 

1. W. Stygar and G. Gerdin, “High frequency Rogowski coil response characteristics”, IEEE Trans on Instrument & Measurement, Vol: 10, No: 1,pp. 40-44, 1992.
2. G.R. Turner and I.W. Hofsajer, “Rogowski coils for short duration (<10μs) pulsed current (>10 kA) measurements”, IEEE Industry Applications Conference, African, No: 2, pp. 759 –764, 1999.
3. D.L. Smith, J.M. Wilson, H.C. Harjes, W.B.S. Moore, J. Hammon, “FANTM: the first article NIF test module for the laser power conditioning system”, 12th IEEE International Pulsed Power Conf., Monterey, Calif. USA, Vol.2, pp. 921-924, 1999.
4. R.A. Richardson, W.R. Cravey, D.A. Goerz, “Performance Of A 10 KV, 625 KA, 85 KJ Energy Discharge Module Utilizing A Solid Dielectric Switch”, 8th IEEE International Pulsed Power Conf., pp. 187-190, 1991.
5. T.W. Cease, P.A. Johgnston, “A magnetic-optic current transducer”, IEEE Tans on Power Delivery, Vol: 5, No: 2, pp. 548-555, 1990.
6. A. Cruden, Z.J. Richardson, J.R. McDonald, I. Andonovic, “Compact 132kV combined optical voltage and current measurement system”, IEEE Trans on Instrument & Measurement, Vol: 47, No: 1, pp. 219-223, 1998.
7. W.F. Ray and C.R. Hewson, “Rogowski transducers for measuring large magnitude short duration pulses”, IEE Symposium Pulsed Power, pp.1–23, 2000.
8. D A Ward and J La T Exon, “using Rogowski coils for transient current measurements”, IEEE science and Eng. Journal, Vol: 2, No: 3, pp. 105 –113, 1993.
9. Li Weibo, Mao Chengxiong, Li Qiyan, Yao Zonggan, Fan Shu, The Simulation Research of Rogowski Coils for Measuring High-speed and Heavy pulsed current. High voltage Engineering, Vol.28, No: 8, pp. 11-13, 2002.
10. Weibo Li, Chengxiong Mao, “Research of on-line monitoring technology with the new magnetic potentiometer”, Journal of Transducer Technology, Vol: 20, No: 11, pp. 14-17, 2001.
11. Weibo Li, Qiyan Li, “Application of the magnetic potentiometer in inspecting the dilapidation of the electrobath of the Aluminum”, Journal of Sichuan University of Science & Technology, Vol: 19, No: 4, pp.22-27, 2000.
12. A. Radun. “An alternative low-cost current-sensing scheme for high current power electronics circuit” IEEE Trans & Electron, Vol: 42, No: 1,pp. 78–84, 1995.
13. Ljubomir Kojovic, “Rogowski coils suit relay protection and measurement”, IEEE Computer Application in Power, Vol: 10, No: 3, pp. 47-52, 1997.

Thank you for copying data from http://www.arastirmax.com