You are here

Management of dorsally displaced distal radius fracture by volar fixation using locking compression plate.

Management of dorsally displaced distal radius fracture by volar fixation using locking compression plate.

Journal Name:

Publication Year:

Abstract (2. Language): 
Introduction: Dorsally angulated and displaced fractures of distal radius are common and tend to suffer secondary treatment after conservative treatment. Present study was planned to evaluate the functional and radiological results of treating unstable dorsally displaced fractures of distal radius with locking compression plate Material & methods: 25 cases of dorsally displaced distal radius fractures (9 men and 16 women; mean age ,49.8 years) were fixed by volar locking compression plate and followed up followed for six months minimum. Results: Lidstorm’s anatomical criteria showed 23 grade I (excellent) and 2 grade II (good) results while functional results 10 excellent, 10 good outcome while 3 patients exhibiting fair & 2 poor results. Only one patient had superficial infection. Conclusion: From present study we may conclude that volar locking plate is a safe and effective treatment for dorsally displaced unstable fractures of distal end radius
419-425

REFERENCES

References: 

1: KK Wong, KW Chan, TK Kwok, KH Mak. Volar fixation of dorsally displaced distal radial fracture using
locking compression plate.J. of ortho. Surg.2005;13(2):153-157
2: Ring D, Jupiter JB, Tan V, Distal radius plating options. Curr Opin Ortho 2003;14:238-44
3: Campbell DA. Open reduction and internal fixation of intra articular and unstable fractures of the
distal radius using the AO distal radius plate. J Hand Surg Br 20000;25;528-34
4: ACOB m, Rikki DA, Regazzoni P. Fractures of the distal end of radius treated by internal fixation and
early function. A prospective study of 73 patients J. Bone Joint Surg Br 2000;82:340-344
5: Chan KW, Kwok TK, Mak KH. Early experience with locking compression plate in the treatment of
distal radius fracture, Hong Kong J of orthop surg 2003;7: 88-93
6: LEUNG f,Zhu L, Ho H, Lu WW, Chow SP. Palmar fixaion of AO type C2 fractures of distal radius using a
locking compression plate : a biomechanical study in cadaveric model J Hand Surg Br2003;8:263-
266
7: Cooney WP, Dobyns JH, Linscheid RL. Complications of Colles' fractures. J. Bone Joint Surg (Am) 1980
: 62(4) : 613-619.
8: Cooney WP, Dobyns JH, Linscheid RL. Complications of Colles' fractures. J. Bone Joint Surg (Am) 1980
: 62(4) : 613-619.
9: Orbay JL. Fernandez Dl. Volar fixed-angle plate fixation for unstable distal radius fractures in the
elderly patient. J. Hand Surg. (Am) 2004; 29. 96-102
10: Lidstorm: fractures of Distal end of Radius : A clinical and statistical study of End Results. Acta
Orthop Scand supplement, 41, 1959.
11: Kamano M, Honda Y, kazuki K, Yasuda M, Palmar plating for dorsally displaced fracture of distal
radius.Clin Orthop Relat Res 2002; 397:403-408
12: M. Rizzo, B.A. Katt, J.T. Carothers : Comparison of locked volar plating versus pinning and External
fixationin the treatment of unstable intra articular distal radius fractures. Hand (2008) 3: 111-117.
13: Kenichi Murakami, Yoshihiro Abe and Kazuhisa Takahoshi : Surgical treatment of unstable distal
radius fractures with volar locking plates.
14: Palmer AK. Fractures of the Distal radius. In operative Hand surger, Edition 2m Vol. 2, Page 1006-
1007, New York Churchill Livingstone, 1988.
15: K. Egol, M. walsh, N. Tejwani Bridging external fixation and supplementary Kirschner - wire fixation
Indian Journal of Basic & Applied Medical Research; December 2012: Issue-5, Vol.-2, P. 419-425
425
www.ijbamr.com
versus volar locked plating for unstable fractures of the distal radius : J. Bone Joint Surg (Br) 2008; 90-B
: 1214-1221.
16: W. Schemelzer - Schmied P. Wieloch A.K. Martini. Comparison of external fixation, locking and nonlocking
palmar plating for unstable distal radius fractures in the elderly. International orthopaedics
(SICOT) DOI 10.1007/S00264-007-0504-9.
17: y. Zenke, A. Sakai, T. O. Shige. The effect of an associated ulnar styloid fracture on the outcome after
fixation of a fracture of the distal radius. J. Bone Joint Surg. (Br) 2009 : 91-B : 102-107.
18: Erik D. Peterson, David G. Dennison. Fixed angle volar plate fixation for distal radius fractures in
Immuno suppressed patients. Hand (2008) 3 : 287-291.

Thank you for copying data from http://www.arastirmax.com