You are here

4- MET A SOĞUK AKRİLİK PROTEZ KAİDE REÇİNESİNİN PROTEZ KAİDE METALİNE BAĞLANMA DAYANIMI

BOND STRENGTH OF SELF-CURE 4-META ACRYLIC DENTURE BASE RESIN TO METAL DENTURE BASE

Journal Name:

Publication Year:

Abstract (2. Language): 
Chemical bonding of poly (methyl methacrylate) (PMMA) denture base resin to metal denture base was reported to be possible with addition of 4-META (4-methacrylox-yethyl trimellitate anhydrate) to monomer. In this study tensile bond strength of self-cure 4-META PMMA (Metaplast) and conventional self-cure PMMA (Meliodent) to a cobalt chromium denture base alloy (Wironit) was investigated. Three different surface preparations were: 1-electro-etched, 2- sandblasted and 3- retention mesh design (simulating cast framework). Specimens were stressed using Instron machine at Imm/min rate and bond strength values (kg.f) and failure types were recorded. Data were analysed using one-way ANOVA and t test (p<0.05). The highest mean bond strength value was seen when 4-Meta bonded with retention mesh (111.33 kg.f/cm2) and this was not statistically different from the mean value of 4-META bonded with sandblasted group (100.77 kg.f/cm2). The bond strength of 4-META was higher than Meliodent when bonded to, with retention mesh and sandblasted surfaces. It was concluded that, the bond strength of self-cure 4-META PMMA to the sandblasted metal bases was as sufficient as it is bond strength to the retention mesh of partial dentures.
Abstract (Original Language): 
Monomerine 4-META (4-metakriloksietİl trimellitat an-hidrat) katılmış olan akrilİk reçinelerin, metal protez kaidesine kimyasal olarak bağlanabildiğini bildiren araştırmalar bulunmaktadır. Bu çalışmada Metaplast isimli 4-META içeren soğuk tamir akriliğinin krom kobalt protez kaide metaline (Wironit) bağlanma dayanımı konvansiyonel soğuk akrilik Meliodent ile karşılaştırılarak çekme gerilimi ile incelenmiştir. Üç farklı bağlanma yüzeyi: 1-elektro "etching" yapılmış, 2-kumlanmış ve 3-retansiyon ağı ilave edilmiş yüzeylerdir. İnstron test cihazında 1 mm/dak'lık hız ile gerilim uygulanmış ve bağlanma dayanımları (kg.f) ile kopma şekilleri kaydedilmiştir. Verilerin analizi tek yönlü ANOVA ve t testi ile yapılmıştır (p<0.05). 4-META reçine en yüksek bağlanma dayanımını retansiyon ağı ile (111.33 kg.f/cm2) göstermiş, bu değer kumlanmış grubun değerinden (100.77 kg.f/cm2) istatistiksel olarak farklı bulunmamıştır. 4-META akrilik reçine, yüzeyi kumlanmış ve retansiyon ağı olan gruplarda Meliodent'den anlamlı olarak yüksek bağlanma değerleri göstermiştir. Sonuçlar, 4-META soğuk akrilik reçinenin, iskelet protezlerde retansiyon ağına olduğu kadar kumlanmış metal kaideye de yeterli bağlanma sağlayabileceğini göstermiştir.
8
16

REFERENCES

References: 

prosthodontic adhesives. J Dent Res 1991: 70: 208-10.
3. Atsuta M, Nagata K, Turner DT: Strong composites of di-methylacryfates with 4-methacryloxyethyl trimellitic anhydride -JBiomedMat 1983:17: 679-90.
4. Brown D T, Desjardins R P, Chao E Y S: Fatigue failure in acrylic resin retaining minor connectors. J Prosthet Dent 1987: 58: 329-35.
5. Brudvik JS, Nicholls XI: Soldering of removable partial dentures. J Prosthet Dent 1983:49: 762-5.
6. Chang X, Scherer W, Tauk A, Martini R: Shear bond strength of a 4-META adhesive system. J Prosthet Dent 1992: 67: 42-5.
7. Ferrari N, Cagidiago MC, Borracchini A, Bertelli E: Evaluation of a chemical etching solution for nickel-chromium-beryllium and chromium-cobalt alloys. J Prosthet Dent 1989; 62: 516¬21.
8. Garfield R.E.: An effective method for relining metal-based prostheses with acid-etch technigues. J Prosthet Dent 1984:51: 719-21.
9. Gettleman L, Vrijhoef M M A, Uchiyama Y: Proceeding of the International Symposium on Adhesive Prosthodontics. Printed in the Netherlands by Eurosound Drukkerij BVNijmegen, 1986.
10. Godoy FG, Kaiser DA, Malone WFP, Hubbard G: Shear bond strength of two resin adhesive for acid-etched metal prostheses. J Prosthet Dent 1991: 65: 787-9.
11. Hill G L, Zidan O, Marin O G: Bond strengths of etched base metals: Effects of errors in surface area estimation. J Prosthet Dent\9%6: 56: 41-6.
12. Jacobson T E, Chang J C, Keri P P, Watanabe L G: Bond strength of 4-META acrylic resin denture base to cobalt chromium alloy. J Prosthet Dent 1988:60: 570-6.
13. Xacobson T E: The significance of adhesive denture base itsin.lntjProsthodont 1989: 2:163-72.
14. Livaditis G J, Thompson V P: Etched castings: An improved retentive mechanism for resin-bonded retainers. J Prosthet Dent 1982: 47: 52-8.
15. Matsumura H, Yoshida K, Tanaka T, Atsuta M: Adhesive bonding of Titanium with a Titanate coupler and 4-Meta/MMA-TBB opaque resin. J Dent Res 1990: 69:1614-6.
16. Ohno H, Araki Y, Endo K: A new method for promoting adhesion between precious metal alloys and dental adhesives./ Dent Res 1992: 71: 1326-31.
17. Phillips RW. Skinner's science of dental materials, 9th.ed. Philadelphia: WB Saunders Co 1991: 135-50.
18. Simonsen R, Thompson V, Barra CKG: Etched cast restorations: Clinical and laboratory techniques. Quintessence Publishing Colnc 1983: 42-143.
19.
Şenoca
k M: Temel biyoistatistik, 1. Baskı, Istanbul, Çağlayan Kitapevi, 1990.
16
Ö. Kutay, N. Tosunoğlu
20. Tanaka T, Fujiyama E, Shimizu H, Takaki A, Atsuta M: Surface treatment of non-precious alloys for adhesion-fixed partial dentures. / Prosthet Dent 1986: 55: 456-62.
21. Tanaka T, Nagata K, Takeyama M, Atsuta M and et al. 4-Meta opaque resin a new resin strongly adhesive to nickel chromium alloy J Dent Res 1981: 60: 1697-706.
22. Yoshida K, Matsumura H, Atsuta M: Monomer composition and bond strength of light-cured 4-META opaque resin./ Dent Res 1990:69: 849-51.
23. Zurasky JE, Duke ES: Improved adhesion of denture acrylic resins to base metal alloys. / Prosthet Dent 1987:57: 520-4.

Thank you for copying data from http://www.arastirmax.com