Buradasınız

SİLİKON VE IRREVERSIBLE HİDROKOLLOİD ÖLÇÜ MATERYALLERİNİN BOYUTSAL STABİLİTESİNE ÇEŞİTLİ DEZENFEKTAN MADDELERİN ETKİNLİĞİ

THE EFFICIACY O F SEVERAL DISINFECTANTS ON THE DIMENSIONAL STABILITY OF SILICON AND IRRIVERSIBLE HYDROCOLLOID EXPRESSION MATERIALS

Journal Name:

Publication Year:

Abstract (2. Language): 
The increase in the number of earners of hepatitis and acquired immuno deficiency syndrome (AIDS) viruses has caused alarm for many dentists and dental personel. Effective sterilizing techniques are therefore needed for instruments, prostheses and impressions. Difficulties in sterilizing impression materials have led to chemical disinfection as an alternative. In this study, effect of three different disinfectants were evaluated on the dimensional stability of silicon and irrversible hydrocolloid impression materials. Evaluation of the effect of a 30 min. Immersion irreversible hydorcolloid, light and medium body silicone in selected broad-spectrum disinfectants disclosed minimal changes in the resultant casts as evaluated under the large Toolmaker's Microscope in micron. It is concluded there fore, that immersion disinfection of dental impressions does not effect adversely the resultant casts in regard to construction of dental prostheses. But the best results got from the 2% -sodium hypochlorite.
Abstract (Original Language): 
Hepatit ve AIDS virüs ü taşıyıcılarının son yıllarda artması, dişhekimleri vc yardımcı personel için kullanılan aletlerin, ölçü materyallerinin vc protezlerin etkili sterilizasyonunu gerektirmektedir. Ölçü materyallerinin sterilizasyonundaki zorluklar kimyasal dezenfektanların kullanılmasın] gündeme getirmiştir- Çalışmamızda 3 farklı dezenfektan maddenin silikon ve irreversible hidrokoiloid ölçü materyallerinin boyutsal stabilitesine etkisi incelendi. Irreversible hidrokoiloid, akışkan ve orta kıvam silikonların 30 dakika dezenfektanlarda bekletilme süresi sonunda modellerde oluşan minimal linear değişiklikler, Large Toolmaker's Mikroskop ile mikron düzeyinde incelendi. Kimyasal dezenfektanların kullanılan ölçü materyallerinde klinik olarak kabul edilebilir distorsiyonlara neden olduğu gözlendi. Ancak % 2'lik sodyum hipokloril solüsyonunda boyutsal stabiliteniiı en az değişiklik gösterdiği bulundu
31-35

REFERENCES

References: 

1. Merchant VA, Mc Neight MK, Ciborowski CJ, Molinari JA: Preliminary investigation of a method for disinfection of dental impressions. J Prosthet Dent 1984; 52: 877-9.
2. Herrera SP, Merchant VA. Dimensional stability of dental impressions after immersion disinfection, J Am Dent Assoc 1986; 113: 419-22.
3. Johansen RE, Stackhouse JA. Dimensional changes of elastomers during cold sterilization. J Prosthet Dent 1987; 57: 233-6.
4. Schutt RW. Bactericidal effect of a disinfectant dental stone on irreversible hydrocolSoid impressions and stone casts. J Prosthet Dent 1989; 62: 605 7.
5.
Şahmal
ı S, Saygılı G, Belek S. Silikon ve irreversible hidrokoiloid ölçü materyallerine çeşitli dezenfektan maddelerin etkisi. Mikrobiyoloji Bülteni 1991; 25(4): 360-6.
6.
Saygıl
ı G, Şahmalı S, Şahın E. Silikon ölçü maddelerinde kaşık planlamasının ve materyal retansiyonun boyutsal stabiliteye etkisi. H Ü Dishck Fak Derg 1991; 15: 98-101
7. Langenivaller EM, Aquilino S A, Turner KA, The dimensional stability of elastometric impression materials following disinfection. J Prosthet Dent 1990; 63: 270-6,
8. Leuflg RL, Schoenfeld SE. Gypsum casts as a potential source of a cross contamination. J Prosthet Dent 1983;49:210-1.
9. Drennon DG, Johnson GH, Powell L. The accuracy and efficiacy of disinfection by spray atomization on elastomeric impressions. J Prosthet Dent 1989; 62: 468-75.
10. Minagi S, Yano N, Koshida K, Tsuru H. Prevention of acquired immunodeficiency syndrome and hepatitis B II disinfection method for hydrophilic impression materials. 1987; 58: 462-5.
11. Minagi S, Fukushima K, Maeda N, Satomi K, Ohkawa S, Akagawa Y, Miyake Y, Suginaka H, Tsuru H. Disinfection method for impression materials. Freedom from fear hepatitis B and acquired immunodeficiency Syndrome. J Prosthet Dent 1986; 56: 451-4.
12. Tobias RS, Browne RM, Wilson CA. An in vitro study of the antibacterial and antifungal properties of an irreversible hydrocolloid impression material impregnated with disinfectant. J Prosthet Dent 1989; 62: 601-4.
13. Gordon GE, Johnson GH, Drennon DG. The effect of tray selection on the accuracy of clastomenc impression materials. J Prosthet Dent 1990; 63: 12-5.
14. Walters R. Spurrier S. An effect of tray desing and material retention on the linear dimensional changes in polysulfide impressions. J Prosthet Dent 1990; 63: 277-81.
15. Kern M, Rathmer R, Strub JR, Three-dimensional investigation of the accuracy of impression materials after disinfection, J Prosthet Dent 1993;70:449-56.
16. Hilton TJ, Shwartz RS,Bradiey DV, Immersion disinfection of irreversible hydrocolloid impressions Part 2: Effects on Gypsum Casts int: J Proshodont 1994; 7: 424-33.
17. Mitchell JV, Damele JJ.Influencc of tray design upon elastic impression materials. J Prosthet Dent 1970; 23: 51-7.
18. Schwartz RS, Bradley DV, Hilton TJ, Kruse SK. Immersion disinfection of irreversible hydrocolloid impressions. Part I. Microbiology Int J Prosthodont 1994; 7: 418-21.