DEZENFEKSIYON VE STERILIZAS YON UN SİLİKON ESASLI ÖLÇÜ MADDELERİNİN BOYUTSAL DEĞİŞİMLERİNE ETKİLERİ

THE EFFECT OF DISINFECTION AND STERILIZATION ON THE DIMENSIONAL CHANGES OF SILICONE-BASED IMPRESSION MATERIALS

Journal Name:

Publication Year:

Abstract (2. Language): 
The dimensional changes of condensation (Thixoflex) and addition silicone (Baysilex) impression materials were investigated under following 5 different testing conditions: % 0.05 sodium hypoclorite, % 2 glutaraldehyde, microwave energy, deionized water and room temparaiu-re. A die recommended for ADA no. 19 was used to prepare. 25 specimens which were divided into 5 test groups for each material. Time-dependent measurements were performed with a Gaertner microscope qraduated in 0.01 mm increments and compared with the dimensions of the standard brass die using Student t test (p<0.05). Thixoflex showed significant dimensional variability when disinfected with sodium hypoclorite. and microwave energy, while no significance observed after testing with glutaraldehyde. The dimensional change of Baysilex was not significant under all testing conditions. It was concluded that Thixoflex and Baysilex silicone impression materials can be disinfected using glutaraldehyde without significant dimensional change.
Abstract (Original Language): 
Çalışmamızda kondansasyon silikonu Thixoflex'in ve ilave polimerizasyon silikonu Baysilex'in boyutsal değişimleri % 0.05'lik sodyumhipoklorit'te, % 2'lik gluteralde-hit'te, mikrodalga enerjisinde, 37°C distile suda ve oda şartlarında incelenmiştir. Her bir ölçü maddesi için bir grupta 5 örnek olmak üzere 5 deney grubunda 25 Örnek ADA 19 no.lu spesifİkasyona uygun bir kalıpta hazırlanmıştır. Ölçümler 0.01 mm aralıklarla derecelendirilmiş bir Gaertner mikroskobu ile zamana bağlı olarak ölçülmüştür. Elde edilen değerler standart kalıbın boyutuyla t testine göre karşı-laştırılmıştır. Thixoflex'in sodyumhipoklorit ve mikrodalga enerjisi ile dezenfeksiyonu yapıldığında meydana gelen boyutsal değişimi anlamlı olmasına rağmen, gluteraldehit solüsyonu içindeki boyutsal değişimi istatistiksel olarak anlamlı bulunmamıştır. Baysilex ise hiçbir deney ajanında anlamlı boyutsal değişiklik göstermemiştir. Sonuç olarak gluteraldehit'in Thixoflex ve Baysilex silikon ölçü maddelerinin boyutsal değişimine sebep olmadan kullanılabileceği saptanmıştır.
181
186

REFERENCES

References: 

1. Counsil on Dental Materials and Devices: Revised American Dental Association Specification No.19 for Non-Aqueous, Elastomeric Dental Impression Materials. J. Am. Dent. Assoc., 1977;94:733-41.
2.
Arat
, E., Tuncer, N., Külckçi, G.: Dezenfektan bir madde içeren yeni bir aljinatın antimikrobial etkisi ve alçı modellerde çapraz bulaşmayı önlemesi. İ.Ü. Dİş Hek. Fak. Der. 1991; 25; 69-73.
3. Council on Dental Materials and Devices Council on Dental Therapeutics Infection Control in The Dental Office. J. Am. Dent. Assoc., 1978; 97: 673-7.
4.
Çakaloğlu
, Y„ Ökten, A., Yalçın, S.: Türkiye'de Hepatit B virüsü enfeksiyonu seroepidemiyolojisi (Taşiyicilık-seropozİtİf-lik prevalansı). The Turkish Journal of Gastroenterohepato-logy, 1990; 1: 49-43.
5. Durr, D.P., Novak, E.V.: Dimensional stability of alginate impressions immersed in disinfecting solutions. /. Dent. For Child., 1987;54: 45-48.
6. Herrera, S.P., Merchant, V.A.: Dimensional stability of dental impression after immersion disinfection. J. Am. Dent. Assoc. 1986; 713:419-22.
7. Kutay,
Ö.
, Bilgin, T., Şakar, O.: Katalizör oranı arttınlan kondansasyon siiikonu ölçü maddelerinin boyutsal değişimi. İ.Ü. Diş Hek. Fak. Dergisi, 1993; 27: 131-37.
8.
Külekçi
, G., Balkanlı, O., İnanç, D., Güvener, Z.: Dişhc-kimliğinde Hepatit B seroprevalans. Türk Mikrobİyol. Cem. Derg., 1991; 21: 109-17.
9. Langenwalter, E.M., Aquilino, S.A., Turner, K.A.; The dimensional stability of elastomeric impression materials following disinfection. J. Prosthet. Dent. 1990; 63: 270-6.
10. Leung, R.L., Schonfeld, S.E.: Gypsum casts as a potential source of microbial cross-contamination. J. Prosthet. Dent. 1983;-/?: 210-11.
11. Matyas, J., Dao, N., Caputa, A.A., Lucatoto, M.: Effects of disinfectans on dimensional accuracy of impression materials. J. Prosthet. Dent. 1990; 64: 25-31.
12. McCornıick, R.J., Watts, D.C., Wilson, H.F.: Effects of a succinicaldehyde on clastromeric impression. /. Dent. 1989; 17: 246-49.
13. Merchant, V.A., Radcliffe, R.M., Herrera, S.P., Stroster, T.G.: Dimensional stability of reversible hydrocolioid impressi-
186
T, Bilgin, O. Kutay, O. İnce
ons
immerse
d in selected disinfectant solutions./. Am. Dent. Assoc. 1989; 119:533-5.
14. Olsson, S., Bergman, B.O., Bergman, M.: Agar impression materials: Dimensional stability and surface detail sharpness following treatment with disinfectant solutions. Swed. Dent. J., 1987;22: 169-77.
15. Phillips, R.W.: Skinner's Science of dental materials, 9th. ed., Philadelphia, WB Saunders Co., 1991; 135-50.
16. Rohrer, M.D., Bulard, R.A.: Microwave Sterilization. J. Am. Dent. Assoc., 1985;220:194-8.
17. Songer, R.G., Bradford, B.A., Elaney, J.M.: An Inquiry into
the sterilization of dental handpieces relative to transmission of Hepatitis B virus./. Am. Dent. Assoc. 1978; 96: 621-4.
18. Storer, R., McCabe, J.F.: An investigation of methods available for sterilising impressions. Brit. Dent. J., 1981; 252:217¬19.
19. Tuliner, J.B., Commette, J.A., Moon, H.C.: Linear dimensional changes İn dental impression after immersion in disinfectant solutions. J. Prosthet. Dent. 1988; 60: 725-8.
20. Tuncer, N.,
Külekçİ
, G., Tüfekçİoğlu, B. ve ark.: Alçı modellerle çapraz bulaşmanın önlenmesinde mikrodaîga sterilizasyonun etkinliği. Dişhekimliğinde Klinik, 1990; 3: 45-47.

Thank you for copying data from http://www.arastirmax.com