You are here

FARKLI METAL ALAŞIMLARDAN HAZIRLANAN METAL DESTEKLİ PORSELENLERDE MİKROSIZINTI

MICRO LEAKAGE STUDY OF PORCELAIN FUSED TO METAL ALLOYS

Journal Name:

Publication Year:

Keywords (Original Language):

Abstract (2. Language): 
The present article reports a study ofmicroleakage in the interface between various metal alloys and porcelain. In this study chrome-nickel, chrome-cobalt and titanium alloys were investigated. Microleakage specimen were prepared in the shape $2.2 mm thick disks which were 1 cm in diameter. Our findings showed similar microleakage in specimen stored in water and those not stored in water. The results indicated that microleakage at porcelain fused to chrome-cobalt alloy was greater than that found for the other two alloys. No significant differences were found between the microleakage at the intetface of porcelain fused to titanium and porcelain fused to chrome nickel alloy.
Abstract (Original Language): 
Çalışmada metal destekli porselen ara yüzeyinde mikrosızıntı incelenmiştir. Bunun için krom-kobalf, kromnikel ve titanyum alaşımlarından 1 cm çapında, lmm metal kalınlığı ve 1.2 mm porselen kalınlığı olan 20'şer adet örnek hazırlanmıştır. Sızıntı belirlemesinde oforadyografi yöntemi kullanılmıştır. Her alaşım grubundaki örnekler suda beklemiş ve beklememiş olmak üzere ikiye ayrılmıştır. Çalışmanın sonucunda suda beklemiş ve beklememiş örneklerin sızıntıları arasında önemsiz fark olduğu bulunmuştur. En fazla sızıntı krom-kobalt destekli porselen örneklerde gözlenmiştir. Krom-nikel ve titanyum destekli porselen örnekler arasında ise mikrosızıntı farkı önemsiz bulunmuştur.
125
128

REFERENCES

References: 

1- Akagi K, Okamoto Y, Matsuura T, Horibe T: Properties of test metal ceramic titanium. / Prosthet Dent 1992: 6*462-467.
2- Bowers J, Vermilyea S G, Griswold W H: Effect of metal conditioners on porcelain - alloy bond strength./Prosthet Dent 1985: 5*201-203.
3- Chambless A L, Long J L, HembreeJH, Staffanou R & Leakage of various types alloys at the porcelain-metal interface. IneJProst 1988: /.-47-50.
4- Gilbert J, Covey D, Lautenschlager E: Bond characteristics of porcelain fused to milled titanium. Dent Mater 1994: 10:134-140.
5- Jochen D G, Caputo A A, MatyasJ: Effect of metal surface treatment on ceramic bond strength. J Prosthet Dent 1986: 55:186-188.
6- Jones R S, Moore K, Goordace J C, Munoz-Viveros C A: Microleakage and shear bond strength of resin and porcelain veneers bonded to cast alloys. / Prosthet Dent 1991: 65:221-228.
7- Kıdd E A M: Microleakage. A review. J Dent 1976: 4:199-206.
8- Malhotra M L, Maickel L B: Sheare bond strength in porcelain-metal restorations. J Prosthet Dent 1980: «:397-400.
9- Sorensen J A, Rang S K, Avera S P: Porcelain-composite interface microleakage with various porcelain surface treatment. Dent Mater i 99 i: 7:118-123.
10- Staffanou S R, Hembree H J. Rivers AJ, Myers L M, Kİlgore J L: Leakage study of three veneering materials./ Prosthet Dent 1985: 54:204-206.
11- Tjan A H L, Peach K D, Vanderburgh S L, Zbarasc-huk E R: Microleakage of crowns cemented with glass iono-mer cement. Effect of preparation finish and conditioning with polyacrylic acid. J Prosthet Dent 1991: 66:602-606.
12- WuY, MoserJB,JamesonL M, Molone W F P:The effect of oxidation heat treatment on povcelan bond strength in selected base metal alloys. J Prosthet Dent 1991: 66.439¬444.